... ... @@ -373,7 +373,7 @@
373 373  * Heartbeat period – Heartbeat sending period, millisecond;
374 374  * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “HYG offline“ flag is set), millisecond; at a value of 0 milliseconds, the "HYG offline" error does not occur;
375 375  * Prevent discharging on the “Charger connected” signal and the "HYG offline" error – a flag to forbid discharging if the “Charger connected” signal presents and "HYG offline" error is generated;
376 -* Do not set the 'HYG offline' error if the 'Charger connected' is present – flag to prevent the "HYG offline" error from occurring if the "Charger connected" signal is set;
376 +* Do not set the 'HYG offline' error if the 'Charger connected' is present – flag to prevent the "HYG offline" error from occurring if the "Charger connected" signal is set (see the "External equipment - Trucks and Vehicles - HYG Class I-III truck" section);
377 377  * Wait for the confirmation from the truck before closing the charging contactor – flag that controls whether to wait for confirmation from the HYG truck or not, to allow the battery to be charged;
378 378  * Maximum voltage, V;
379 379  * Minimum voltage, V;
... ... @@ -426,8 +426,9 @@
426 426  * Node ID – a BMS identifier in the CANopen network;
427 427  * Truck ID – a forklift identifier in the CANopen network;
428 428  * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “Combilift offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Combilift offline" error does not occur;
429 -* Do not set the "Combilift offline" error on the "Charger connected" signal – flag to prevent the "Combilift offline" error from occurring if the "Charger connected" signal is set;
430 -* Wait for the confirmation from the truck before closing the charging contactor – flag that controls whether to wait for confirmation from the HYG truck or not, to allow the battery to be charged;
429 +* Inhibit charging on the "Combilift offline" error – a flag to forbid charging if the "Combilift offline" error is generated;
430 +* Inhibit discharging on "Combilift offline" error – a flag to forbid discharging if the "Combilift offline" error is generated;
431 +* Do not set the "Combilift offline" error on the "Charger connected" signal;
431 431  * SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %;
432 432  * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %;
433 433  * Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to forklift;