Changes for page 4.1 Signals
Last modified by Admin on 2025/02/11 17:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,6 +4,8 @@ 4 4 (% data-numbered-headings-start="1" style="--numbered-headings-start: 0;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 5 == Signals == 6 6 7 +States of the KEYRUN and CHARGE_ON signals are available in the "Signals" section. 8 + 7 7 States of the device's discrete inputs are available in the "Signals → Input discrete signal" section: 8 8 9 9 [[image:1733402780551-891.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="448" width="800"]] ... ... @@ -10,25 +10,7 @@ 10 10 11 11 In this section: 12 12 13 -* Battery cover – a signal from the battery cover; 14 -* Charger connected – a signal indicating that charger is connected; 15 -* Power up/down request – a request to power down the device; 16 -* Inhibit charging – a command to open the charging contactor; 17 -* Inhibit discharging – a command to open the discharging contactor; 18 -* CH contactor feedback – a signal from charging contactor feedback loop; 19 -* DCH contactor feedback – a signal from discharging contactor feedback loop; 20 -* Insulation status – a signal from an insulation monitoring device; 21 -* Charge request – a request to close the charging contactor; 22 -* Precharge request – a request to close the precharging contactor; 23 -* Discharge request – a request to close the discharging contactor; 24 -* PCH contactor feedback – a signal from precharging contactor feedback loop; 25 -* CH/DCH contactor feedback – a signal from charging/discharging contactor feedback loop; 26 -* Main contactor feedback – a signal from main contactor feedback loop; 27 -* Interlock – a signal from interlock loop; 28 -* Fuse 1, Fuse 2, Fuse 3 – signals from fuses; 29 -* Circuit breaker status – status of protection disconnector; 30 -* Balancing request – a request to balance the cells; 31 -* Close Main contactor – a request to close the main contactor. 15 +* Input #1 - Input #8 – physical states of the inputs 1-4 respectively. 32 32 33 33 The states of the discrete output signals are available in the "Signals → Output discrete signals" section: 34 34 ... ... @@ -36,7 +36,7 @@ 36 36 37 37 In this section: 38 38 39 -* Output #1 - Output #4 – states of the outputs 1-4 respectively. 23 +* Output #1 - Output #4 – physical states of the outputs 1-4 respectively. 40 40 41 41 The states of the power switches are available in the "Signals → Power switches" section: 42 42 ... ... @@ -44,7 +44,7 @@ 44 44 45 45 In this section: 46 46 47 -* Power switch #1 - Power switch #6 – states of the Power switches 1-6 respectively.31 +* Power switch #1 - Power switch #6 – physical states of the power switches 1-6 respectively. 48 48 49 49 === Current sensor === 50 50
- 1739295295106-897.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +26.8 KB - Content