Changes for page 4.1 Signals

Last modified by Admin on 2025/02/11 17:36

From version 2.4
edited by Admin
on 2024/12/26 15:59
Change comment: There is no comment for this version
To version 1.1
edited by Admin
on 2024/12/05 12:48
Change comment: There is no comment for this version

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -Battery management systems.BMS Main 3.4\. Monitoring.WebHome
1 +drafts.bms-main-3.4\. Monitoring.WebHome
Content
... ... @@ -1,8 +1,8 @@
1 1  (% data-numbered-headings-start="4" style="--numbered-headings-start: 3;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 -= Monitoring =
2 += Settings =
3 3  
4 4  (% data-numbered-headings-start="1" style="--numbered-headings-start: 0;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
5 -== Signals ==
5 +== Inputs and outputs ==
6 6  
7 7  States of the device's discrete inputs are available in the "Signals → Input discrete signal" section:
8 8  
... ... @@ -10,8 +10,27 @@
10 10  
11 11  In this section:
12 12  
13 -* Input #1 - Input #8 – states of the inputs1-4 respectively.
13 +* Battery cover – a signal from the battery cover;
14 +* Charger connected – a signal indicating that charger is connected;
15 +* Power up/down request – a request to power down the device;
16 +* Inhibit charging – a command to open the charging contactor;
17 +* Inhibit discharging – a command to open the discharging contactor;
18 +* CH contactor feedback – a signal from charging contactor feedback loop;
19 +* DCH contactor feedback – a signal from discharging contactor feedback loop;
20 +* Insulation status – a signal from an insulation monitoring device;
21 +* Charge request – a request to close the charging contactor;
22 +* Precharge request – a request to close the precharging contactor;
23 +* Discharge request – a request to close the discharging contactor;
24 +* PCH contactor feedback – a signal from precharging contactor feedback loop;
25 +* CH/DCH contactor feedback – a signal from charging/discharging contactor feedback loop;
26 +* Main contactor feedback – a signal from main contactor feedback loop;
27 +* Interlock – a signal from interlock loop;
28 +* Fuse 1, Fuse 2, Fuse 3 – signals from fuses;
29 +* Circuit breaker status – status of protection disconnector;
30 +* Balancing request – a request to balance the cells;
31 +* Close Main contactor – a request to close the main contactor.
14 14  
33 +
15 15  The states of the discrete output signals are available in the "Signals → Output discrete signals" section:
16 16  
17 17  [[image:1733402780555-886.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="146" width="800"]]
... ... @@ -20,6 +20,7 @@
20 20  
21 21  * Output #1 - Output #4 – states of the outputs 1-4 respectively.
22 22  
42 +
23 23  The states of the power switches are available in the "Signals → Power switches" section:
24 24  