Changes for page 3.5 External equipment

Last modified by Admin on 2025/06/19 12:32

From version 15.1
edited by Admin
on 2024/12/26 16:47
Change comment: There is no comment for this version
To version 10.1
edited by Admin
on 2024/12/26 15:48
Change comment: Uploaded new attachment "1735228139582-964.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -6,8 +6,6 @@
6 6  
7 7  The BMS Main 3 device supports joint operation with chargers, inverters, indication panels, trucks and vehicle controllers.
8 8  
9 -TBA
10 -
11 11  === J1939 charger ===
12 12  
13 13  To change the parameters of communication with a charger using J1939 protocol, select the "External equipment → Chargers → J1939 charger" section:
... ... @@ -396,8 +396,6 @@
396 396  * Battery ID;
397 397  * Battery serial number.
398 398  
399 -TBA
400 -
401 401  (% class="box infomessage" %)
402 402  (((
403 403  **Note:** Dependence of the thermal derate from the battery and contactor temperature is linear. The system sends maximum value of the thermal derate among values calculated for the battery temperature and contactor temperature.
... ... @@ -443,7 +443,6 @@
443 443  
444 444  To change communication parameters with a Spirit AeroSystems truck, select the "External equipment → Trucks and Vehicles → Spirit AGV" section:
445 445  
446 -[[image:1735228139582-964.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="800"]]
447 447  
448 448  In this section:
449 449  
... ... @@ -456,6 +456,8 @@
456 456  ** V2;
457 457  * Node ID – a BMS identifier in the CANopen network;
458 458  * Receive timeout – a timeout for receiving packets from the truck (if no data is being received from the truck during this time, the “Spirit offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Spirit offline" error does not occur;
454 +* Inhibit charging on the "Spirit offline" error – a flag to forbid charging if the "Spirit offline" error is generated;
455 +* Inhibit discharging on the "Spirit offline" error – a flag to forbid discharging if the "Spirit offline" error is generated;
459 459  * SOC: Limited operation – a SOC level, at which the truck goes into a state of limited functionality, %;
460 460  * SOC: Lift lockout – a SOC level, at which the truck locks the lift, %;
461 461  * Send Heartbeat messages– a flag to enable generation of the Heartbeat messages to the truck;
... ... @@ -471,7 +471,7 @@
471 471  
472 472  To change communication parameters with the BMS Crown adapter, select the "External equipment → Trucks and Vehicles → Crown truck" section:
473 473  
474 -[[image:1735228176135-223.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="92" width="800"]]
471 +[[image:1733330972258-463.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="96" width="800"]]
475 475  
476 476  In this section:
477 477  
... ... @@ -481,7 +481,7 @@
481 481  ** CAN2 (int);
482 482  * Node ID – a BMS Crown identifier in the CANopen network;
483 483  * Delta voltage (tolerance) – a maximum deviation between the battery voltage and the voltage output by the Crown forklift system, V;
484 -* Prevent discharging on the EWS signal – a flag to inhibit reclosing the discharging contactor after sending EWS signal to the forklift.
481 +* Inhibit discharging on the EWS signal – a flag to inhibit reclosing the discharging contactor after sending EWS signal to the forklift.
485 485  
486 486  When working with the Crown forklift, the algorithm for controlling the discharging contactor is changed. The state machine used to switch the discharging contactor is described below.
487 487  
... ... @@ -645,11 +645,9 @@
645 645  
646 646  Communication parameters with the Main X are configured in the "External equipment → BMS → Main X" section:
647 647  
648 -[[image:1735228238119-343.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="82" width="800"]]
645 +[[image:1733330996006-677.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="106" width="800"]]
649 649  
650 650  In this section:
651 651  
652 652  * Enable – a flag to enable communication with the BMS Main X;
653 -* Receive timeout – a timeout for receiving packets from the BMS Main X (if no data is being received from the BMS Main X during this time, the “Inhibit charging“ and “Inhibit discharging” signals may be generated), millisecond;
654 -* Set the 'Inhibit charging' signal if BMS Main X is offline;
655 -* Set the 'Inhibit discharging' signal if BMS Main X is offline;
650 +* Receive timeout – a timeout for receiving packets from the BMS Main X (if no data is being received from the BMS Main X during this time, the “Inhibit charging“ and “Inhibit discharging” signals may be generated), millisecond.
1735228176135-223.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -18.0 KB
Content
1735228238119-343.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -17.6 KB
Content