Changes for page 3.5 External equipment
Last modified by Admin on 2025/06/19 12:32
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Configuration =2 += Settings = 3 3 4 4 (% data-numbered-headings-start="5" style="--numbered-headings-start: 4;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 5 == External equipment == ... ... @@ -93,7 +93,7 @@ 93 93 94 94 (% class="box warningmessage" %) 95 95 ((( 96 -**Warning! **To work properly with the charger, it is necessary to turn on sending synchronization messages over the CANopen network (see [[CAN 2 (int)>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.6 Connectivity.WebHome||anchor="HCAN2int"]]).96 +**Warning! **To work properly with the charger, it is necessary to turn on sending synchronization messages over the CANopen network (see [[CAN1>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.6 Connectivity.WebHome||anchor="HCAN1"]]). 97 97 ))) 98 98 99 99 (% class="box infomessage" %) ... ... @@ -140,7 +140,6 @@ 140 140 * Receive timeout – a timeout for receiving packets from the charger (if there is no data being received from the charger for a given time, the connection loss flag is set), millisecond; 141 141 * Charge voltage – maximum charging voltage, V; 142 142 * Charge current – maximum charging current, A; 143 -* Current rize time, second; 144 144 * Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established. 145 145 146 146 Algorithm for working with the charger: ... ... @@ -395,8 +395,6 @@ 395 395 * Battery ID; 396 396 * Battery serial number. 397 397 398 -TBA 399 - 400 400 (% class="box infomessage" %) 401 401 ((( 402 402 **Note:** Dependence of the thermal derate from the battery and contactor temperature is linear. The system sends maximum value of the thermal derate among values calculated for the battery temperature and contactor temperature. ... ... @@ -644,11 +644,9 @@ 644 644 645 645 Communication parameters with the Main X are configured in the "External equipment → BMS → Main X" section: 646 646 647 -[[image:1735228238119-343.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="82" width="800"]]644 +[[image:1735228238119-343.png]] 648 648 649 649 In this section: 650 650 651 651 * Enable – a flag to enable communication with the BMS Main X; 652 -* Receive timeout – a timeout for receiving packets from the BMS Main X (if no data is being received from the BMS Main X during this time, the “Inhibit charging“ and “Inhibit discharging” signals may be generated), millisecond; 653 -* Set the 'Inhibit charging' signal if BMS Main X is offline; 654 -* Set the 'Inhibit discharging' signal if BMS Main X is offline; 649 +* Receive timeout – a timeout for receiving packets from the BMS Main X (if no data is being received from the BMS Main X during this time, the “Inhibit charging“ and “Inhibit discharging” signals may be generated), millisecond.