Changes for page 3.5 External equipment

Last modified by Admin on 2025/06/19 12:32

From version 9.6
edited by Admin
on 2024/12/26 15:47
Change comment: There is no comment for this version
To version 14.1
edited by Admin
on 2024/12/26 16:44
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -386,12 +386,16 @@
386 386  * Warranty cycles;
387 387  * Warranty hours;
388 388  * Warranty usable energy, Wh;
389 -* Total
390 -* Total
391 -* Total
389 +* Total energy + (initial value), Wh;
390 +* Total energy - (initial value), Wh;
391 +* Total energy regen (initial value), Wh;
392 392  * Hours in service;
393 -*
393 +* Battery brand;
394 +* Battery ID;
395 +* Battery serial number.
394 394  
397 +TBA
398 +
395 395  (% class="box infomessage" %)
396 396  (((
397 397  **Note:** Dependence of the thermal derate from the battery and contactor temperature is linear. The system sends maximum value of the thermal derate among values calculated for the battery temperature and contactor temperature.
... ... @@ -437,7 +437,7 @@
437 437  
438 438  To change communication parameters with a Spirit AeroSystems truck, select the "External equipment → Trucks and Vehicles → Spirit AGV" section:
439 439  
440 -[[image:1733330972257-158.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="182" width="800"]]
444 +[[image:1735228139582-964.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="800"]]
441 441  
442 442  In this section:
443 443  
... ... @@ -450,8 +450,6 @@
450 450  ** V2;
451 451  * Node ID – a BMS identifier in the CANopen network;
452 452  * Receive timeout – a timeout for receiving packets from the truck (if no data is being received from the truck during this time, the “Spirit offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Spirit offline" error does not occur;
453 -* Inhibit charging on the "Spirit offline" error – a flag to forbid charging if the "Spirit offline" error is generated;
454 -* Inhibit discharging on the "Spirit offline" error – a flag to forbid discharging if the "Spirit offline" error is generated;
455 455  * SOC: Limited operation – a SOC level, at which the truck goes into a state of limited functionality, %;
456 456  * SOC: Lift lockout – a SOC level, at which the truck locks the lift, %;
457 457  * Send Heartbeat messages– a flag to enable generation of the Heartbeat messages to the truck;
... ... @@ -467,7 +467,7 @@
467 467  
468 468  To change communication parameters with the BMS Crown adapter, select the "External equipment → Trucks and Vehicles → Crown truck" section:
469 469  
470 -[[image:1733330972258-463.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="96" width="800"]]
472 +[[image:1735228176135-223.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="92" width="800"]]
471 471  
472 472  In this section:
473 473  
... ... @@ -477,7 +477,7 @@
477 477  ** CAN2 (int);
478 478  * Node ID – a BMS Crown identifier in the CANopen network;
479 479  * Delta voltage (tolerance) – a maximum deviation between the battery voltage and the voltage output by the Crown forklift system, V;
480 -* Inhibit discharging on the EWS signal – a flag to inhibit reclosing the discharging contactor after sending EWS signal to the forklift.
482 +* Prevent discharging on the EWS signal – a flag to inhibit reclosing the discharging contactor after sending EWS signal to the forklift.
481 481  
482 482  When working with the Crown forklift, the algorithm for controlling the discharging contactor is changed. The state machine used to switch the discharging contactor is described below.
483 483  
... ... @@ -641,9 +641,11 @@
641 641  
642 642  Communication parameters with the Main X are configured in the "External equipment → BMS → Main X" section:
643 643  
644 -[[image:1733330996006-677.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="106" width="800"]]
646 +[[image:1735228238119-343.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="82" width="800"]]
645 645  
646 646  In this section:
647 647  
648 648  * Enable – a flag to enable communication with the BMS Main X;
649 -* Receive timeout – a timeout for receiving packets from the BMS Main X (if no data is being received from the BMS Main X during this time, the “Inhibit charging“ and “Inhibit discharging” signals may be generated), millisecond.
651 +* Receive timeout – a timeout for receiving packets from the BMS Main X (if no data is being received from the BMS Main X during this time, the “Inhibit charging“ and “Inhibit discharging” signals may be generated), millisecond;
652 +* Set the 'Inhibit charging' signal if BMS Main X is offline;
653 +* Set the 'Inhibit discharging' signal if BMS Main X is offline;
1735228139582-964.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +29.3 KB
Content
1735228176135-223.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +18.0 KB
Content
1735228238119-343.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +17.6 KB
Content