Changes for page 3.5 External equipment
Last modified by Admin on 2025/06/19 12:32
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Content
-
... ... @@ -371,31 +371,19 @@ 371 371 * Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to the forklift; 372 372 * Heartbeat period – Heartbeat sending period, millisecond; 373 373 * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “HYG offline“ flag is set), millisecond; at a value of 0 milliseconds, the "HYG offline" error does not occur; 374 +* Inhibit charging on the "HYG offline" error – a flag to forbid charging if the "HYG offline" error is generated; 375 +* Inhibit discharging on the "HYG offline" error – a flag to forbid discharging if the "HYG offline" error is generated; 374 374 * Prevent discharging on the “Charger connected” signal and the "HYG offline" error – a flag to forbid discharging if the “Charger connected” signal presents and "HYG offline" error is generated; 375 375 * Maximum voltage, V; 376 376 * Minimum voltage, V; 377 377 * Maximum charge current, А; 378 378 * Maximum discharge current, А; 379 -* SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %; 380 380 * SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %; 382 +* SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %; 383 +* Thermal derate (0%): Battery temperature - a value of the battery temperature at which the thermal derate starts, °C; 381 381 * Thermal derate (0%): Contactor temperature - a value of the contactor temperature at which the thermal derate starts, °C; 382 -* Thermal derate (0%): High battery temperature - a value of the high battery temperature at which the thermal derate starts, °C; 383 -* Thermal derate (0%): Low battery temperature - a value of the low battery temperature at which the thermal derate starts, °C; 384 -* Nominal battery voltage, V; 385 -* Warranty SOH, %; 386 -* Warranty cycles; 387 -* Warranty hours; 388 -* Warranty usable energy, Wh; 389 -* Total energy + (initial value), Wh; 390 -* Total energy - (initial value), Wh; 391 -* Total energy regen (initial value), Wh; 392 -* Hours in service; 393 -* Battery brand; 394 -* Battery ID; 395 -* Battery serial number. 385 +* 396 396 397 -TBA 398 - 399 399 (% class="box infomessage" %) 400 400 ((( 401 401 **Note:** Dependence of the thermal derate from the battery and contactor temperature is linear. The system sends maximum value of the thermal derate among values calculated for the battery temperature and contactor temperature. ... ... @@ -441,7 +441,7 @@ 441 441 442 442 To change communication parameters with a Spirit AeroSystems truck, select the "External equipment → Trucks and Vehicles → Spirit AGV" section: 443 443 444 -[[image:173 5228139582-964.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="800"]]432 +[[image:1733330972257-158.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="182" width="800"]] 445 445 446 446 In this section: 447 447 ... ... @@ -454,6 +454,8 @@ 454 454 ** V2; 455 455 * Node ID – a BMS identifier in the CANopen network; 456 456 * Receive timeout – a timeout for receiving packets from the truck (if no data is being received from the truck during this time, the “Spirit offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Spirit offline" error does not occur; 445 +* Inhibit charging on the "Spirit offline" error – a flag to forbid charging if the "Spirit offline" error is generated; 446 +* Inhibit discharging on the "Spirit offline" error – a flag to forbid discharging if the "Spirit offline" error is generated; 457 457 * SOC: Limited operation – a SOC level, at which the truck goes into a state of limited functionality, %; 458 458 * SOC: Lift lockout – a SOC level, at which the truck locks the lift, %; 459 459 * Send Heartbeat messages– a flag to enable generation of the Heartbeat messages to the truck; ... ... @@ -469,7 +469,7 @@ 469 469 470 470 To change communication parameters with the BMS Crown adapter, select the "External equipment → Trucks and Vehicles → Crown truck" section: 471 471 472 -[[image:173 5228176135-223.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="92" width="800"]]462 +[[image:1733330972258-463.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="96" width="800"]] 473 473 474 474 In this section: 475 475 ... ... @@ -479,7 +479,7 @@ 479 479 ** CAN2 (int); 480 480 * Node ID – a BMS Crown identifier in the CANopen network; 481 481 * Delta voltage (tolerance) – a maximum deviation between the battery voltage and the voltage output by the Crown forklift system, V; 482 -* Prevent discharging on the EWS signal – a flag to inhibit reclosing the discharging contactor after sending EWS signal to the forklift.472 +* Inhibit discharging on the EWS signal – a flag to inhibit reclosing the discharging contactor after sending EWS signal to the forklift. 483 483 484 484 When working with the Crown forklift, the algorithm for controlling the discharging contactor is changed. The state machine used to switch the discharging contactor is described below. 485 485 ... ... @@ -643,11 +643,9 @@ 643 643 644 644 Communication parameters with the Main X are configured in the "External equipment → BMS → Main X" section: 645 645 646 -[[image:173 5228238119-343.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="82" width="800"]]636 +[[image:1733330996006-677.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="106" width="800"]] 647 647 648 648 In this section: 649 649 650 650 * Enable – a flag to enable communication with the BMS Main X; 651 -* Receive timeout – a timeout for receiving packets from the BMS Main X (if no data is being received from the BMS Main X during this time, the “Inhibit charging“ and “Inhibit discharging” signals may be generated), millisecond; 652 -* Set the 'Inhibit charging' signal if BMS Main X is offline; 653 -* Set the 'Inhibit discharging' signal if BMS Main X is offline; 641 +* Receive timeout – a timeout for receiving packets from the BMS Main X (if no data is being received from the BMS Main X during this time, the “Inhibit charging“ and “Inhibit discharging” signals may be generated), millisecond.
- 1735228139582-964.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -29.3 KB - Content
- 1735228176135-223.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -18.0 KB - Content
- 1735228238119-343.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -17.6 KB - Content