Changes for page 3.5 External equipment

Last modified by Admin on 2025/06/19 12:32

From version 2.1
edited by Admin
on 2024/12/04 16:59
Change comment: There is no comment for this version
To version 9.2
edited by Admin
on 2024/12/26 15:45
Change comment: There is no comment for this version

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -drafts.bms-main-3.3\. Settings.WebHome
1 +Battery management systems.BMS Main 3.3\. Configuration.WebHome
Content
... ... @@ -1,10 +1,10 @@
1 1  (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 2  = Settings =
3 3  
4 -(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
4 +(% data-numbered-headings-start="5" style="--numbered-headings-start: 4;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
5 5  == External equipment ==
6 6  
7 -The BMS Main 3 device supports joint operation with chargers, inverters, indication panels, trucks and vehicle controllers.
7 +The BMS Main 3 device supports joint operation with chargers, inverters, indication panels, trucks and vehicle controllers.
8 8  
9 9  === J1939 charger ===
10 10  
... ... @@ -41,7 +41,7 @@
41 41  
42 42  Algorithm for working with the charger:
43 43  
44 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11).
44 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]]).
45 45  
46 46  === Eltek charger ===
47 47  
... ... @@ -64,7 +64,7 @@
64 64  
65 65  Algorithm for working with the charger:
66 66  
67 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11).
67 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]]).
68 68  
69 69  === MicroPower charger ===
70 70  
... ... @@ -89,11 +89,11 @@
89 89  
90 90  Algorithm for working with the charger:
91 91  
92 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11).
92 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]]).
93 93  
94 94  (% class="box warningmessage" %)
95 95  (((
96 -**Warning! **To work properly with the charger, it is necessary to turn on sending synchronization messages over the CANopen network (see section 2.5.2).
96 +**Warning! **To work properly with the charger, it is necessary to turn on sending synchronization messages over the CANopen network (see [[CAN1>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.6 Connectivity.WebHome||anchor="HCAN1"]]).
97 97  )))
98 98  
99 99  (% class="box infomessage" %)
... ... @@ -121,7 +121,7 @@
121 121  
122 122  Algorithm for working with the charger:
123 123  
124 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11).
124 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]]).
125 125  
126 126  === Bassi charger ===
127 127  
... ... @@ -144,7 +144,7 @@
144 144  
145 145  Algorithm for working with the charger:
146 146  
147 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11).
147 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]]).
148 148  
149 149  (% class="box infomessage" %)
150 150  (((
... ... @@ -171,7 +171,7 @@
171 171  
172 172  Algorithm for working with the charger:
173 173  
174 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11).
174 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]]).
175 175  
176 176  (% class="box infomessage" %)
177 177  (((
... ... @@ -200,7 +200,7 @@
200 200  
201 201  Algorithm for working with the charger:
202 202  
203 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11).
203 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]]).
204 204  
205 205  (% class="box infomessage" %)
206 206  (((
... ... @@ -226,7 +226,7 @@
226 226  
227 227  Algorithm for working with the charger:
228 228  
229 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11).
229 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]]).
230 230  
231 231  (% class="box infomessage" %)
232 232  (((
... ... @@ -355,7 +355,7 @@
355 355  
356 356  To change communication parameters with HYG Class I-III equipment, select the "External equipment → Trucks and Vehicles → HYG Class I-III truck" section:
357 357  
358 -[[image:1733330959808-973.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="234" width="800"]]
358 +[[image:1735227832802-527.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="337" width="800"]]
359 359  
360 360  In this section:
361 361  
... ... @@ -368,10 +368,12 @@
368 368  ** II-III;
369 369  ** I-III Gen.2;
370 370  * Node ID – an equipment identifier in the CANopen network;
371 +* Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to the forklift;
372 +* Heartbeat period – Heartbeat sending period, millisecond;
371 371  * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “HYG offline“ flag is set), millisecond; at a value of 0 milliseconds, the "HYG offline" error does not occur;
372 372  * Inhibit charging on the "HYG offline" error – a flag to forbid charging if the "HYG offline" error is generated;
373 373  * Inhibit discharging on the "HYG offline" error – a flag to forbid discharging if the "HYG offline" error is generated;
374 -* Inhibit discharging on the “Charger connected” signal and the "HYG offline" error – a flag to forbid discharging if the “Charger connected” signal presents and "HYG offline" error is generated;
376 +* Prevendischarging on the “Charger connected” signal and the "HYG offline" error – a flag to forbid discharging if the “Charger connected” signal presents and "HYG offline" error is generated;
375 375  * Maximum voltage, V;
376 376  * Minimum voltage, V;
377 377  * Maximum charge current, А;
... ... @@ -380,8 +380,7 @@
380 380  * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %;
381 381  * Thermal derate (0%): Battery temperature - a value of the battery temperature at which the thermal derate starts, °C;
382 382  * Thermal derate (0%): Contactor temperature - a value of the contactor temperature at which the thermal derate starts, °C;
383 -* Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to the forklift;
384 -* Heartbeat period – Heartbeat sending period, millisecond.
385 +*
385 385  
386 386  (% class="box infomessage" %)
387 387  (((
... ... @@ -518,7 +518,7 @@
518 518  
519 519  In this state, the discharging contactor is **open** and the "Crown error" is generated. If the "Inhibit discharging on the EWS signal" is not set, then after T = 10 seconds, the "Crown error" is cleared and the transition to the "Discharging Off" state is performed.
520 520  
521 -The value of T is set in the "Delay before starting discharging" field (see section 2.3.12).
522 +The value of T is set in the "Delay before starting discharging" field (see [[Discharge>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HDischarge"]]).
522 522  
523 523  (% class="box infomessage" %)
524 524  (((
1735227832802-527.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +68.1 KB
Content