... ... @@ -1,1 +1,1 @@
1 -drafts.bms-main-3.3\. Settings.WebHome
1 +Battery management systems.BMS Main 3.3\. Configuration.WebHome
Content
... ... @@ -1,16 +1,16 @@
1 -
1 +(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 += Configuration =
2 2  
4 +(% data-numbered-headings-start="5" style="--numbered-headings-start: 4;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
5 +== External equipment ==
3 3  
4 -The BMS Main 3 device supports joint operation with chargers, inverters, indication panels, trucks and vehicle controllers.
7 +The BMS Main 3 device supports joint operation with chargers, inverters, indication panels, trucks and vehicle controllers.
5 5  
9 +=== J1939 charger ===
6 6  
7 -1.
8 -11.
9 -111. J1939 charger
10 -
11 11  To change the parameters of communication with a charger using J1939 protocol, select the "External equipment → Chargers → J1939 charger" section:
12 12  
13 -[[image:1733330925860-611.png]]
13 +[[image:1733330925860-611.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="191" width="800"]]
14 14  
15 15  In this section:
16 16  
... ... @@ -41,16 +41,13 @@
41 41  
42 42  Algorithm for working with the charger:
43 43  
44 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11).
44 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]]).
45 45  
46 +=== Eltek charger ===
46 46  
47 -1.
48 -11.
49 -111. Eltek charger
50 -
51 51  To change the communication parameters with an Eltek charger, select the "External equipment → Chargers → Eltek charger" section:
52 52  
53 -[[image:1733330925864-261.png]]
50 +[[image:1733330925864-261.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="129" width="800"]]
54 54  
55 55  In this section:
56 56  
... ... @@ -67,16 +67,13 @@
67 67  
68 68  Algorithm for working with the charger:
69 69  
70 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11).
67 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]]).
71 71  
69 +=== MicroPower charger ===
72 72  
73 -1.
74 -11.
75 -111. MicroPower charger
76 -
77 77  To change the parameters of communication with a MicroPower charger, select the "External equipment → Chargers → MicroPower charger" section:
78 78  
79 -[[image:1733330925865-294.png]]
73 +[[image:1733330925865-294.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="149" width="800"]]
80 80  
81 81  In this section:
82 82  
... ... @@ -95,20 +95,23 @@
95 95  
96 96  Algorithm for working with the charger:
97 97  
98 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11).
92 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]]).
99 99  
100 -**Warning! To work properly with the charger, it is necessary to turn on sending synchronization messages over the CANopen network (see section 2.5.2).**
94 +(% class="box warningmessage" %)
95 +(((
96 +**Warning! **To work properly with the charger, it is necessary to turn on sending synchronization messages over the CANopen network (see [[CAN2 (int)>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.6 Connectivity.WebHome||anchor="HCAN2int"]]).
97 +)))
101 101  
102 -**After changing the settings, restart the BMS Main 3 device.**
99 +(% class="box infomessage" %)
100 +(((
101 +After changing the settings, restart the BMS Main 3 device.
102 +)))
103 103  
104 +=== S.P.E. charger ===
104 104  
105 -1.
106 -11.
107 -111. S.P.E. charger
108 -
109 109  To change the parameters of communication with an S.P.E. charger, select the "External equipment → Chargers → SPE charger" section:
110 110  
111 -[[image:1733330934850-187.png]]
108 +[[image:1733330934850-187.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="120" width="800"]]
112 112  
113 113  In this section:
114 114  
... ... @@ -124,16 +124,13 @@
124 124  
125 125  Algorithm for working with the charger:
126 126  
127 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11).
124 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]]).
128 128  
126 +=== Bassi charger ===
129 129  
130 -1.
131 -11.
132 -111. Bassi charger
133 -
134 134  To change the parameters of communication with a Bassi charger, select the "External equipment → Chargers → Bassi charger" section:
135 135  
136 -[[image:1733330934853-223.png]]
130 +[[image:1733330934853-223.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]
137 137  
138 138  In this section:
139 139  
... ... @@ -146,22 +146,23 @@
146 146  * Receive timeout – a timeout for receiving packets from the charger (if there is no data being received from the charger for a given time, the connection loss flag is set), millisecond;
147 147  * Charge voltage – maximum charging voltage, V;
148 148  * Charge current – maximum charging current, A;
143 +* Current rize time, second;
149 149  * Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established.
150 150  
151 151  Algorithm for working with the charger:
152 152  
153 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11).
148 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]]).
154 154  
155 -**After changing the settings, restart the BMS Main 3 device.**
150 +(% class="box infomessage" %)
151 +(((
152 +After changing the settings, restart the BMS Main 3 device.
153 +)))
156 156  
155 +=== ATIB charger ===
157 157  
158 -1.
159 -11.
160 -111. ATIB charger
161 -
162 162  To change the parameters of communication with an ATIB Elettronica charger, select the "External equipment → Chargers → ATIB Elettronica charger" section:
163 163  
164 -[[image:1733330934855-541.png]]
159 +[[image:1733330934855-541.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="116" width="800"]]
165 165  
166 166  In this section:
167 167  
... ... @@ -177,17 +177,18 @@
177 177  
178 178  Algorithm for working with the charger:
179 179  
180 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11).
175 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]]).
181 181  
182 -**After changing the settings, restart the BMS Main 3 device.**
177 +(% class="box infomessage" %)
178 +(((
179 +After changing the settings, restart the BMS Main 3 device.
180 +)))
183 183  
184 -1.
185 -11.
186 -111. Fronius charger
182 +=== Fronius charger ===
187 187  
188 188  To change the parameters of communication with a Fronius charger, select the "External equipment → Chargers → Fronius charger" section:
189 189  
190 -[[image:1733330947593-954.png]]
186 +[[image:1733330947593-954.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="139" width="800"]]
191 191  
192 192  In this section:
193 193  
... ... @@ -205,18 +205,18 @@
205 205  
206 206  Algorithm for working with the charger:
207 207  
208 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11).
204 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]]).
209 209  
210 -**After changing the settings, restart the BMS Main 3 device.**
206 +(% class="box infomessage" %)
207 +(((
208 +After changing the settings, restart the BMS Main 3 device.
209 +)))
211 211  
211 +=== Webasto charger ===
212 212  
213 -1.
214 -11.
215 -111. Webasto charger
216 -
217 217  To change the parameters of communication with a Webasto charger, select the "External equipment → Chargers → Webasto charger" section:
218 218  
219 -[[image:1733330947595-790.png]]
215 +[[image:1733330947595-790.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="107" width="800"]]
220 220  
221 221  In this section:
222 222  
... ... @@ -231,18 +231,18 @@
231 231  
232 232  Algorithm for working with the charger:
233 233  
234 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section 2.3.11).
230 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]]).
235 235  
236 -**After changing the settings, restart the BMS Main 3 device.**
232 +(% class="box infomessage" %)
233 +(((
234 +After changing the settings, restart the BMS Main 3 device.
235 +)))
237 237  
237 +=== Skytronic charger ===
238 238  
239 -1.
240 -11.
241 -111. Skytronic charger
242 -
243 243  To change the parameters of communication with a Skytronic charger, select the "External equipment → Chargers → Skytronic charger" section:
244 244  
245 -[[image:1733330947596-629.png]]
241 +[[image:1733330947596-629.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="106" width="800"]]
246 246  
247 247  In this section:
248 248  
... ... @@ -255,14 +255,11 @@
255 255  * Charge current – maximum charging current, A;
256 256  * Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established.
257 257  
254 +=== CCS Fast charge controller ===
258 258  
259 -1.
260 -11.
261 -111. CCS Fast charge controller
262 -
263 263  To change the parameters of communication with a CCS Fast charge controller, select the "External equipment → Chargers → CCS Fast charge controller" section:
264 264  
265 -[[image:1733330947597-290.png]]
258 +[[image:1733330947597-290.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="287" width="800"]]
266 266  
267 267  In this section:
268 268  
... ... @@ -292,13 +292,11 @@
292 292  * Number of retries to restart nominal charge – number of retries to restart nominal charge after connection loss with charger;
293 293  * Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established.
294 294  
295 -1.
296 -11.
297 -111. Sunny Island inverter
288 +=== SMA Sunny Island inverter ===
298 298  
299 299  To change the communication parameters with an SMA Sunny Island inverter, select the "External equipment → Inverters and loads → SMA Sunny Island inverter" section:
300 300  
301 -[[image:1733330959804-806.png]]
292 +[[image:1733330959804-806.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="141" width="800"]]
302 302  
303 303  In this section:
304 304  
... ... @@ -316,14 +316,11 @@
316 316  
317 317  When working with the Sunny Island inverter, the BMS Main 3 device sends messages with the values of voltage and charge/discharge current continuously with the period “Output period”: Charging voltage, Charging current, Discharging voltage, Discharging current.
318 318  
310 +=== Pylontech inverter ===
319 319  
320 -1.
321 -11.
322 -111. Pylontech inverter
323 -
324 324  To change the parameters of communication with a Pylontech inverter, select the "External equipment → Inverters and loads → Pylontech inverter" section:
325 325  
326 -[[image:1733330959806-653.png]]
314 +[[image:1733330959806-653.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="119" width="800"]]
327 327  
328 328  In this section:
329 329  
... ... @@ -339,14 +339,11 @@
339 339  * Discharge voltage (min) – minimum discharging voltage, V;
340 340  * Discharge current – maximum discharging current, А.
341 341  
330 +=== ASTOM load bank (cycling) ===
342 342  
343 -1.
344 -11.
345 -111. ASTOM load bank (cycling)
346 -
347 347  To change the parameters of communication with a ASTOM load bank, select the "External equipment → Inverters and loads → ASTOM load bank (cycling)" section:
348 348  
349 -[[image:1733330959806-204.png]]
334 +[[image:1733330959806-204.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="170" width="800"]]
350 350  
351 351  In this section:
352 352  
... ... @@ -365,16 +365,13 @@
365 365  * Voltage difference – difference between the minimum and maximum cell voltages for error to be generated and cycling to be stopped, V;
366 366  * Delay before setting the error – a delay before generating an error, second.
367 367  
353 +=== HYG Class I-III truck ===
368 368  
369 -1.
370 -11.
371 -111. HYG Class I-III truck
372 -
373 373  The HYG Class I-III equipment is installed on the forklifts by the group of companies HYSTER-YALE.
374 374  
375 375  To change communication parameters with HYG Class I-III equipment, select the "External equipment → Trucks and Vehicles → HYG Class I-III truck" section:
376 376  
377 -[[image:1733330959808-973.png]]
359 +[[image:1750335865762-266.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="369" width="800"]]
378 378  
379 379  In this section:
380 380  
... ... @@ -387,34 +387,53 @@
387 387  ** II-III;
388 388  ** I-III Gen.2;
389 389  * Node ID – an equipment identifier in the CANopen network;
372 +* Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to the forklift;
373 +* Heartbeat period – Heartbeat sending period, millisecond;
390 390  * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “HYG offline“ flag is set), millisecond; at a value of 0 milliseconds, the "HYG offline" error does not occur;
391 -* Inhibit charging on the "HYG offline" error – a flag to forbid charging if the "HYG offline" error is generated;
392 -* Inhibit discharging on the "HYG offline" error a flag to forbid discharging if the "HYG offline" error is generated;
393 -* Inhibit discharging on the “Charger connected” signal and the "HYG offline" error – a flag to forbid discharging if the “Charger connected” signal presents and "HYG offline" error is generated;
375 +* Prevent discharging on the “Charger connected” signal and the "HYG offline" error – a flag to forbid discharging if the “Charger connected” signal presents and "HYG offline" error is generated;
376 +* Do not set the 'HYG offline' error if the 'Charger connected' is present flag to prevent the "HYG offline" error from occurring if the "Charger connected" signal is set;
377 +* Wait for the confirmation from the truck before closing the charging contactor – flag that controls whether to wait for confirmation from the HYG truck or not, to allow the battery to be charged;
394 394  * Maximum voltage, V;
395 395  * Minimum voltage, V;
396 396  * Maximum charge current, А;
397 397  * Maximum discharge current, А;
398 -* SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %;
399 399  * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %;
400 -* Thermal derate (0%): Battery temperature - a value of the battery temperature at which the thermal derate starts, °C;
383 +* SOC: Limited operation a SOC level, at which the forklift goes into a state of limited functionality, %;
401 401  * Thermal derate (0%): Contactor temperature - a value of the contactor temperature at which the thermal derate starts, °C;
402 -* Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to the forklift;
403 -* Heartbeat period – Heartbeat sending period, millisecond.
385 +* Thermal derate (0%): High battery temperature - a value of the high battery temperature at which the thermal derate starts, °C;
386 +* Thermal derate (0%): Low battery temperature - a value of the low battery temperature at which the thermal derate starts, °C;
387 +* Nominal battery voltage, V;
388 +* Warranty SOH, %;
389 +* Warranty cycles;
390 +* Warranty hours;
391 +* Warranty usable energy, Wh;
392 +* Total energy + (initial value), Wh;
393 +* Total energy - (initial value), Wh;
394 +* Total energy regen (initial value), Wh;
395 +* Hours in service;
396 +* Battery brand;
397 +* Battery ID;
398 +* Battery serial number.
404 404  
405 -Note – Dependence of the thermal derate from the battery and contactor temperature is linear. The system sends maximum value of the thermal derate among values calculated for the battery temperature and contactor temperature.
400 +TBA
406 406  
402 +(% class="box infomessage" %)
403 +(((
404 +**Note:** Dependence of the thermal derate from the battery and contactor temperature is linear. The system sends maximum value of the thermal derate among values calculated for the battery temperature and contactor temperature.
405 +)))
406 +
407 407  The device with the identifier “Node ID” continuously transmits control commands to the forklift the with a period of 100 milliseconds.
408 408  
409 -**After changing the settings, restart the BMS Main 3 device.**
409 +(% class="box infomessage" %)
410 +(((
411 +After changing the settings, restart the BMS Main 3 device.
412 +)))
410 410  
411 -1.
412 -11.
413 -111. Combilift truck
414 +=== Combilift truck ===
414 414  
415 415  To change communication parameters with a Combilift forklift, select the "External equipment → Trucks and Vehicles → Combilift truck" section:
416 416  
417 -[[image:1733330972246-129.png]]
418 +[[image:1750336011634-554.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="159" width="800"]]
418 418  
419 419  In this section:
420 420  
... ... @@ -425,8 +425,8 @@
425 425  * Node ID – a BMS identifier in the CANopen network;
426 426  * Truck ID – a forklift identifier in the CANopen network;
427 427  * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “Combilift offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Combilift offline" error does not occur;
428 -* Inhibit charging on the "Combilift offline" error a flag to forbid charging if the "Combilift offline" error is generated;
429 -* Inhibit discharging on "Combilift offline" error a flag to forbid discharging if the "Combilift offline" error is generated;
429 +* Do not set the "Combilift offline" error on the "Charger connected" signal – flag to prevent the "Combilift offline" error from occurring if the "Charger connected" signal is set;
430 +* Wait for the confirmation from the truck before closing the charging contactor – flag that controls whether to wait for confirmation from the HYG truck or not, to allow the battery to be charged;
430 430  * SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %;
431 431  * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %;
432 432  * Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to forklift;
... ... @@ -434,16 +434,16 @@
434 434  
435 435  The device with the identifier “Node ID” continuously transmits control commands to the forklift with a period of 200 milliseconds.
436 436  
437 -**After changing the settings, restart the BMS Main 3 device.**
438 +(% class="box infomessage" %)
439 +(((
440 +After changing the settings, restart the BMS Main 3 device.
441 +)))
438 438  
443 +=== Spirit AGV ===
439 439  
440 -1.
441 -11.
442 -111. Spirit AGV
443 -
444 444  To change communication parameters with a Spirit AeroSystems truck, select the "External equipment → Trucks and Vehicles → Spirit AGV" section:
445 445  
446 -[[image:1733330972257-158.png]]
447 +[[image:1735228139582-964.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="800"]]
447 447  
448 448  In this section:
449 449  
... ... @@ -456,8 +456,6 @@
456 456  ** V2;
457 457  * Node ID – a BMS identifier in the CANopen network;
458 458  * Receive timeout – a timeout for receiving packets from the truck (if no data is being received from the truck during this time, the “Spirit offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Spirit offline" error does not occur;
459 -* Inhibit charging on the "Spirit offline" error – a flag to forbid charging if the "Spirit offline" error is generated;
460 -* Inhibit discharging on the "Spirit offline" error – a flag to forbid discharging if the "Spirit offline" error is generated;
461 461  * SOC: Limited operation – a SOC level, at which the truck goes into a state of limited functionality, %;
462 462  * SOC: Lift lockout – a SOC level, at which the truck locks the lift, %;
463 463  * Send Heartbeat messages– a flag to enable generation of the Heartbeat messages to the truck;
... ... @@ -467,16 +467,13 @@
467 467  
468 468  The device with the identifier “Node ID” continuously transmits control commands to the truck with a period of 100 milliseconds.
469 469  
469 +=== Crown truck ===
470 470  
471 -1.
472 -11.
473 -111. Crown truck
474 -
475 475  The BMS Main 3 device uses the BMS Crown adapter to control powering the Crown forklift.
476 476  
477 477  To change communication parameters with the BMS Crown adapter, select the "External equipment → Trucks and Vehicles → Crown truck" section:
478 478  
479 -[[image:1733330972258-463.png]]
475 +[[image:1735228176135-223.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="92" width="800"]]
480 480  
481 481  In this section:
482 482  
... ... @@ -486,7 +486,7 @@
486 486  ** CAN2 (int);
487 487  * Node ID – a BMS Crown identifier in the CANopen network;
488 488  * Delta voltage (tolerance) – a maximum deviation between the battery voltage and the voltage output by the Crown forklift system, V;
489 -* Inhibit discharging on the EWS signal – a flag to inhibit reclosing the discharging contactor after sending EWS signal to the forklift.
485 +* Prevent discharging on the EWS signal – a flag to inhibit reclosing the discharging contactor after sending EWS signal to the forklift.
490 490  
491 491  When working with the Crown forklift, the algorithm for controlling the discharging contactor is changed. The state machine used to switch the discharging contactor is described below.
492 492  
... ... @@ -536,18 +536,18 @@
536 536  
537 537  In this state, the discharging contactor is **open** and the "Crown error" is generated. If the "Inhibit discharging on the EWS signal" is not set, then after T = 10 seconds, the "Crown error" is cleared and the transition to the "Discharging Off" state is performed.
538 538  
539 -The value of T is set in the "Delay before starting discharging" field (see section 2.3.12).
535 +The value of T is set in the "Delay before starting discharging" field (see [[Discharge>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HDischarge"]]).
540 540  
541 -**After changing the settings, restart the BMS Main 3 device.**
537 +(% class="box infomessage" %)
538 +(((
539 +After changing the settings, restart the BMS Main 3 device.
540 +)))
542 542  
542 +=== ZiK truck ===
543 543  
544 -1.
545 -11.
546 -111. ZiK truck
547 -
548 548  To change communication parameters with a ZiK truck, select the "External equipment → Trucks and Vehicles → ZiK truck" section:
549 549  
550 -[[image:1733330985625-186.png]]
546 +[[image:1733330985625-186.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="800"]]
551 551  
552 552  In this section:
553 553  
... ... @@ -561,16 +561,16 @@
561 561  
562 562  The BMS with the identifier “Node ID” continuously transmits control commands to the truck with a period of 100 milliseconds.
563 563  
564 -**After changing the settings, restart the BMS Main 3 device.**
560 +(% class="box infomessage" %)
561 +(((
562 +After changing the settings, restart the BMS Main 3 device.
563 +)))
565 565  
565 +=== Evocargo Evo1.1 truck ===
566 566  
567 -1.
568 -11.
569 -111. Evocargo Evo1.1 truck
570 -
571 571  To change communication parameters with an Evocargo Evo1.1 truck, select the "External equipment → Trucks and Vehicles → Evocargo Evo1.1 truck" section:
572 572  
573 -[[image:1733330985627-145.png]]
569 +[[image:1733330985627-145.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="87" width="800"]]
574 574  
575 575  In this section:
576 576  
... ... @@ -577,14 +577,11 @@
577 577  * Enable – a flag to enable communication with the truck;
578 578  * Receive timeout – a timeout for receiving packets from the truck, millisecond.
579 579  
576 +=== BKM vehicle ===
580 580  
581 -1.
582 -11.
583 -111. BKM vehicle
584 -
585 585  To change communication parameters with a BKM vehicle, select the "External equipment → Trucks and Vehicles → BKM vehicle" section:
586 586  
587 -[[image:1733330985627-310.png]]
580 +[[image:1733330985627-310.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="90" width="800"]]
588 588  
589 589  In this section:
590 590  
... ... @@ -595,16 +595,13 @@
595 595  * Receive timeout – a timeout for receiving packets from the vehicle.
596 596  * Number of Logics in a pack.
597 597  
591 +=== Basic J1939 vehicle ===
598 598  
599 -1.
600 -11.
601 -111. Basic J1939 vehicle
602 -
603 603  The basic vehicle protocol J1939 is developed by Movicom Electric, and its description is available upon request. Using this protocol, information about the parameters of the battery can be obtained. The protocol also implements the management of battery operation modes.
604 604  
605 605  Communication parameters via the Basic J1939 protocol are configured in the “External equipment → Trucks and Vehicles → Basic J1939 vehicle” section:
606 606  
607 -[[image:1733330996003-704.png]]
597 +[[image:1733330996003-704.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="98" width="800"]]
608 608  
609 609  In this section:
610 610  
... ... @@ -616,14 +616,11 @@
616 616  * Receive vehicle messages – a flag to activate receiving vehicle messages;
617 617  * First vehicle message ID – an identifier of the first message of the vehicle in the J1939 network.
618 618  
609 +=== Bender iso165C ===
619 619  
620 -1.
621 -11.
622 -111. Bender iso165C
623 -
624 624  To change communication parameters with a Bender iso165C, select the "External equipment → IMD → Bender iso165C" section:
625 625  
626 -[[image:1733330996004-140.png]]
613 +[[image:1733330996004-140.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="108" width="800"]]
627 627  
628 628  In this section:
629 629  
... ... @@ -636,14 +636,11 @@
636 636  * Threshold to detect insulation error – threshold resistance value to generate the insulation error, Ohm;
637 637  * Threshold to detect insulation warning – threshold resistance value to generate the insulation warning, Ohm.
638 638  
626 +=== BMS IMD ===
639 639  
640 -1.
641 -11.
642 -111. BMS IMD
643 -
644 644  To change communication parameters with a BMS IMD, select the "External equipment → IMD → BMD IMD " section:
645 645  
646 -[[image:1733330996005-297.png]]
630 +[[image:1733330996005-297.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="109" width="800"]]
647 647  
648 648  In this section:
649 649  
... ... @@ -656,18 +656,17 @@
656 656  * Threshold to detect insulation alarm, Ohm;
657 657  * Threshold to detect insulation warning, Ohm.
658 658  
643 +=== Main X ===
659 659  
660 -1.
661 -11.
662 -111. Main X
663 -
664 664  The BMS Main 3 device can connect to BMS Main X strings controller.
665 665  
666 666  Communication parameters with the Main X are configured in the "External equipment → BMS → Main X" section:
667 667  
668 -[[image:1733330996006-677.png]]
649 +[[image:1735228238119-343.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="82" width="800"]]
669 669  
670 670  In this section:
671 671  
672 672  * Enable – a flag to enable communication with the BMS Main X;
673 -* Receive timeout – a timeout for receiving packets from the BMS Main X (if no data is being received from the BMS Main X during this time, the “Inhibit charging“ and “Inhibit discharging” signals may be generated), millisecond.
654 +* Receive timeout – a timeout for receiving packets from the BMS Main X (if no data is being received from the BMS Main X during this time, the “Inhibit charging“ and “Inhibit discharging” signals may be generated), millisecond;
655 +* Set the 'Inhibit charging' signal if BMS Main X is offline;
656 +* Set the 'Inhibit discharging' signal if BMS Main X is offline;
1735227832802-527.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +68.1 KB
Content
1735228139582-964.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +29.3 KB
Content
1735228176135-223.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +18.0 KB
Content
1735228238119-343.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +17.6 KB
Content
1750335865762-266.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +73.6 KB
Content
1750336011634-554.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +31.1 KB
Content
1750336137144-503.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +73.6 KB
Content
1750336294042-751.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +31.1 KB
Content