Changes for page 3.5 External equipment
Last modified by Admin on 2025/06/19 12:32
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -355,7 +355,7 @@ 355 355 356 356 To change communication parameters with HYG Class I-III equipment, select the "External equipment → Trucks and Vehicles → HYG Class I-III truck" section: 357 357 358 -[[image:173 3330959808-973.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="234" width="800"]]358 +[[image:1735227832802-527.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="337" width="800"]] 359 359 360 360 In this section: 361 361 ... ... @@ -368,20 +368,21 @@ 368 368 ** II-III; 369 369 ** I-III Gen.2; 370 370 * Node ID – an equipment identifier in the CANopen network; 371 +* Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to the forklift; 372 +* Heartbeat period – Heartbeat sending period, millisecond; 371 371 * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “HYG offline“ flag is set), millisecond; at a value of 0 milliseconds, the "HYG offline" error does not occur; 372 -* Inhibit charging on the "HYG offline" error – a flag to forbid charging if the "HYG offline" error is generated; 373 -* Inhibit discharging on the "HYG offline" error – a flag to forbid discharging if the "HYG offline" error is generated; 374 -* Inhibit discharging on the “Charger connected” signal and the "HYG offline" error – a flag to forbid discharging if the “Charger connected” signal presents and "HYG offline" error is generated; 374 +* Prevent discharging on the “Charger connected” signal and the "HYG offline" error – a flag to forbid discharging if the “Charger connected” signal presents and "HYG offline" error is generated; 375 375 * Maximum voltage, V; 376 376 * Minimum voltage, V; 377 377 * Maximum charge current, А; 378 378 * Maximum discharge current, А; 379 -* SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %; 380 380 * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %; 381 -* Thermal derate (0%):Batterytemperature-avalueof thebatterytemperature atwhich thethermalderatestarts,°C;380 +* SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %; 382 382 * Thermal derate (0%): Contactor temperature - a value of the contactor temperature at which the thermal derate starts, °C; 383 -* Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to the forklift; 384 -* Heartbeat period – Heartbeat sending period, millisecond. 382 +* Thermal derate (0%): High battery temperature - a value of the high battery temperature at which the thermal derate starts, °C; 383 +* Thermal derate (0%): Low battery temperature - a value of the low battery temperature at which the thermal derate starts, °C; 384 +* Nominal battery voltage, V; 385 +* Warran 385 385 386 386 (% class="box infomessage" %) 387 387 (((
- 1735227832802-527.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +68.1 KB - Content