... ... @@ -1,5 +1,5 @@
1 1  (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 -= Settings =
2 += Configuration =
3 3  
4 4  (% data-numbered-headings-start="5" style="--numbered-headings-start: 4;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
5 5  == External equipment ==
... ... @@ -93,7 +93,7 @@
93 93  
94 94  (% class="box warningmessage" %)
95 95  (((
96 -**Warning! **To work properly with the charger, it is necessary to turn on sending synchronization messages over the CANopen network (see [[CAN1>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.6 Connectivity.WebHome||anchor="HCAN1"]]).
96 +**Warning! **To work properly with the charger, it is necessary to turn on sending synchronization messages over the CANopen network (see [[CAN2 (int)>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.6 Connectivity.WebHome||anchor="HCAN2int"]]).
97 97  )))
98 98  
99 99  (% class="box infomessage" %)
... ... @@ -140,6 +140,7 @@
140 140  * Receive timeout – a timeout for receiving packets from the charger (if there is no data being received from the charger for a given time, the connection loss flag is set), millisecond;
141 141  * Charge voltage – maximum charging voltage, V;
142 142  * Charge current – maximum charging current, A;
143 +* Current rize time, second;
143 143  * Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established.
144 144  
145 145  Algorithm for working with the charger:
... ... @@ -284,7 +284,7 @@
284 284  * Number of retries to restart nominal charge – number of retries to restart nominal charge after connection loss with charger;
285 285  * Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established.
286 286  
287 -=== Sunny Island inverter ===
288 +=== SMA Sunny Island inverter ===
288 288  
289 289  To change the communication parameters with an SMA Sunny Island inverter, select the "External equipment → Inverters and loads → SMA Sunny Island inverter" section:
290 290  
... ... @@ -355,7 +355,7 @@
355 355  
356 356  To change communication parameters with HYG Class I-III equipment, select the "External equipment → Trucks and Vehicles → HYG Class I-III truck" section:
357 357  
358 -[[image:1735227832802-527.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="337" width="800"]]
359 +[[image:1750335865762-266.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="369" width="800"]]
359 359  
360 360  In this section:
361 361  
... ... @@ -372,6 +372,8 @@
372 372  * Heartbeat period – Heartbeat sending period, millisecond;
373 373  * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “HYG offline“ flag is set), millisecond; at a value of 0 milliseconds, the "HYG offline" error does not occur;
374 374  * Prevent discharging on the “Charger connected” signal and the "HYG offline" error – a flag to forbid discharging if the “Charger connected” signal presents and "HYG offline" error is generated;
376 +* Do not set the 'HYG offline' error if the 'Charger connected' is present;
377 +* Wait for the confirmation from the truck before closing the charging contactor;
375 375  * Maximum voltage, V;
376 376  * Minimum voltage, V;
377 377  * Maximum charge current, А;
... ... @@ -394,6 +394,8 @@
394 394  * Battery ID;
395 395  * Battery serial number.
396 396  
400 +TBA
401 +
397 397  (% class="box infomessage" %)
398 398  (((
399 399  **Note:** Dependence of the thermal derate from the battery and contactor temperature is linear. The system sends maximum value of the thermal derate among values calculated for the battery temperature and contactor temperature.
... ... @@ -423,6 +423,7 @@
423 423  * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “Combilift offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Combilift offline" error does not occur;
424 424  * Inhibit charging on the "Combilift offline" error – a flag to forbid charging if the "Combilift offline" error is generated;
425 425  * Inhibit discharging on "Combilift offline" error – a flag to forbid discharging if the "Combilift offline" error is generated;
431 +* Do not set the "Combilift offline" error on the "Charger connected" signal;
426 426  * SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %;
427 427  * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %;
428 428  * Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to forklift;
1750335865762-266.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +73.6 KB
Content