Changes for page 3.5 External equipment

Last modified by Admin on 2025/06/19 12:32

From version 23.1
edited by Admin
on 2025/06/19 12:28
Change comment: There is no comment for this version
To version 12.2
edited by Admin
on 2024/12/26 15:50
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,5 +1,5 @@
1 1  (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 -= Configuration =
2 += Settings =
3 3  
4 4  (% data-numbered-headings-start="5" style="--numbered-headings-start: 4;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
5 5  == External equipment ==
... ... @@ -93,7 +93,7 @@
93 93  
94 94  (% class="box warningmessage" %)
95 95  (((
96 -**Warning! **To work properly with the charger, it is necessary to turn on sending synchronization messages over the CANopen network (see [[CAN2 (int)>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.6 Connectivity.WebHome||anchor="HCAN2int"]]).
96 +**Warning! **To work properly with the charger, it is necessary to turn on sending synchronization messages over the CANopen network (see [[CAN1>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.6 Connectivity.WebHome||anchor="HCAN1"]]).
97 97  )))
98 98  
99 99  (% class="box infomessage" %)
... ... @@ -140,7 +140,6 @@
140 140  * Receive timeout – a timeout for receiving packets from the charger (if there is no data being received from the charger for a given time, the connection loss flag is set), millisecond;
141 141  * Charge voltage – maximum charging voltage, V;
142 142  * Charge current – maximum charging current, A;
143 -* Current rize time, second;
144 144  * Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established.
145 145  
146 146  Algorithm for working with the charger:
... ... @@ -285,7 +285,7 @@
285 285  * Number of retries to restart nominal charge – number of retries to restart nominal charge after connection loss with charger;
286 286  * Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established.
287 287  
288 -=== SMA Sunny Island inverter ===
287 +=== Sunny Island inverter ===
289 289  
290 290  To change the communication parameters with an SMA Sunny Island inverter, select the "External equipment → Inverters and loads → SMA Sunny Island inverter" section:
291 291  
... ... @@ -356,7 +356,7 @@
356 356  
357 357  To change communication parameters with HYG Class I-III equipment, select the "External equipment → Trucks and Vehicles → HYG Class I-III truck" section:
358 358  
359 -[[image:1750335865762-266.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="369" width="800"]]
358 +[[image:1735227832802-527.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="337" width="800"]]
360 360  
361 361  In this section:
362 362  
... ... @@ -373,8 +373,6 @@
373 373  * Heartbeat period – Heartbeat sending period, millisecond;
374 374  * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “HYG offline“ flag is set), millisecond; at a value of 0 milliseconds, the "HYG offline" error does not occur;
375 375  * Prevent discharging on the “Charger connected” signal and the "HYG offline" error – a flag to forbid discharging if the “Charger connected” signal presents and "HYG offline" error is generated;
376 -* Do not set the 'HYG offline' error if the 'Charger connected' is present – flag to prevent the "HYG offline" error from occurring if the "Charger connected" signal is set (see the "External equipment - Trucks and Vehicles - HYG Class I-III truck" section);
377 -* Wait for the confirmation from the truck before closing the charging contactor – flag that controls whether to wait for confirmation from the HYG truck or not, to allow the battery to be charged;
378 378  * Maximum voltage, V;
379 379  * Minimum voltage, V;
380 380  * Maximum charge current, А;
... ... @@ -397,8 +397,6 @@
397 397  * Battery ID;
398 398  * Battery serial number.
399 399  
400 -TBA
401 -
402 402  (% class="box infomessage" %)
403 403  (((
404 404  **Note:** Dependence of the thermal derate from the battery and contactor temperature is linear. The system sends maximum value of the thermal derate among values calculated for the battery temperature and contactor temperature.
... ... @@ -415,7 +415,7 @@
415 415  
416 416  To change communication parameters with a Combilift forklift, select the "External equipment → Trucks and Vehicles → Combilift truck" section:
417 417  
418 -[[image:1750336011634-554.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="159" width="800"]]
413 +[[image:1733330972246-129.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="171" width="800"]]
419 419  
420 420  In this section:
421 421  
... ... @@ -428,8 +428,6 @@
428 428  * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “Combilift offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Combilift offline" error does not occur;
429 429  * Inhibit charging on the "Combilift offline" error – a flag to forbid charging if the "Combilift offline" error is generated;
430 430  * Inhibit discharging on "Combilift offline" error – a flag to forbid discharging if the "Combilift offline" error is generated;
431 -* Do not set the "Combilift offline" error on the "Charger connected" signal – flag to prevent the "Combilift offline" error from occurring if the "Charger connected" signal is set;
432 -* Wait for the confirmation from the truck before closing the charging contactor – flag that controls whether to wait for confirmation from the HYG truck or not, to allow the battery to be charged;
433 433  * SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %;
434 434  * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %;
435 435  * Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to forklift;
... ... @@ -648,11 +648,9 @@
648 648  
649 649  Communication parameters with the Main X are configured in the "External equipment → BMS → Main X" section:
650 650  
651 -[[image:1735228238119-343.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="82" width="800"]]
644 +[[image:1735228238119-343.png]]
652 652  
653 653  In this section:
654 654  
655 655  * Enable – a flag to enable communication with the BMS Main X;
656 -* Receive timeout – a timeout for receiving packets from the BMS Main X (if no data is being received from the BMS Main X during this time, the “Inhibit charging“ and “Inhibit discharging” signals may be generated), millisecond;
657 -* Set the 'Inhibit charging' signal if BMS Main X is offline;
658 -* Set the 'Inhibit discharging' signal if BMS Main X is offline;
649 +* Receive timeout – a timeout for receiving packets from the BMS Main X (if no data is being received from the BMS Main X during this time, the “Inhibit charging“ and “Inhibit discharging” signals may be generated), millisecond.
1750335865762-266.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -73.6 KB
Content
1750336011634-554.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -31.1 KB
Content