Changes for page 3.5 External equipment
Last modified by Admin on 2025/06/19 12:32
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -285,7 +285,7 @@ 285 285 * Number of retries to restart nominal charge – number of retries to restart nominal charge after connection loss with charger; 286 286 * Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established. 287 287 288 -=== S MA Sunny Island inverter ===288 +=== Sunny Island inverter === 289 289 290 290 To change the communication parameters with an SMA Sunny Island inverter, select the "External equipment → Inverters and loads → SMA Sunny Island inverter" section: 291 291 ... ... @@ -426,7 +426,6 @@ 426 426 * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “Combilift offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Combilift offline" error does not occur; 427 427 * Inhibit charging on the "Combilift offline" error – a flag to forbid charging if the "Combilift offline" error is generated; 428 428 * Inhibit discharging on "Combilift offline" error – a flag to forbid discharging if the "Combilift offline" error is generated; 429 -* Do not set the "Combilift offline" error on the "Charger connected" signal; 430 430 * SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %; 431 431 * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %; 432 432 * Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to forklift;