... ... @@ -371,18 +371,18 @@
371 371  * Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to the forklift;
372 372  * Heartbeat period – Heartbeat sending period, millisecond;
373 373  * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “HYG offline“ flag is set), millisecond; at a value of 0 milliseconds, the "HYG offline" error does not occur;
374 -* Prevent discharging on the “Charger connected” signal and the "HYG offline" error – a flag to forbid discharging if the “Charger connected” signal presents and "HYG offline" error is generated;
374 +* Inhibit charging on the "HYG offline" error – a flag to forbid charging if the "HYG offline" error is generated;
375 +* Inhibit discharging on the "HYG offline" error – a flag to forbid discharging if the "HYG offline" error is generated;
376 +* Prevendischarging on the “Charger connected” signal and the "HYG offline" error – a flag to forbid discharging if the “Charger connected” signal presents and "HYG offline" error is generated;
375 375  * Maximum voltage, V;
376 376  * Minimum voltage, V;
377 377  * Maximum charge current, А;
378 378  * Maximum discharge current, А;
379 -* SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %;
380 380  * SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %;
382 +* SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %;
383 +* Thermal derate (0%): Battery temperature - a value of the battery temperature at which the thermal derate starts, °C;
381 381  * Thermal derate (0%): Contactor temperature - a value of the contactor temperature at which the thermal derate starts, °C;
382 -* Thermal derate (0%): High battery temperature - a value of the high battery temperature at which the thermal derate starts, °C;
383 -* Thermal derate (0%): Low battery temperature - a value of the low battery temperature at which the thermal derate starts, °C;
384 -* Nominal battery voltage, V;
385 -* Warran
385 +*
386 386  
387 387  (% class="box infomessage" %)
388 388  (((