Changes for page 3.5 External equipment
Last modified by Admin on 2025/06/19 12:32
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - Battery managementystems.BMS MainConfiguration.WebHome1 +drafts.bms-main-3.3\. Settings.WebHome - Content
-
... ... @@ -1,16 +1,16 @@ 1 -(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Settings = 1 + 3 3 4 -(% data-numbered-headings-start="5" style="--numbered-headings-start: 4;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 -== External equipment == 6 6 7 -The BMS Main 3 device 4 +The BMS Main 3 device supports joint operation with chargers, inverters, indication panels, trucks and vehicle controllers. 8 8 9 -=== J1939 charger === 10 10 7 +1. 8 +11. 9 +111. J1939 charger 10 + 11 11 To change the parameters of communication with a charger using J1939 protocol, select the "External equipment → Chargers → J1939 charger" section: 12 12 13 -[[image:1733330925860-611.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="191" width="800"]]13 +[[image:1733330925860-611.png]] 14 14 15 15 In this section: 16 16 ... ... @@ -41,13 +41,16 @@ 41 41 42 42 Algorithm for working with the charger: 43 43 44 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main3.3\.Configuration.3\.3 Control.WebHome||anchor="HCharge"]]).44 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11). 45 45 46 -=== Eltek charger === 47 47 47 +1. 48 +11. 49 +111. Eltek charger 50 + 48 48 To change the communication parameters with an Eltek charger, select the "External equipment → Chargers → Eltek charger" section: 49 49 50 -[[image:1733330925864-261.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="129" width="800"]]53 +[[image:1733330925864-261.png]] 51 51 52 52 In this section: 53 53 ... ... @@ -64,13 +64,16 @@ 64 64 65 65 Algorithm for working with the charger: 66 66 67 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main3.3\.Configuration.3\.3 Control.WebHome||anchor="HCharge"]]).70 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11). 68 68 69 -=== MicroPower charger === 70 70 73 +1. 74 +11. 75 +111. MicroPower charger 76 + 71 71 To change the parameters of communication with a MicroPower charger, select the "External equipment → Chargers → MicroPower charger" section: 72 72 73 -[[image:1733330925865-294.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="149" width="800"]]79 +[[image:1733330925865-294.png]] 74 74 75 75 In this section: 76 76 ... ... @@ -89,23 +89,20 @@ 89 89 90 90 Algorithm for working with the charger: 91 91 92 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main3.3\.Configuration.3\.3 Control.WebHome||anchor="HCharge"]]).98 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11). 93 93 94 -(% class="box warningmessage" %) 95 -((( 96 -**Warning! **To work properly with the charger, it is necessary to turn on sending synchronization messages over the CANopen network (see [[CAN1>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.6 Connectivity.WebHome||anchor="HCAN1"]]). 97 -))) 100 +**Warning! To work properly with the charger, it is necessary to turn on sending synchronization messages over the CANopen network (see section 2.5.2).** 98 98 99 -(% class="box infomessage" %) 100 -((( 101 -After changing the settings, restart the BMS Main 3 device. 102 -))) 102 +**After changing the settings, restart the BMS Main 3 device.** 103 103 104 -=== S.P.E. charger === 105 105 105 +1. 106 +11. 107 +111. S.P.E. charger 108 + 106 106 To change the parameters of communication with an S.P.E. charger, select the "External equipment → Chargers → SPE charger" section: 107 107 108 -[[image:1733330934850-187.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="120" width="800"]]111 +[[image:1733330934850-187.png]] 109 109 110 110 In this section: 111 111 ... ... @@ -121,13 +121,16 @@ 121 121 122 122 Algorithm for working with the charger: 123 123 124 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main3.3\.Configuration.3\.3 Control.WebHome||anchor="HCharge"]]).127 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11). 125 125 126 -=== Bassi charger === 127 127 130 +1. 131 +11. 132 +111. Bassi charger 133 + 128 128 To change the parameters of communication with a Bassi charger, select the "External equipment → Chargers → Bassi charger" section: 129 129 130 -[[image:1733330934853-223.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]136 +[[image:1733330934853-223.png]] 131 131 132 132 In this section: 133 133 ... ... @@ -144,18 +144,18 @@ 144 144 145 145 Algorithm for working with the charger: 146 146 147 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main3.3\.Configuration.3\.3 Control.WebHome||anchor="HCharge"]]).153 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11). 148 148 149 -(% class="box infomessage" %) 150 -((( 151 -After changing the settings, restart the BMS Main 3 device. 152 -))) 155 +**After changing the settings, restart the BMS Main 3 device.** 153 153 154 -=== ATIB charger === 155 155 158 +1. 159 +11. 160 +111. ATIB charger 161 + 156 156 To change the parameters of communication with an ATIB Elettronica charger, select the "External equipment → Chargers → ATIB Elettronica charger" section: 157 157 158 -[[image:1733330934855-541.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="116" width="800"]]164 +[[image:1733330934855-541.png]] 159 159 160 160 In this section: 161 161 ... ... @@ -171,18 +171,17 @@ 171 171 172 172 Algorithm for working with the charger: 173 173 174 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main3.3\.Configuration.3\.3 Control.WebHome||anchor="HCharge"]]).180 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11). 175 175 176 -(% class="box infomessage" %) 177 -((( 178 -After changing the settings, restart the BMS Main 3 device. 179 -))) 182 +**After changing the settings, restart the BMS Main 3 device.** 180 180 181 -=== Fronius charger === 184 +1. 185 +11. 186 +111. Fronius charger 182 182 183 183 To change the parameters of communication with a Fronius charger, select the "External equipment → Chargers → Fronius charger" section: 184 184 185 -[[image:1733330947593-954.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="139" width="800"]]190 +[[image:1733330947593-954.png]] 186 186 187 187 In this section: 188 188 ... ... @@ -200,18 +200,18 @@ 200 200 201 201 Algorithm for working with the charger: 202 202 203 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main3.3\.Configuration.3\.3 Control.WebHome||anchor="HCharge"]]).208 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11). 204 204 205 -(% class="box infomessage" %) 206 -((( 207 -After changing the settings, restart the BMS Main 3 device. 208 -))) 210 +**After changing the settings, restart the BMS Main 3 device.** 209 209 210 -=== Webasto charger === 211 211 213 +1. 214 +11. 215 +111. Webasto charger 216 + 212 212 To change the parameters of communication with a Webasto charger, select the "External equipment → Chargers → Webasto charger" section: 213 213 214 -[[image:1733330947595-790.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="107" width="800"]]219 +[[image:1733330947595-790.png]] 215 215 216 216 In this section: 217 217 ... ... @@ -226,18 +226,18 @@ 226 226 227 227 Algorithm for working with the charger: 228 228 229 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main3.3\.Configuration.3\.3 Control.WebHome||anchor="HCharge"]]).234 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11). 230 230 231 -(% class="box infomessage" %) 232 -((( 233 -After changing the settings, restart the BMS Main 3 device. 234 -))) 236 +**After changing the settings, restart the BMS Main 3 device.** 235 235 236 -=== Skytronic charger === 237 237 239 +1. 240 +11. 241 +111. Skytronic charger 242 + 238 238 To change the parameters of communication with a Skytronic charger, select the "External equipment → Chargers → Skytronic charger" section: 239 239 240 -[[image:1733330947596-629.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="106" width="800"]]245 +[[image:1733330947596-629.png]] 241 241 242 242 In this section: 243 243 ... ... @@ -250,11 +250,14 @@ 250 250 * Charge current – maximum charging current, A; 251 251 * Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established. 252 252 253 -=== CCS Fast charge controller === 254 254 259 +1. 260 +11. 261 +111. CCS Fast charge controller 262 + 255 255 To change the parameters of communication with a CCS Fast charge controller, select the "External equipment → Chargers → CCS Fast charge controller" section: 256 256 257 -[[image:1733330947597-290.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="287" width="800"]]265 +[[image:1733330947597-290.png]] 258 258 259 259 In this section: 260 260 ... ... @@ -284,11 +284,13 @@ 284 284 * Number of retries to restart nominal charge – number of retries to restart nominal charge after connection loss with charger; 285 285 * Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established. 286 286 287 -=== Sunny Island inverter === 295 +1. 296 +11. 297 +111. Sunny Island inverter 288 288 289 289 To change the communication parameters with an SMA Sunny Island inverter, select the "External equipment → Inverters and loads → SMA Sunny Island inverter" section: 290 290 291 -[[image:1733330959804-806.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="141" width="800"]]301 +[[image:1733330959804-806.png]] 292 292 293 293 In this section: 294 294 ... ... @@ -306,11 +306,14 @@ 306 306 307 307 When working with the Sunny Island inverter, the BMS Main 3 device sends messages with the values of voltage and charge/discharge current continuously with the period “Output period”: Charging voltage, Charging current, Discharging voltage, Discharging current. 308 308 309 -=== Pylontech inverter === 310 310 320 +1. 321 +11. 322 +111. Pylontech inverter 323 + 311 311 To change the parameters of communication with a Pylontech inverter, select the "External equipment → Inverters and loads → Pylontech inverter" section: 312 312 313 -[[image:1733330959806-653.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="119" width="800"]]326 +[[image:1733330959806-653.png]] 314 314 315 315 In this section: 316 316 ... ... @@ -326,11 +326,14 @@ 326 326 * Discharge voltage (min) – minimum discharging voltage, V; 327 327 * Discharge current – maximum discharging current, А. 328 328 329 -=== ASTOM load bank (cycling) === 330 330 343 +1. 344 +11. 345 +111. ASTOM load bank (cycling) 346 + 331 331 To change the parameters of communication with a ASTOM load bank, select the "External equipment → Inverters and loads → ASTOM load bank (cycling)" section: 332 332 333 -[[image:1733330959806-204.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="170" width="800"]]349 +[[image:1733330959806-204.png]] 334 334 335 335 In this section: 336 336 ... ... @@ -349,13 +349,16 @@ 349 349 * Voltage difference – difference between the minimum and maximum cell voltages for error to be generated and cycling to be stopped, V; 350 350 * Delay before setting the error – a delay before generating an error, second. 351 351 352 -=== HYG Class I-III truck === 353 353 369 +1. 370 +11. 371 +111. HYG Class I-III truck 372 + 354 354 The HYG Class I-III equipment is installed on the forklifts by the group of companies HYSTER-YALE. 355 355 356 356 To change communication parameters with HYG Class I-III equipment, select the "External equipment → Trucks and Vehicles → HYG Class I-III truck" section: 357 357 358 -[[image:1735 227832802-527.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="337" width="800"]]377 +[[image:1733330959808-973.png]] 359 359 360 360 In this section: 361 361 ... ... @@ -368,12 +368,10 @@ 368 368 ** II-III; 369 369 ** I-III Gen.2; 370 370 * Node ID – an equipment identifier in the CANopen network; 371 -* Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to the forklift; 372 -* Heartbeat period – Heartbeat sending period, millisecond; 373 373 * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “HYG offline“ flag is set), millisecond; at a value of 0 milliseconds, the "HYG offline" error does not occur; 374 374 * Inhibit charging on the "HYG offline" error – a flag to forbid charging if the "HYG offline" error is generated; 375 375 * Inhibit discharging on the "HYG offline" error – a flag to forbid discharging if the "HYG offline" error is generated; 376 -* Prevent discharging on the “Charger connected” signal and the "HYG offline" error – a flag to forbid discharging if the “Charger connected” signal presents and "HYG offline" error is generated;393 +* Inhibit discharging on the “Charger connected” signal and the "HYG offline" error – a flag to forbid discharging if the “Charger connected” signal presents and "HYG offline" error is generated; 377 377 * Maximum voltage, V; 378 378 * Minimum voltage, V; 379 379 * Maximum charge current, А; ... ... @@ -382,25 +382,22 @@ 382 382 * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %; 383 383 * Thermal derate (0%): Battery temperature - a value of the battery temperature at which the thermal derate starts, °C; 384 384 * Thermal derate (0%): Contactor temperature - a value of the contactor temperature at which the thermal derate starts, °C; 385 -* 402 +* Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to the forklift; 403 +* Heartbeat period – Heartbeat sending period, millisecond. 386 386 387 -(% class="box infomessage" %) 388 -((( 389 -**Note:** Dependence of the thermal derate from the battery and contactor temperature is linear. The system sends maximum value of the thermal derate among values calculated for the battery temperature and contactor temperature. 390 -))) 405 +Note – Dependence of the thermal derate from the battery and contactor temperature is linear. The system sends maximum value of the thermal derate among values calculated for the battery temperature and contactor temperature. 391 391 392 392 The device with the identifier “Node ID” continuously transmits control commands to the forklift the with a period of 100 milliseconds. 393 393 394 -(% class="box infomessage" %) 395 -((( 396 -After changing the settings, restart the BMS Main 3 device. 397 -))) 409 +**After changing the settings, restart the BMS Main 3 device.** 398 398 399 -=== Combilift truck === 411 +1. 412 +11. 413 +111. Combilift truck 400 400 401 401 To change communication parameters with a Combilift forklift, select the "External equipment → Trucks and Vehicles → Combilift truck" section: 402 402 403 -[[image:1733330972246-129.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="171" width="800"]]417 +[[image:1733330972246-129.png]] 404 404 405 405 In this section: 406 406 ... ... @@ -420,16 +420,16 @@ 420 420 421 421 The device with the identifier “Node ID” continuously transmits control commands to the forklift with a period of 200 milliseconds. 422 422 423 -(% class="box infomessage" %) 424 -((( 425 -After changing the settings, restart the BMS Main 3 device. 426 -))) 437 +**After changing the settings, restart the BMS Main 3 device.** 427 427 428 -=== Spirit AGV === 429 429 440 +1. 441 +11. 442 +111. Spirit AGV 443 + 430 430 To change communication parameters with a Spirit AeroSystems truck, select the "External equipment → Trucks and Vehicles → Spirit AGV" section: 431 431 432 -[[image:1733330972257-158.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="182" width="800"]]446 +[[image:1733330972257-158.png]] 433 433 434 434 In this section: 435 435 ... ... @@ -453,13 +453,16 @@ 453 453 454 454 The device with the identifier “Node ID” continuously transmits control commands to the truck with a period of 100 milliseconds. 455 455 456 -=== Crown truck === 457 457 471 +1. 472 +11. 473 +111. Crown truck 474 + 458 458 The BMS Main 3 device uses the BMS Crown adapter to control powering the Crown forklift. 459 459 460 460 To change communication parameters with the BMS Crown adapter, select the "External equipment → Trucks and Vehicles → Crown truck" section: 461 461 462 -[[image:1733330972258-463.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="96" width="800"]]479 +[[image:1733330972258-463.png]] 463 463 464 464 In this section: 465 465 ... ... @@ -519,18 +519,18 @@ 519 519 520 520 In this state, the discharging contactor is **open** and the "Crown error" is generated. If the "Inhibit discharging on the EWS signal" is not set, then after T = 10 seconds, the "Crown error" is cleared and the transition to the "Discharging Off" state is performed. 521 521 522 -The value of T is set in the "Delay before starting discharging" field (see [[Discharge>>doc:Battery management systems.BMS Main3.3\.Configuration.3\.3 Control.WebHome||anchor="HDischarge"]]).539 +The value of T is set in the "Delay before starting discharging" field (see section 2.3.12). 523 523 524 -(% class="box infomessage" %) 525 -((( 526 -After changing the settings, restart the BMS Main 3 device. 527 -))) 541 +**After changing the settings, restart the BMS Main 3 device.** 528 528 529 -=== ZiK truck === 530 530 544 +1. 545 +11. 546 +111. ZiK truck 547 + 531 531 To change communication parameters with a ZiK truck, select the "External equipment → Trucks and Vehicles → ZiK truck" section: 532 532 533 -[[image:1733330985625-186.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="800"]]550 +[[image:1733330985625-186.png]] 534 534 535 535 In this section: 536 536 ... ... @@ -544,16 +544,16 @@ 544 544 545 545 The BMS with the identifier “Node ID” continuously transmits control commands to the truck with a period of 100 milliseconds. 546 546 547 -(% class="box infomessage" %) 548 -((( 549 -After changing the settings, restart the BMS Main 3 device. 550 -))) 564 +**After changing the settings, restart the BMS Main 3 device.** 551 551 552 -=== Evocargo Evo1.1 truck === 553 553 567 +1. 568 +11. 569 +111. Evocargo Evo1.1 truck 570 + 554 554 To change communication parameters with an Evocargo Evo1.1 truck, select the "External equipment → Trucks and Vehicles → Evocargo Evo1.1 truck" section: 555 555 556 -[[image:1733330985627-145.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="87" width="800"]]573 +[[image:1733330985627-145.png]] 557 557 558 558 In this section: 559 559 ... ... @@ -560,11 +560,14 @@ 560 560 * Enable – a flag to enable communication with the truck; 561 561 * Receive timeout – a timeout for receiving packets from the truck, millisecond. 562 562 563 -=== BKM vehicle === 564 564 581 +1. 582 +11. 583 +111. BKM vehicle 584 + 565 565 To change communication parameters with a BKM vehicle, select the "External equipment → Trucks and Vehicles → BKM vehicle" section: 566 566 567 -[[image:1733330985627-310.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="90" width="800"]]587 +[[image:1733330985627-310.png]] 568 568 569 569 In this section: 570 570 ... ... @@ -575,13 +575,16 @@ 575 575 * Receive timeout – a timeout for receiving packets from the vehicle. 576 576 * Number of Logics in a pack. 577 577 578 -=== Basic J1939 vehicle === 579 579 599 +1. 600 +11. 601 +111. Basic J1939 vehicle 602 + 580 580 The basic vehicle protocol J1939 is developed by Movicom Electric, and its description is available upon request. Using this protocol, information about the parameters of the battery can be obtained. The protocol also implements the management of battery operation modes. 581 581 582 582 Communication parameters via the Basic J1939 protocol are configured in the “External equipment → Trucks and Vehicles → Basic J1939 vehicle” section: 583 583 584 -[[image:1733330996003-704.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="98" width="800"]]607 +[[image:1733330996003-704.png]] 585 585 586 586 In this section: 587 587 ... ... @@ -593,11 +593,14 @@ 593 593 * Receive vehicle messages – a flag to activate receiving vehicle messages; 594 594 * First vehicle message ID – an identifier of the first message of the vehicle in the J1939 network. 595 595 596 -=== Bender iso165C === 597 597 620 +1. 621 +11. 622 +111. Bender iso165C 623 + 598 598 To change communication parameters with a Bender iso165C, select the "External equipment → IMD → Bender iso165C" section: 599 599 600 -[[image:1733330996004-140.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="108" width="800"]]626 +[[image:1733330996004-140.png]] 601 601 602 602 In this section: 603 603 ... ... @@ -610,11 +610,14 @@ 610 610 * Threshold to detect insulation error – threshold resistance value to generate the insulation error, Ohm; 611 611 * Threshold to detect insulation warning – threshold resistance value to generate the insulation warning, Ohm. 612 612 613 -=== BMS IMD === 614 614 640 +1. 641 +11. 642 +111. BMS IMD 643 + 615 615 To change communication parameters with a BMS IMD, select the "External equipment → IMD → BMD IMD " section: 616 616 617 -[[image:1733330996005-297.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="109" width="800"]]646 +[[image:1733330996005-297.png]] 618 618 619 619 In this section: 620 620 ... ... @@ -627,13 +627,16 @@ 627 627 * Threshold to detect insulation alarm, Ohm; 628 628 * Threshold to detect insulation warning, Ohm. 629 629 630 -=== Main X === 631 631 660 +1. 661 +11. 662 +111. Main X 663 + 632 632 The BMS Main 3 device can connect to BMS Main X strings controller. 633 633 634 634 Communication parameters with the Main X are configured in the "External equipment → BMS → Main X" section: 635 635 636 -[[image:1733330996006-677.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="106" width="800"]]668 +[[image:1733330996006-677.png]] 637 637 638 638 In this section: 639 639
- 1735227832802-527.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -68.1 KB - Content