Changes for page 3.5 External equipment
Last modified by Admin on 2025/06/19 12:32
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -355,7 +355,7 @@ 355 355 356 356 To change communication parameters with HYG Class I-III equipment, select the "External equipment → Trucks and Vehicles → HYG Class I-III truck" section: 357 357 358 -[[image:1735 227832802-527.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="337" width="800"]]358 +[[image:1733330959808-973.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="234" width="800"]] 359 359 360 360 In this section: 361 361 ... ... @@ -368,12 +368,10 @@ 368 368 ** II-III; 369 369 ** I-III Gen.2; 370 370 * Node ID – an equipment identifier in the CANopen network; 371 -* Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to the forklift; 372 -* Heartbeat period – Heartbeat sending period, millisecond; 373 373 * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “HYG offline“ flag is set), millisecond; at a value of 0 milliseconds, the "HYG offline" error does not occur; 374 374 * Inhibit charging on the "HYG offline" error – a flag to forbid charging if the "HYG offline" error is generated; 375 375 * Inhibit discharging on the "HYG offline" error – a flag to forbid discharging if the "HYG offline" error is generated; 376 -* Prevendischarging on the “Charger connected” signal and the "HYG offline" error – a flag to forbid discharging if the “Charger connected” signal presents and "HYG offline" error is generated;374 +* Inhibit discharging on the “Charger connected” signal and the "HYG offline" error – a flag to forbid discharging if the “Charger connected” signal presents and "HYG offline" error is generated; 377 377 * Maximum voltage, V; 378 378 * Minimum voltage, V; 379 379 * Maximum charge current, А; ... ... @@ -382,7 +382,8 @@ 382 382 * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %; 383 383 * Thermal derate (0%): Battery temperature - a value of the battery temperature at which the thermal derate starts, °C; 384 384 * Thermal derate (0%): Contactor temperature - a value of the contactor temperature at which the thermal derate starts, °C; 385 -* 383 +* Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to the forklift; 384 +* Heartbeat period – Heartbeat sending period, millisecond. 386 386 387 387 (% class="box infomessage" %) 388 388 (((