Wiki source code of 4.1 Signals

Last modified by Admin on 2025/02/11 17:36

Show last authors
1 (% data-numbered-headings-start="4" style="--numbered-headings-start: 3;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 = Monitoring =
3
4 (% data-numbered-headings-start="1" style="--numbered-headings-start: 0;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
5 == Signals ==
6
7 States of the KEYRUN and CHARGE_ON signals are available in the "Signals" section.
8
9 States of the device's discrete inputs are available in the "Signals → Input discrete signal" section:
10
11 [[image:1739295295106-897.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="200" width="800"]]
12
13 In this section:
14
15 * Input #1 - Input #8 – physical states of the inputs 1-4 respectively.
16
17 The states of the discrete output signals are available in the "Signals → Output discrete signals" section:
18
19 [[image:1739295317402-295.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="159" width="800"]]
20
21 In this section:
22
23 * Output #1 - Output #4 – physical states of the outputs 1-4 respectively.
24
25 The states of the power switches are available in the "Signals → Power switches" section:
26
27 [[image:1739295355873-803.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="169" width="800"]]
28
29 In this section:
30
31 * Power switch #1 - Power switch #6 – physical states of the power switches 1-6 respectively.
32
33 === Current sensor ===
34
35 The states of the current sensors are available in the "Signals → Current sensor" section:
36
37 [[image:1733402780557-330.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="217" width="800"]]
38
39 In this section:
40
41 * Sensor 1, 2, 3: IN1 – output signal from the current sensor, V;
42 * Sensor 1, 2, 3: REF_IN2 – signal in the reference line, V;
43 * Sensor 1, 2, 3: Value – calculated value of the current, A;
44 * Sensor 1, 2, 3: Low range – calculated value of the lower range current, A.
45
46 === Shunt sensor ===
47
48 The state of the shunt sensor is available in the "Signals → Shunt sensor" section:
49
50 [[image:1733402780565-376.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="120" width="800"]]
51
52 In this section:
53
54 * Online – a flag showing that the communication with the BMS Current Sensor is established;
55 * Errors – a list of internal errors of the shunt sensor;
56 * Current – an instantaneous value of current measured by the BMS Current Sensor, A (measuring frequency is 50 Hz);
57 * Current (mean) – a mean value of current measured by the BMS Current Sensor, A (the value is calculated as an average of 100 consistent measurements);
58 * Temperature – a temperature of the shunt sensor, °C.
59
60 === HVIL ===
61
62 The state of the HVIL is available in the "Signals → HVIL" section:
63
64 [[image:1733402780566-996.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="95" width="800"]]
65
66 In this section:
67
68 * Current (power off) – high voltage interlock loop current at power off, A;
69 * Current (power on) – high voltage interlock loop current at power on, A.