Changes for page 3.5 External equipment
Last modified by Admin on 2025/06/19 12:32
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Settings=2 += Configuration = 3 3 4 4 (% data-numbered-headings-start="5" style="--numbered-headings-start: 4;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 5 == External equipment == ... ... @@ -93,7 +93,7 @@ 93 93 94 94 (% class="box warningmessage" %) 95 95 ((( 96 -**Warning! **To work properly with the charger, it is necessary to turn on sending synchronization messages over the CANopen network (see [[CAN 1>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.6 Connectivity.WebHome||anchor="HCAN1"]]).96 +**Warning! **To work properly with the charger, it is necessary to turn on sending synchronization messages over the CANopen network (see [[CAN2 (int)>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.6 Connectivity.WebHome||anchor="HCAN2int"]]). 97 97 ))) 98 98 99 99 (% class="box infomessage" %) ... ... @@ -140,6 +140,7 @@ 140 140 * Receive timeout – a timeout for receiving packets from the charger (if there is no data being received from the charger for a given time, the connection loss flag is set), millisecond; 141 141 * Charge voltage – maximum charging voltage, V; 142 142 * Charge current – maximum charging current, A; 143 +* Current rize time, second; 143 143 * Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established. 144 144 145 145 Algorithm for working with the charger: ... ... @@ -284,7 +284,7 @@ 284 284 * Number of retries to restart nominal charge – number of retries to restart nominal charge after connection loss with charger; 285 285 * Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established. 286 286 287 -=== Sunny Island inverter === 288 +=== SMA Sunny Island inverter === 288 288 289 289 To change the communication parameters with an SMA Sunny Island inverter, select the "External equipment → Inverters and loads → SMA Sunny Island inverter" section: 290 290 ... ... @@ -394,6 +394,8 @@ 394 394 * Battery ID; 395 395 * Battery serial number. 396 396 398 +TBA 399 + 397 397 (% class="box infomessage" %) 398 398 ((( 399 399 **Note:** Dependence of the thermal derate from the battery and contactor temperature is linear. The system sends maximum value of the thermal derate among values calculated for the battery temperature and contactor temperature. ... ... @@ -423,6 +423,7 @@ 423 423 * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “Combilift offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Combilift offline" error does not occur; 424 424 * Inhibit charging on the "Combilift offline" error – a flag to forbid charging if the "Combilift offline" error is generated; 425 425 * Inhibit discharging on "Combilift offline" error – a flag to forbid discharging if the "Combilift offline" error is generated; 429 +* Do not set the "Combilift offline" error on the "Charger connected" signal; 426 426 * SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %; 427 427 * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %; 428 428 * Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to forklift;