... ... @@ -1,5 +1,5 @@
1 1  (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 -= Configuration =
2 += Settings =
3 3  
4 4  (% data-numbered-headings-start="5" style="--numbered-headings-start: 4;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
5 5  == External equipment ==
... ... @@ -93,7 +93,7 @@
93 93  
94 94  (% class="box warningmessage" %)
95 95  (((
96 -**Warning! **To work properly with the charger, it is necessary to turn on sending synchronization messages over the CANopen network (see [[CAN2 (int)>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.6 Connectivity.WebHome||anchor="HCAN2int"]]).
96 +**Warning! **To work properly with the charger, it is necessary to turn on sending synchronization messages over the CANopen network (see [[CAN1>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.6 Connectivity.WebHome||anchor="HCAN1"]]).
97 97  )))
98 98  
99 99  (% class="box infomessage" %)
... ... @@ -140,7 +140,6 @@
140 140  * Receive timeout – a timeout for receiving packets from the charger (if there is no data being received from the charger for a given time, the connection loss flag is set), millisecond;
141 141  * Charge voltage – maximum charging voltage, V;
142 142  * Charge current – maximum charging current, A;
143 -* Current rize time, second;
144 144  * Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established.
145 145  
146 146  Algorithm for working with the charger:
... ... @@ -285,7 +285,7 @@
285 285  * Number of retries to restart nominal charge – number of retries to restart nominal charge after connection loss with charger;
286 286  * Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established.
287 287  
288 -=== SMA Sunny Island inverter ===
287 +=== Sunny Island inverter ===
289 289  
290 290  To change the communication parameters with an SMA Sunny Island inverter, select the "External equipment → Inverters and loads → SMA Sunny Island inverter" section:
291 291  
... ... @@ -426,7 +426,6 @@
426 426  * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “Combilift offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Combilift offline" error does not occur;
427 427  * Inhibit charging on the "Combilift offline" error – a flag to forbid charging if the "Combilift offline" error is generated;
428 428  * Inhibit discharging on "Combilift offline" error – a flag to forbid discharging if the "Combilift offline" error is generated;
429 -* Do not set the "Combilift offline" error on the "Charger connected" signal;
430 430  * SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %;
431 431  * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %;
432 432  * Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to forklift;