Changes for page 3.5 External equipment

Last modified by Admin on 2025/06/19 12:32

From version 10.1
edited by Admin
on 2024/12/26 15:48
Change comment: Uploaded new attachment "1735228139582-964.png", version {1}
To version 9.2
edited by Admin
on 2024/12/26 15:45
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -371,28 +371,18 @@
371 371  * Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to the forklift;
372 372  * Heartbeat period – Heartbeat sending period, millisecond;
373 373  * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “HYG offline“ flag is set), millisecond; at a value of 0 milliseconds, the "HYG offline" error does not occur;
374 -* Prevent discharging on the “Charger connected” signal and the "HYG offline" error – a flag to forbid discharging if the “Charger connected” signal presents and "HYG offline" error is generated;
374 +* Inhibit charging on the "HYG offline" error – a flag to forbid charging if the "HYG offline" error is generated;
375 +* Inhibit discharging on the "HYG offline" error – a flag to forbid discharging if the "HYG offline" error is generated;
376 +* Prevendischarging on the “Charger connected” signal and the "HYG offline" error – a flag to forbid discharging if the “Charger connected” signal presents and "HYG offline" error is generated;
375 375  * Maximum voltage, V;
376 376  * Minimum voltage, V;
377 377  * Maximum charge current, А;
378 378  * Maximum discharge current, А;
379 -* SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %;
380 380  * SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %;
382 +* SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %;
383 +* Thermal derate (0%): Battery temperature - a value of the battery temperature at which the thermal derate starts, °C;
381 381  * Thermal derate (0%): Contactor temperature - a value of the contactor temperature at which the thermal derate starts, °C;
382 -* Thermal derate (0%): High battery temperature - a value of the high battery temperature at which the thermal derate starts, °C;
383 -* Thermal derate (0%): Low battery temperature - a value of the low battery temperature at which the thermal derate starts, °C;
384 -* Nominal battery voltage, V;
385 -* Warranty SOH, %;
386 -* Warranty cycles;
387 -* Warranty hours;
388 -* Warranty usable energy, Wh;
389 -* Total energy + (initial value), Wh;
390 -* Total energy - (initial value), Wh;
391 -* Total energy regen (initial value), Wh;
392 -* Hours in service;
393 -* Battery brand;
394 -* Battery ID;
395 -* Battery serial number.
385 +*
396 396  
397 397  (% class="box infomessage" %)
398 398  (((
... ... @@ -439,6 +439,7 @@
439 439  
440 440  To change communication parameters with a Spirit AeroSystems truck, select the "External equipment → Trucks and Vehicles → Spirit AGV" section:
441 441  
432 +[[image:1733330972257-158.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="182" width="800"]]
442 442  
443 443  In this section:
444 444  
1735228139582-964.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -29.3 KB
Content