Changes for page 3.5 External equipment
Last modified by Admin on 2025/06/19 12:32
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -140,6 +140,7 @@ 140 140 * Receive timeout – a timeout for receiving packets from the charger (if there is no data being received from the charger for a given time, the connection loss flag is set), millisecond; 141 141 * Charge voltage – maximum charging voltage, V; 142 142 * Charge current – maximum charging current, A; 143 +* Current rize time, second; 143 143 * Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established. 144 144 145 145 Algorithm for working with the charger: ... ... @@ -284,7 +284,7 @@ 284 284 * Number of retries to restart nominal charge – number of retries to restart nominal charge after connection loss with charger; 285 285 * Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established. 286 286 287 -=== Sunny Island inverter === 288 +=== SMA Sunny Island inverter === 288 288 289 289 To change the communication parameters with an SMA Sunny Island inverter, select the "External equipment → Inverters and loads → SMA Sunny Island inverter" section: 290 290 ... ... @@ -355,7 +355,7 @@ 355 355 356 356 To change communication parameters with HYG Class I-III equipment, select the "External equipment → Trucks and Vehicles → HYG Class I-III truck" section: 357 357 358 -[[image:1735 227832802-527.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="337" width="800"]]359 +[[image:1750335865762-266.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="369" width="800"]] 359 359 360 360 In this section: 361 361 ... ... @@ -372,6 +372,8 @@ 372 372 * Heartbeat period – Heartbeat sending period, millisecond; 373 373 * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “HYG offline“ flag is set), millisecond; at a value of 0 milliseconds, the "HYG offline" error does not occur; 374 374 * Prevent discharging on the “Charger connected” signal and the "HYG offline" error – a flag to forbid discharging if the “Charger connected” signal presents and "HYG offline" error is generated; 376 +* Do not set the 'HYG offline' error if the 'Charger connected' is present – flag to prevent the "HYG offline" error from occurring if the "Charger connected" signal is set (see the "External equipment - Trucks and Vehicles - HYG Class I-III truck" section); 377 +* Wait for the confirmation from the truck before closing the charging contactor – flag that controls whether to wait for confirmation from the HYG truck or not, to allow the battery to be charged; 375 375 * Maximum voltage, V; 376 376 * Minimum voltage, V; 377 377 * Maximum charge current, А; ... ... @@ -412,7 +412,7 @@ 412 412 413 413 To change communication parameters with a Combilift forklift, select the "External equipment → Trucks and Vehicles → Combilift truck" section: 414 414 415 -[[image:1733 330972246-129.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="171" width="800"]]418 +[[image:1750336011634-554.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="159" width="800"]] 416 416 417 417 In this section: 418 418 ... ... @@ -425,6 +425,7 @@ 425 425 * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “Combilift offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Combilift offline" error does not occur; 426 426 * Inhibit charging on the "Combilift offline" error – a flag to forbid charging if the "Combilift offline" error is generated; 427 427 * Inhibit discharging on "Combilift offline" error – a flag to forbid discharging if the "Combilift offline" error is generated; 431 +* Do not set the "Combilift offline" error on the "Charger connected" signal; 428 428 * SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %; 429 429 * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %; 430 430 * Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to forklift;
- 1750335865762-266.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +73.6 KB - Content
- 1750336011634-554.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.1 KB - Content