Changes for page 3.5 External equipment
Last modified by Admin on 2025/06/19 12:32
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -394,6 +394,8 @@ 394 394 * Battery ID; 395 395 * Battery serial number. 396 396 397 +TBA 398 + 397 397 (% class="box infomessage" %) 398 398 ((( 399 399 **Note:** Dependence of the thermal derate from the battery and contactor temperature is linear. The system sends maximum value of the thermal derate among values calculated for the battery temperature and contactor temperature. ... ... @@ -439,6 +439,7 @@ 439 439 440 440 To change communication parameters with a Spirit AeroSystems truck, select the "External equipment → Trucks and Vehicles → Spirit AGV" section: 441 441 444 +[[image:1735228139582-964.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="800"]] 442 442 443 443 In this section: 444 444 ... ... @@ -451,8 +451,6 @@ 451 451 ** V2; 452 452 * Node ID – a BMS identifier in the CANopen network; 453 453 * Receive timeout – a timeout for receiving packets from the truck (if no data is being received from the truck during this time, the “Spirit offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Spirit offline" error does not occur; 454 -* Inhibit charging on the "Spirit offline" error – a flag to forbid charging if the "Spirit offline" error is generated; 455 -* Inhibit discharging on the "Spirit offline" error – a flag to forbid discharging if the "Spirit offline" error is generated; 456 456 * SOC: Limited operation – a SOC level, at which the truck goes into a state of limited functionality, %; 457 457 * SOC: Lift lockout – a SOC level, at which the truck locks the lift, %; 458 458 * Send Heartbeat messages– a flag to enable generation of the Heartbeat messages to the truck; ... ... @@ -468,7 +468,7 @@ 468 468 469 469 To change communication parameters with the BMS Crown adapter, select the "External equipment → Trucks and Vehicles → Crown truck" section: 470 470 471 -[[image:173 3330972258-463.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="96" width="800"]]472 +[[image:1735228176135-223.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="92" width="800"]] 472 472 473 473 In this section: 474 474 ... ... @@ -478,7 +478,7 @@ 478 478 ** CAN2 (int); 479 479 * Node ID – a BMS Crown identifier in the CANopen network; 480 480 * Delta voltage (tolerance) – a maximum deviation between the battery voltage and the voltage output by the Crown forklift system, V; 481 -* Inhibit discharging on the EWS signal – a flag to inhibit reclosing the discharging contactor after sending EWS signal to the forklift.482 +* Prevent discharging on the EWS signal – a flag to inhibit reclosing the discharging contactor after sending EWS signal to the forklift. 482 482 483 483 When working with the Crown forklift, the algorithm for controlling the discharging contactor is changed. The state machine used to switch the discharging contactor is described below. 484 484 ... ... @@ -642,9 +642,11 @@ 642 642 643 643 Communication parameters with the Main X are configured in the "External equipment → BMS → Main X" section: 644 644 645 -[[image:1733 330996006-677.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="106" width="800"]]646 +[[image:1735228238119-343.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="82" width="800"]] 646 646 647 647 In this section: 648 648 649 649 * Enable – a flag to enable communication with the BMS Main X; 650 -* Receive timeout – a timeout for receiving packets from the BMS Main X (if no data is being received from the BMS Main X during this time, the “Inhibit charging“ and “Inhibit discharging” signals may be generated), millisecond. 651 +* Receive timeout – a timeout for receiving packets from the BMS Main X (if no data is being received from the BMS Main X during this time, the “Inhibit charging“ and “Inhibit discharging” signals may be generated), millisecond; 652 +* Set the 'Inhibit charging' signal if BMS Main X is offline; 653 +* Set the 'Inhibit discharging' signal if BMS Main X is offline;
- 1735228238119-343.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.6 KB - Content