Changes for page 3.5 External equipment
Last modified by Admin on 2025/06/19 12:32
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Configuration =2 += Settings = 3 3 4 4 (% data-numbered-headings-start="5" style="--numbered-headings-start: 4;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 5 == External equipment == ... ... @@ -93,7 +93,7 @@ 93 93 94 94 (% class="box warningmessage" %) 95 95 ((( 96 -**Warning! **To work properly with the charger, it is necessary to turn on sending synchronization messages over the CANopen network (see [[CAN 2 (int)>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.6 Connectivity.WebHome||anchor="HCAN2int"]]).96 +**Warning! **To work properly with the charger, it is necessary to turn on sending synchronization messages over the CANopen network (see [[CAN1>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.6 Connectivity.WebHome||anchor="HCAN1"]]). 97 97 ))) 98 98 99 99 (% class="box infomessage" %) ... ... @@ -140,7 +140,6 @@ 140 140 * Receive timeout – a timeout for receiving packets from the charger (if there is no data being received from the charger for a given time, the connection loss flag is set), millisecond; 141 141 * Charge voltage – maximum charging voltage, V; 142 142 * Charge current – maximum charging current, A; 143 -* Current rize time, second; 144 144 * Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established. 145 145 146 146 Algorithm for working with the charger: ... ... @@ -285,7 +285,7 @@ 285 285 * Number of retries to restart nominal charge – number of retries to restart nominal charge after connection loss with charger; 286 286 * Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established. 287 287 288 -=== S MA Sunny Island inverter ===287 +=== Sunny Island inverter === 289 289 290 290 To change the communication parameters with an SMA Sunny Island inverter, select the "External equipment → Inverters and loads → SMA Sunny Island inverter" section: 291 291 ... ... @@ -383,20 +383,8 @@ 383 383 * Thermal derate (0%): High battery temperature - a value of the high battery temperature at which the thermal derate starts, °C; 384 384 * Thermal derate (0%): Low battery temperature - a value of the low battery temperature at which the thermal derate starts, °C; 385 385 * Nominal battery voltage, V; 386 -* Warranty SOH, %; 387 -* Warranty cycles; 388 -* Warranty hours; 389 -* Warranty usable energy, Wh; 390 -* Total energy + (initial value), Wh; 391 -* Total energy - (initial value), Wh; 392 -* Total energy regen (initial value), Wh; 393 -* Hours in service; 394 -* Battery brand; 395 -* Battery ID; 396 -* Battery serial number. 385 +* Warranty 397 397 398 -TBA 399 - 400 400 (% class="box infomessage" %) 401 401 ((( 402 402 **Note:** Dependence of the thermal derate from the battery and contactor temperature is linear. The system sends maximum value of the thermal derate among values calculated for the battery temperature and contactor temperature. ... ... @@ -426,7 +426,6 @@ 426 426 * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “Combilift offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Combilift offline" error does not occur; 427 427 * Inhibit charging on the "Combilift offline" error – a flag to forbid charging if the "Combilift offline" error is generated; 428 428 * Inhibit discharging on "Combilift offline" error – a flag to forbid discharging if the "Combilift offline" error is generated; 429 -* Do not set the "Combilift offline" error on the "Charger connected" signal; 430 430 * SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %; 431 431 * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %; 432 432 * Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to forklift; ... ... @@ -443,7 +443,7 @@ 443 443 444 444 To change communication parameters with a Spirit AeroSystems truck, select the "External equipment → Trucks and Vehicles → Spirit AGV" section: 445 445 446 -[[image:173 5228139582-964.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="800"]]432 +[[image:1733330972257-158.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="182" width="800"]] 447 447 448 448 In this section: 449 449 ... ... @@ -456,6 +456,8 @@ 456 456 ** V2; 457 457 * Node ID – a BMS identifier in the CANopen network; 458 458 * Receive timeout – a timeout for receiving packets from the truck (if no data is being received from the truck during this time, the “Spirit offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Spirit offline" error does not occur; 445 +* Inhibit charging on the "Spirit offline" error – a flag to forbid charging if the "Spirit offline" error is generated; 446 +* Inhibit discharging on the "Spirit offline" error – a flag to forbid discharging if the "Spirit offline" error is generated; 459 459 * SOC: Limited operation – a SOC level, at which the truck goes into a state of limited functionality, %; 460 460 * SOC: Lift lockout – a SOC level, at which the truck locks the lift, %; 461 461 * Send Heartbeat messages– a flag to enable generation of the Heartbeat messages to the truck; ... ... @@ -471,7 +471,7 @@ 471 471 472 472 To change communication parameters with the BMS Crown adapter, select the "External equipment → Trucks and Vehicles → Crown truck" section: 473 473 474 -[[image:173 5228176135-223.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="92" width="800"]]462 +[[image:1733330972258-463.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="96" width="800"]] 475 475 476 476 In this section: 477 477 ... ... @@ -481,7 +481,7 @@ 481 481 ** CAN2 (int); 482 482 * Node ID – a BMS Crown identifier in the CANopen network; 483 483 * Delta voltage (tolerance) – a maximum deviation between the battery voltage and the voltage output by the Crown forklift system, V; 484 -* Prevent discharging on the EWS signal – a flag to inhibit reclosing the discharging contactor after sending EWS signal to the forklift.472 +* Inhibit discharging on the EWS signal – a flag to inhibit reclosing the discharging contactor after sending EWS signal to the forklift. 485 485 486 486 When working with the Crown forklift, the algorithm for controlling the discharging contactor is changed. The state machine used to switch the discharging contactor is described below. 487 487 ... ... @@ -645,11 +645,9 @@ 645 645 646 646 Communication parameters with the Main X are configured in the "External equipment → BMS → Main X" section: 647 647 648 -[[image:173 5228238119-343.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="82" width="800"]]636 +[[image:1733330996006-677.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="106" width="800"]] 649 649 650 650 In this section: 651 651 652 652 * Enable – a flag to enable communication with the BMS Main X; 653 -* Receive timeout – a timeout for receiving packets from the BMS Main X (if no data is being received from the BMS Main X during this time, the “Inhibit charging“ and “Inhibit discharging” signals may be generated), millisecond; 654 -* Set the 'Inhibit charging' signal if BMS Main X is offline; 655 -* Set the 'Inhibit discharging' signal if BMS Main X is offline; 641 +* Receive timeout – a timeout for receiving packets from the BMS Main X (if no data is being received from the BMS Main X during this time, the “Inhibit charging“ and “Inhibit discharging” signals may be generated), millisecond.
- 1735228139582-964.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -29.3 KB - Content
- 1735228176135-223.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -18.0 KB - Content
- 1735228238119-343.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -17.6 KB - Content