Changes for page 3.5 External equipment

Last modified by Admin on 2025/06/19 12:32

From version 9.1
edited by Admin
on 2024/12/26 15:43
Change comment: Uploaded new attachment "1735227832802-527.png", version {1}
To version 9.3
edited by Admin
on 2024/12/26 15:45
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -355,7 +355,7 @@
355 355  
356 356  To change communication parameters with HYG Class I-III equipment, select the "External equipment → Trucks and Vehicles → HYG Class I-III truck" section:
357 357  
358 -[[image:1733330959808-973.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="234" width="800"]]
358 +[[image:1735227832802-527.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="337" width="800"]]
359 359  
360 360  In this section:
361 361  
... ... @@ -368,10 +368,12 @@
368 368  ** II-III;
369 369  ** I-III Gen.2;
370 370  * Node ID – an equipment identifier in the CANopen network;
371 +* Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to the forklift;
372 +* Heartbeat period – Heartbeat sending period, millisecond;
371 371  * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “HYG offline“ flag is set), millisecond; at a value of 0 milliseconds, the "HYG offline" error does not occur;
372 372  * Inhibit charging on the "HYG offline" error – a flag to forbid charging if the "HYG offline" error is generated;
373 373  * Inhibit discharging on the "HYG offline" error – a flag to forbid discharging if the "HYG offline" error is generated;
374 -* Inhibit discharging on the “Charger connected” signal and the "HYG offline" error – a flag to forbid discharging if the “Charger connected” signal presents and "HYG offline" error is generated;
376 +* Prevent discharging on the “Charger connected” signal and the "HYG offline" error – a flag to forbid discharging if the “Charger connected” signal presents and "HYG offline" error is generated;
375 375  * Maximum voltage, V;
376 376  * Minimum voltage, V;
377 377  * Maximum charge current, А;
... ... @@ -380,8 +380,7 @@
380 380  * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %;
381 381  * Thermal derate (0%): Battery temperature - a value of the battery temperature at which the thermal derate starts, °C;
382 382  * Thermal derate (0%): Contactor temperature - a value of the contactor temperature at which the thermal derate starts, °C;
383 -* Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to the forklift;
384 -* Heartbeat period – Heartbeat sending period, millisecond.
385 +*
385 385  
386 386  (% class="box infomessage" %)
387 387  (((