Changes for page 3.5 External equipment
Last modified by Admin on 2025/06/19 12:32
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -428,8 +428,7 @@ 428 428 * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “Combilift offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Combilift offline" error does not occur; 429 429 * Inhibit charging on the "Combilift offline" error – a flag to forbid charging if the "Combilift offline" error is generated; 430 430 * Inhibit discharging on "Combilift offline" error – a flag to forbid discharging if the "Combilift offline" error is generated; 431 -* Do not set the "Combilift offline" error on the "Charger connected" signal – flag to prevent the "Combilift offline" error from occurring if the "Charger connected" signal is set; 432 -* Wait for the confirmation from the truck before closing the charging contactor – flag that controls whether to wait for confirmation from the HYG truck or not, to allow the battery to be charged; 431 +* Do not set the "Combilift offline" error on the "Charger connected" signal; 433 433 * SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %; 434 434 * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %; 435 435 * Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to forklift;