Changes for page 3.5 External equipment
Last modified by Admin on 2025/06/19 12:32
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Configuration =2 += Settings = 3 3 4 4 (% data-numbered-headings-start="5" style="--numbered-headings-start: 4;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 5 == External equipment == ... ... @@ -93,7 +93,7 @@ 93 93 94 94 (% class="box warningmessage" %) 95 95 ((( 96 -**Warning! **To work properly with the charger, it is necessary to turn on sending synchronization messages over the CANopen network (see [[CAN 2 (int)>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.6 Connectivity.WebHome||anchor="HCAN2int"]]).96 +**Warning! **To work properly with the charger, it is necessary to turn on sending synchronization messages over the CANopen network (see [[CAN1>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.6 Connectivity.WebHome||anchor="HCAN1"]]). 97 97 ))) 98 98 99 99 (% class="box infomessage" %) ... ... @@ -140,7 +140,6 @@ 140 140 * Receive timeout – a timeout for receiving packets from the charger (if there is no data being received from the charger for a given time, the connection loss flag is set), millisecond; 141 141 * Charge voltage – maximum charging voltage, V; 142 142 * Charge current – maximum charging current, A; 143 -* Current rize time, second; 144 144 * Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established. 145 145 146 146 Algorithm for working with the charger: ... ... @@ -285,7 +285,7 @@ 285 285 * Number of retries to restart nominal charge – number of retries to restart nominal charge after connection loss with charger; 286 286 * Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established. 287 287 288 -=== S MA Sunny Island inverter ===287 +=== Sunny Island inverter === 289 289 290 290 To change the communication parameters with an SMA Sunny Island inverter, select the "External equipment → Inverters and loads → SMA Sunny Island inverter" section: 291 291 ... ... @@ -395,8 +395,6 @@ 395 395 * Battery ID; 396 396 * Battery serial number. 397 397 398 -TBA 399 - 400 400 (% class="box infomessage" %) 401 401 ((( 402 402 **Note:** Dependence of the thermal derate from the battery and contactor temperature is linear. The system sends maximum value of the thermal derate among values calculated for the battery temperature and contactor temperature. ... ... @@ -426,7 +426,6 @@ 426 426 * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “Combilift offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Combilift offline" error does not occur; 427 427 * Inhibit charging on the "Combilift offline" error – a flag to forbid charging if the "Combilift offline" error is generated; 428 428 * Inhibit discharging on "Combilift offline" error – a flag to forbid discharging if the "Combilift offline" error is generated; 429 -* Do not set the "Combilift offline" error on the "Charger connected" signal; 430 430 * SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %; 431 431 * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %; 432 432 * Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to forklift;