Changes for page 3.5 External equipment

Last modified by Admin on 2025/06/19 12:32

From version 18.1
edited by Admin
on 2025/02/11 14:52
Change comment: There is no comment for this version
To version 20.1
edited by Admin
on 2025/02/26 14:43
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -140,6 +140,7 @@
140 140  * Receive timeout – a timeout for receiving packets from the charger (if there is no data being received from the charger for a given time, the connection loss flag is set), millisecond;
141 141  * Charge voltage – maximum charging voltage, V;
142 142  * Charge current – maximum charging current, A;
143 +* Current rize time, second;
143 143  * Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established.
144 144  
145 145  Algorithm for working with the charger:
... ... @@ -284,7 +284,7 @@
284 284  * Number of retries to restart nominal charge – number of retries to restart nominal charge after connection loss with charger;
285 285  * Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established.
286 286  
287 -=== Sunny Island inverter ===
288 +=== SMA Sunny Island inverter ===
288 288  
289 289  To change the communication parameters with an SMA Sunny Island inverter, select the "External equipment → Inverters and loads → SMA Sunny Island inverter" section:
290 290  
... ... @@ -425,6 +425,7 @@
425 425  * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “Combilift offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Combilift offline" error does not occur;
426 426  * Inhibit charging on the "Combilift offline" error – a flag to forbid charging if the "Combilift offline" error is generated;
427 427  * Inhibit discharging on "Combilift offline" error – a flag to forbid discharging if the "Combilift offline" error is generated;
429 +* Do not set the "Combilift offline" error on the "Charger connected" signal;
428 428  * SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %;
429 429  * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %;
430 430  * Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to forklift;