Changes for page 3.5 External equipment
Last modified by Admin on 2025/06/19 12:32
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -Battery management systems.BMS Main 3.3\. Configuration.WebHome1 +Battery management systems.BMS Main 3.3\. Settings.WebHome - Content
-
... ... @@ -93,7 +93,7 @@ 93 93 94 94 (% class="box warningmessage" %) 95 95 ((( 96 -**Warning! **To work properly with the charger, it is necessary to turn on sending synchronization messages over the CANopen network (see [[CAN1>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.6 Connectivity.WebHome||anchor="HCAN1"]]).96 +**Warning! **To work properly with the charger, it is necessary to turn on sending synchronization messages over the CANopen network (see [[CAN1>>doc:Battery management systems.BMS Main 3.3\. Settings.3\.6 Connectivity.WebHome||anchor="HCAN1"]]). 97 97 ))) 98 98 99 99 (% class="box infomessage" %) ... ... @@ -355,7 +355,7 @@ 355 355 356 356 To change communication parameters with HYG Class I-III equipment, select the "External equipment → Trucks and Vehicles → HYG Class I-III truck" section: 357 357 358 -[[image:1735 227832802-527.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="337" width="800"]]358 +[[image:1733330959808-973.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="234" width="800"]] 359 359 360 360 In this section: 361 361 ... ... @@ -368,12 +368,10 @@ 368 368 ** II-III; 369 369 ** I-III Gen.2; 370 370 * Node ID – an equipment identifier in the CANopen network; 371 -* Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to the forklift; 372 -* Heartbeat period – Heartbeat sending period, millisecond; 373 373 * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “HYG offline“ flag is set), millisecond; at a value of 0 milliseconds, the "HYG offline" error does not occur; 374 374 * Inhibit charging on the "HYG offline" error – a flag to forbid charging if the "HYG offline" error is generated; 375 375 * Inhibit discharging on the "HYG offline" error – a flag to forbid discharging if the "HYG offline" error is generated; 376 -* Prevent discharging on the “Charger connected” signal and the "HYG offline" error – a flag to forbid discharging if the “Charger connected” signal presents and "HYG offline" error is generated;374 +* Inhibit discharging on the “Charger connected” signal and the "HYG offline" error – a flag to forbid discharging if the “Charger connected” signal presents and "HYG offline" error is generated; 377 377 * Maximum voltage, V; 378 378 * Minimum voltage, V; 379 379 * Maximum charge current, А; ... ... @@ -382,7 +382,8 @@ 382 382 * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %; 383 383 * Thermal derate (0%): Battery temperature - a value of the battery temperature at which the thermal derate starts, °C; 384 384 * Thermal derate (0%): Contactor temperature - a value of the contactor temperature at which the thermal derate starts, °C; 385 -* 383 +* Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to the forklift; 384 +* Heartbeat period – Heartbeat sending period, millisecond. 386 386 387 387 (% class="box infomessage" %) 388 388 (((
- 1735227832802-527.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -68.1 KB - Content