Changes for page 3.5 External equipment

Last modified by Admin on 2025/06/19 12:32

From version 5.2
edited by Admin
on 2024/12/09 17:26
Change comment: Update document after refactoring.
To version 6.1
edited by Admin
on 2024/12/11 11:59
Change comment: There is no comment for this version

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -drafts.BMS Main 3.3\. Settings.WebHome
1 +Battery management systems.BMS Main 3.3\. Settings.WebHome
Content
... ... @@ -41,7 +41,7 @@
41 41  
42 42  Algorithm for working with the charger:
43 43  
44 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11).
44 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Settings.3\.3 Control.WebHome||anchor="HCharge"]]).
45 45  
46 46  === Eltek charger ===
47 47  
... ... @@ -64,7 +64,7 @@
64 64  
65 65  Algorithm for working with the charger:
66 66  
67 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11).
67 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Settings.3\.3 Control.WebHome||anchor="HCharge"]]).
68 68  
69 69  === MicroPower charger ===
70 70  
... ... @@ -89,11 +89,11 @@
89 89  
90 90  Algorithm for working with the charger:
91 91  
92 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11).
92 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Settings.3\.3 Control.WebHome||anchor="HCharge"]]).
93 93  
94 94  (% class="box warningmessage" %)
95 95  (((
96 -**Warning! **To work properly with the charger, it is necessary to turn on sending synchronization messages over the CANopen network (see section 2.5.2).
96 +**Warning! **To work properly with the charger, it is necessary to turn on sending synchronization messages over the CANopen network (see [[CAN1>>doc:Battery management systems.BMS Main 3.3\. Settings.3\.6 Connectivity.WebHome||anchor="HCAN1"]]).
97 97  )))
98 98  
99 99  (% class="box infomessage" %)
... ... @@ -121,7 +121,7 @@
121 121  
122 122  Algorithm for working with the charger:
123 123  
124 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11).
124 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Settings.3\.3 Control.WebHome||anchor="HCharge"]]).
125 125  
126 126  === Bassi charger ===
127 127  
... ... @@ -144,7 +144,7 @@
144 144  
145 145  Algorithm for working with the charger:
146 146  
147 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11).
147 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Settings.3\.3 Control.WebHome||anchor="HCharge"]]).
148 148  
149 149  (% class="box infomessage" %)
150 150  (((
... ... @@ -171,7 +171,7 @@
171 171  
172 172  Algorithm for working with the charger:
173 173  
174 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11).
174 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Settings.3\.3 Control.WebHome||anchor="HCharge"]]).
175 175  
176 176  (% class="box infomessage" %)
177 177  (((
... ... @@ -200,7 +200,7 @@
200 200  
201 201  Algorithm for working with the charger:
202 202  
203 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11).
203 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Settings.3\.3 Control.WebHome||anchor="HCharge"]]).
204 204  
205 205  (% class="box infomessage" %)
206 206  (((
... ... @@ -226,7 +226,7 @@
226 226  
227 227  Algorithm for working with the charger:
228 228  
229 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11).
229 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Settings.3\.3 Control.WebHome||anchor="HCharge"]]).
230 230  
231 231  (% class="box infomessage" %)
232 232  (((
... ... @@ -518,7 +518,7 @@
518 518  
519 519  In this state, the discharging contactor is **open** and the "Crown error" is generated. If the "Inhibit discharging on the EWS signal" is not set, then after T = 10 seconds, the "Crown error" is cleared and the transition to the "Discharging Off" state is performed.
520 520  
521 -The value of T is set in the "Delay before starting discharging" field (see section 2.3.12).
521 +The value of T is set in the "Delay before starting discharging" field (see [[Discharge>>doc:Battery management systems.BMS Main 3.3\. Settings.3\.3 Control.WebHome||anchor="HDischarge"]]).
522 522  
523 523  (% class="box infomessage" %)
524 524  (((