Changes for page 4.1 Signals

Last modified by Admin on 2025/02/11 17:36

From version 2.4
edited by Admin
on 2024/12/26 15:59
Change comment: There is no comment for this version
To version 2.3
edited by Admin
on 2024/12/11 11:33
Change comment: Update document after refactoring.

Summary

Details

Page properties
Content
... ... @@ -10,7 +10,25 @@
10 10  
11 11  In this section:
12 12  
13 -* Input #1 - Input #8 – states of the inputs1-4 respectively.
13 +* Battery cover – a signal from the battery cover;
14 +* Charger connected – a signal indicating that charger is connected;
15 +* Power up/down request – a request to power down the device;
16 +* Inhibit charging – a command to open the charging contactor;
17 +* Inhibit discharging – a command to open the discharging contactor;
18 +* CH contactor feedback – a signal from charging contactor feedback loop;
19 +* DCH contactor feedback – a signal from discharging contactor feedback loop;
20 +* Insulation status – a signal from an insulation monitoring device;
21 +* Charge request – a request to close the charging contactor;
22 +* Precharge request – a request to close the precharging contactor;
23 +* Discharge request – a request to close the discharging contactor;
24 +* PCH contactor feedback – a signal from precharging contactor feedback loop;
25 +* CH/DCH contactor feedback – a signal from charging/discharging contactor feedback loop;
26 +* Main contactor feedback – a signal from main contactor feedback loop;
27 +* Interlock – a signal from interlock loop;
28 +* Fuse 1, Fuse 2, Fuse 3 – signals from fuses;
29 +* Circuit breaker status – status of protection disconnector;
30 +* Balancing request – a request to balance the cells;
31 +* Close Main contactor – a request to close the main contactor.
14 14  
15 15  The states of the discrete output signals are available in the "Signals → Output discrete signals" section:
16 16