... ... @@ -4,6 +4,8 @@
4 4  (% data-numbered-headings-start="1" style="--numbered-headings-start: 0;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
5 5  == Signals ==
6 6  
7 +States of the KEYRUN and CHARGE_ON signals are available in the "Signals" section.
8 +
7 7  States of the device's discrete inputs are available in the "Signals → Input discrete signal" section:
8 8  
9 9  [[image:1733402780551-891.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="448" width="800"]]
... ... @@ -10,25 +10,7 @@
10 10  
11 11  In this section:
12 12  
13 -* Battery cover – a signal from the battery cover;
14 -* Charger connected – a signal indicating that charger is connected;
15 -* Power up/down request – a request to power down the device;
16 -* Inhibit charging – a command to open the charging contactor;
17 -* Inhibit discharging – a command to open the discharging contactor;
18 -* CH contactor feedback – a signal from charging contactor feedback loop;
19 -* DCH contactor feedback – a signal from discharging contactor feedback loop;
20 -* Insulation status – a signal from an insulation monitoring device;
21 -* Charge request – a request to close the charging contactor;
22 -* Precharge request – a request to close the precharging contactor;
23 -* Discharge request – a request to close the discharging contactor;
24 -* PCH contactor feedback – a signal from precharging contactor feedback loop;
25 -* CH/DCH contactor feedback – a signal from charging/discharging contactor feedback loop;
26 -* Main contactor feedback – a signal from main contactor feedback loop;
27 -* Interlock – a signal from interlock loop;
28 -* Fuse 1, Fuse 2, Fuse 3 – signals from fuses;
29 -* Circuit breaker status – status of protection disconnector;
30 -* Balancing request – a request to balance the cells;
31 -* Close Main contactor – a request to close the main contactor.
15 +* Input #1 - Input #8 – physical states of the inputs 1-4 respectively.
32 32  
33 33  The states of the discrete output signals are available in the "Signals → Output discrete signals" section:
34 34  
... ... @@ -36,7 +36,7 @@
36 36  
37 37  In this section:
38 38  
39 -* Output #1 - Output #4 – states of the outputs 1-4 respectively.
23 +* Output #1 - Output #4 – physical states of the outputs 1-4 respectively.
40 40  
41 41  The states of the power switches are available in the "Signals → Power switches" section:
42 42  
... ... @@ -44,7 +44,7 @@
44 44  
45 45  In this section:
46 46  
47 -* Power switch #1 - Power switch #6 – states of the Power switches 1-6 respectively.
31 +* Power switch #1 - Power switch #6 – physical states of the power switches 1-6 respectively.