... ... @@ -426,7 +426,6 @@ 426 426 * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “Combilift offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Combilift offline" error does not occur; 427 427 * Inhibit charging on the "Combilift offline" error – a flag to forbid charging if the "Combilift offline" error is generated; 428 428 * Inhibit discharging on "Combilift offline" error – a flag to forbid discharging if the "Combilift offline" error is generated; 429 -* Do not set the "Combilift offline" error on the "Charger connected" signal; 430 430 * SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %; 431 431 * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %; 432 432 * Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to forklift;