Changes for page 3.5 External equipment
Last modified by Admin on 2025/06/19 12:32
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 7 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - drafts.bms-main-3.3\.Settings.WebHome1 +Battery management systems.BMS Main 3.3\. Configuration.WebHome - Content
-
... ... @@ -1,16 +1,16 @@ 1 - 1 +(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 += Configuration = 2 2 4 +(% data-numbered-headings-start="5" style="--numbered-headings-start: 4;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 +== External equipment == 3 3 4 -The BMS Main 3 device 7 +The BMS Main 3 device supports joint operation with chargers, inverters, indication panels, trucks and vehicle controllers. 5 5 9 +=== J1939 charger === 6 6 7 -1. 8 -11. 9 -111. J1939 charger 10 - 11 11 To change the parameters of communication with a charger using J1939 protocol, select the "External equipment → Chargers → J1939 charger" section: 12 12 13 -[[image:1733330925860-611.png]] 13 +[[image:1733330925860-611.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="191" width="800"]] 14 14 15 15 In this section: 16 16 ... ... @@ -41,16 +41,13 @@ 41 41 42 42 Algorithm for working with the charger: 43 43 44 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section2.3.11).44 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]]). 45 45 46 +=== Eltek charger === 46 46 47 -1. 48 -11. 49 -111. Eltek charger 50 - 51 51 To change the communication parameters with an Eltek charger, select the "External equipment → Chargers → Eltek charger" section: 52 52 53 -[[image:1733330925864-261.png]] 50 +[[image:1733330925864-261.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="129" width="800"]] 54 54 55 55 In this section: 56 56 ... ... @@ -67,16 +67,13 @@ 67 67 68 68 Algorithm for working with the charger: 69 69 70 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section2.3.11).67 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]]). 71 71 69 +=== MicroPower charger === 72 72 73 -1. 74 -11. 75 -111. MicroPower charger 76 - 77 77 To change the parameters of communication with a MicroPower charger, select the "External equipment → Chargers → MicroPower charger" section: 78 78 79 -[[image:1733330925865-294.png]] 73 +[[image:1733330925865-294.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="149" width="800"]] 80 80 81 81 In this section: 82 82 ... ... @@ -95,20 +95,23 @@ 95 95 96 96 Algorithm for working with the charger: 97 97 98 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section2.3.11).92 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]]). 99 99 100 -**Warning! To work properly with the charger, it is necessary to turn on sending synchronization messages over the CANopen network (see section 2.5.2).** 94 +(% class="box warningmessage" %) 95 +((( 96 +**Warning! **To work properly with the charger, it is necessary to turn on sending synchronization messages over the CANopen network (see [[CAN2 (int)>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.6 Connectivity.WebHome||anchor="HCAN2int"]]). 97 +))) 101 101 102 -**After changing the settings, restart the BMS Main 3 device.** 99 +(% class="box infomessage" %) 100 +((( 101 +After changing the settings, restart the BMS Main 3 device. 102 +))) 103 103 104 +=== S.P.E. charger === 104 104 105 -1. 106 -11. 107 -111. S.P.E. charger 108 - 109 109 To change the parameters of communication with an S.P.E. charger, select the "External equipment → Chargers → SPE charger" section: 110 110 111 -[[image:1733330934850-187.png]] 108 +[[image:1733330934850-187.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="120" width="800"]] 112 112 113 113 In this section: 114 114 ... ... @@ -124,16 +124,13 @@ 124 124 125 125 Algorithm for working with the charger: 126 126 127 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section2.3.11).124 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]]). 128 128 126 +=== Bassi charger === 129 129 130 -1. 131 -11. 132 -111. Bassi charger 133 - 134 134 To change the parameters of communication with a Bassi charger, select the "External equipment → Chargers → Bassi charger" section: 135 135 136 -[[image:1733330934853-223.png]] 130 +[[image:1733330934853-223.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]] 137 137 138 138 In this section: 139 139 ... ... @@ -146,22 +146,23 @@ 146 146 * Receive timeout – a timeout for receiving packets from the charger (if there is no data being received from the charger for a given time, the connection loss flag is set), millisecond; 147 147 * Charge voltage – maximum charging voltage, V; 148 148 * Charge current – maximum charging current, A; 143 +* Current rize time, second; 149 149 * Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established. 150 150 151 151 Algorithm for working with the charger: 152 152 153 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section2.3.11).148 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]]). 154 154 155 -**After changing the settings, restart the BMS Main 3 device.** 150 +(% class="box infomessage" %) 151 +((( 152 +After changing the settings, restart the BMS Main 3 device. 153 +))) 156 156 155 +=== ATIB charger === 157 157 158 -1. 159 -11. 160 -111. ATIB charger 161 - 162 162 To change the parameters of communication with an ATIB Elettronica charger, select the "External equipment → Chargers → ATIB Elettronica charger" section: 163 163 164 -[[image:1733330934855-541.png]] 159 +[[image:1733330934855-541.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="116" width="800"]] 165 165 166 166 In this section: 167 167 ... ... @@ -177,17 +177,18 @@ 177 177 178 178 Algorithm for working with the charger: 179 179 180 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section2.3.11).175 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]]). 181 181 182 -**After changing the settings, restart the BMS Main 3 device.** 177 +(% class="box infomessage" %) 178 +((( 179 +After changing the settings, restart the BMS Main 3 device. 180 +))) 183 183 184 -1. 185 -11. 186 -111. Fronius charger 182 +=== Fronius charger === 187 187 188 188 To change the parameters of communication with a Fronius charger, select the "External equipment → Chargers → Fronius charger" section: 189 189 190 -[[image:1733330947593-954.png]] 186 +[[image:1733330947593-954.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="139" width="800"]] 191 191 192 192 In this section: 193 193 ... ... @@ -205,18 +205,18 @@ 205 205 206 206 Algorithm for working with the charger: 207 207 208 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section2.3.11).204 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]]). 209 209 210 -**After changing the settings, restart the BMS Main 3 device.** 206 +(% class="box infomessage" %) 207 +((( 208 +After changing the settings, restart the BMS Main 3 device. 209 +))) 211 211 211 +=== Webasto charger === 212 212 213 -1. 214 -11. 215 -111. Webasto charger 216 - 217 217 To change the parameters of communication with a Webasto charger, select the "External equipment → Chargers → Webasto charger" section: 218 218 219 -[[image:1733330947595-790.png]] 215 +[[image:1733330947595-790.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="107" width="800"]] 220 220 221 221 In this section: 222 222 ... ... @@ -231,18 +231,18 @@ 231 231 232 232 Algorithm for working with the charger: 233 233 234 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see section2.3.11).230 +The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]]). 235 235 236 -**After changing the settings, restart the BMS Main 3 device.** 232 +(% class="box infomessage" %) 233 +((( 234 +After changing the settings, restart the BMS Main 3 device. 235 +))) 237 237 237 +=== Skytronic charger === 238 238 239 -1. 240 -11. 241 -111. Skytronic charger 242 - 243 243 To change the parameters of communication with a Skytronic charger, select the "External equipment → Chargers → Skytronic charger" section: 244 244 245 -[[image:1733330947596-629.png]] 241 +[[image:1733330947596-629.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="106" width="800"]] 246 246 247 247 In this section: 248 248 ... ... @@ -255,14 +255,11 @@ 255 255 * Charge current – maximum charging current, A; 256 256 * Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established. 257 257 254 +=== CCS Fast charge controller === 258 258 259 -1. 260 -11. 261 -111. CCS Fast charge controller 262 - 263 263 To change the parameters of communication with a CCS Fast charge controller, select the "External equipment → Chargers → CCS Fast charge controller" section: 264 264 265 -[[image:1733330947597-290.png]] 258 +[[image:1733330947597-290.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="287" width="800"]] 266 266 267 267 In this section: 268 268 ... ... @@ -292,13 +292,11 @@ 292 292 * Number of retries to restart nominal charge – number of retries to restart nominal charge after connection loss with charger; 293 293 * Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established. 294 294 295 -1. 296 -11. 297 -111. Sunny Island inverter 288 +=== SMA Sunny Island inverter === 298 298 299 299 To change the communication parameters with an SMA Sunny Island inverter, select the "External equipment → Inverters and loads → SMA Sunny Island inverter" section: 300 300 301 -[[image:1733330959804-806.png]] 292 +[[image:1733330959804-806.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="141" width="800"]] 302 302 303 303 In this section: 304 304 ... ... @@ -316,14 +316,11 @@ 316 316 317 317 When working with the Sunny Island inverter, the BMS Main 3 device sends messages with the values of voltage and charge/discharge current continuously with the period “Output period”: Charging voltage, Charging current, Discharging voltage, Discharging current. 318 318 310 +=== Pylontech inverter === 319 319 320 -1. 321 -11. 322 -111. Pylontech inverter 323 - 324 324 To change the parameters of communication with a Pylontech inverter, select the "External equipment → Inverters and loads → Pylontech inverter" section: 325 325 326 -[[image:1733330959806-653.png]] 314 +[[image:1733330959806-653.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="119" width="800"]] 327 327 328 328 In this section: 329 329 ... ... @@ -339,14 +339,11 @@ 339 339 * Discharge voltage (min) – minimum discharging voltage, V; 340 340 * Discharge current – maximum discharging current, А. 341 341 330 +=== ASTOM load bank (cycling) === 342 342 343 -1. 344 -11. 345 -111. ASTOM load bank (cycling) 346 - 347 347 To change the parameters of communication with a ASTOM load bank, select the "External equipment → Inverters and loads → ASTOM load bank (cycling)" section: 348 348 349 -[[image:1733330959806-204.png]] 334 +[[image:1733330959806-204.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="170" width="800"]] 350 350 351 351 In this section: 352 352 ... ... @@ -365,16 +365,13 @@ 365 365 * Voltage difference – difference between the minimum and maximum cell voltages for error to be generated and cycling to be stopped, V; 366 366 * Delay before setting the error – a delay before generating an error, second. 367 367 353 +=== HYG Class I-III truck === 368 368 369 -1. 370 -11. 371 -111. HYG Class I-III truck 372 - 373 373 The HYG Class I-III equipment is installed on the forklifts by the group of companies HYSTER-YALE. 374 374 375 375 To change communication parameters with HYG Class I-III equipment, select the "External equipment → Trucks and Vehicles → HYG Class I-III truck" section: 376 376 377 -[[image:1733 330959808-973.png]]359 +[[image:1750335865762-266.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="369" width="800"]] 378 378 379 379 In this section: 380 380 ... ... @@ -387,34 +387,53 @@ 387 387 ** II-III; 388 388 ** I-III Gen.2; 389 389 * Node ID – an equipment identifier in the CANopen network; 372 +* Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to the forklift; 373 +* Heartbeat period – Heartbeat sending period, millisecond; 390 390 * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “HYG offline“ flag is set), millisecond; at a value of 0 milliseconds, the "HYG offline" error does not occur; 391 -* Inhibit charging on the "HYG offline" error – a flag to forbid charging if the "HYG offline" error is generated;392 -* Inhibitdischargingonthe"HYG offline"error–aflagtoforbiddischargingif the "HYG offline" error isgenerated;393 -* Inhibitdischargingonthe“Charger connected”signalandthe"HYG offline"error –aflag toforbid dischargingifthe“Chargerconnected” signalpresentsand "HYG offline"errorisgenerated;375 +* Prevent discharging on the “Charger connected” signal and the "HYG offline" error – a flag to forbid discharging if the “Charger connected” signal presents and "HYG offline" error is generated; 376 +* Do not set the 'HYG offline' error if the 'Charger connected' is present – flag to prevent the "HYG offline" error from occurring if the "Charger connected" signal is set (see the "External equipment - Trucks and Vehicles - HYG Class I-III truck" section); 377 +* Wait for the confirmation from the truck before closing the charging contactor – flag that controls whether to wait for confirmation from the HYG truck or not, to allow the battery to be charged; 394 394 * Maximum voltage, V; 395 395 * Minimum voltage, V; 396 396 * Maximum charge current, А; 397 397 * Maximum discharge current, А; 398 -* SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %; 399 399 * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %; 400 -* Thermal derate (0%):Batterytemperature-avalueof thebatterytemperature atwhich thethermalderatestarts,°C;383 +* SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %; 401 401 * Thermal derate (0%): Contactor temperature - a value of the contactor temperature at which the thermal derate starts, °C; 402 -* Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to the forklift; 403 -* Heartbeat period – Heartbeat sending period, millisecond. 385 +* Thermal derate (0%): High battery temperature - a value of the high battery temperature at which the thermal derate starts, °C; 386 +* Thermal derate (0%): Low battery temperature - a value of the low battery temperature at which the thermal derate starts, °C; 387 +* Nominal battery voltage, V; 388 +* Warranty SOH, %; 389 +* Warranty cycles; 390 +* Warranty hours; 391 +* Warranty usable energy, Wh; 392 +* Total energy + (initial value), Wh; 393 +* Total energy - (initial value), Wh; 394 +* Total energy regen (initial value), Wh; 395 +* Hours in service; 396 +* Battery brand; 397 +* Battery ID; 398 +* Battery serial number. 404 404 405 - Note – Dependence of the thermal derate from the battery and contactor temperature is linear.The system sends maximum value of the thermal derate among values calculated for the battery temperature and contactor temperature.400 +TBA 406 406 402 +(% class="box infomessage" %) 403 +((( 404 +**Note:** Dependence of the thermal derate from the battery and contactor temperature is linear. The system sends maximum value of the thermal derate among values calculated for the battery temperature and contactor temperature. 405 +))) 406 + 407 407 The device with the identifier “Node ID” continuously transmits control commands to the forklift the with a period of 100 milliseconds. 408 408 409 -**After changing the settings, restart the BMS Main 3 device.** 409 +(% class="box infomessage" %) 410 +((( 411 +After changing the settings, restart the BMS Main 3 device. 412 +))) 410 410 411 -1. 412 -11. 413 -111. Combilift truck 414 +=== Combilift truck === 414 414 415 415 To change communication parameters with a Combilift forklift, select the "External equipment → Trucks and Vehicles → Combilift truck" section: 416 416 417 -[[image:1733 330972246-129.png]]418 +[[image:1750336011634-554.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="159" width="800"]] 418 418 419 419 In this section: 420 420 ... ... @@ -427,6 +427,8 @@ 427 427 * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “Combilift offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Combilift offline" error does not occur; 428 428 * Inhibit charging on the "Combilift offline" error – a flag to forbid charging if the "Combilift offline" error is generated; 429 429 * Inhibit discharging on "Combilift offline" error – a flag to forbid discharging if the "Combilift offline" error is generated; 431 +* Do not set the "Combilift offline" error on the "Charger connected" signal – flag to prevent the "Combilift offline" error from occurring if the "Charger connected" signal is set; 432 +* Wait for the confirmation from the truck before closing the charging contactor – flag that controls whether to wait for confirmation from the HYG truck or not, to allow the battery to be charged; 430 430 * SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %; 431 431 * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %; 432 432 * Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to forklift; ... ... @@ -434,16 +434,16 @@ 434 434 435 435 The device with the identifier “Node ID” continuously transmits control commands to the forklift with a period of 200 milliseconds. 436 436 437 -**After changing the settings, restart the BMS Main 3 device.** 440 +(% class="box infomessage" %) 441 +((( 442 +After changing the settings, restart the BMS Main 3 device. 443 +))) 438 438 445 +=== Spirit AGV === 439 439 440 -1. 441 -11. 442 -111. Spirit AGV 443 - 444 444 To change communication parameters with a Spirit AeroSystems truck, select the "External equipment → Trucks and Vehicles → Spirit AGV" section: 445 445 446 -[[image:173 3330972257-158.png]]449 +[[image:1735228139582-964.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="800"]] 447 447 448 448 In this section: 449 449 ... ... @@ -456,8 +456,6 @@ 456 456 ** V2; 457 457 * Node ID – a BMS identifier in the CANopen network; 458 458 * Receive timeout – a timeout for receiving packets from the truck (if no data is being received from the truck during this time, the “Spirit offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Spirit offline" error does not occur; 459 -* Inhibit charging on the "Spirit offline" error – a flag to forbid charging if the "Spirit offline" error is generated; 460 -* Inhibit discharging on the "Spirit offline" error – a flag to forbid discharging if the "Spirit offline" error is generated; 461 461 * SOC: Limited operation – a SOC level, at which the truck goes into a state of limited functionality, %; 462 462 * SOC: Lift lockout – a SOC level, at which the truck locks the lift, %; 463 463 * Send Heartbeat messages– a flag to enable generation of the Heartbeat messages to the truck; ... ... @@ -467,16 +467,13 @@ 467 467 468 468 The device with the identifier “Node ID” continuously transmits control commands to the truck with a period of 100 milliseconds. 469 469 471 +=== Crown truck === 470 470 471 -1. 472 -11. 473 -111. Crown truck 474 - 475 475 The BMS Main 3 device uses the BMS Crown adapter to control powering the Crown forklift. 476 476 477 477 To change communication parameters with the BMS Crown adapter, select the "External equipment → Trucks and Vehicles → Crown truck" section: 478 478 479 -[[image:173 3330972258-463.png]]477 +[[image:1735228176135-223.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="92" width="800"]] 480 480 481 481 In this section: 482 482 ... ... @@ -486,7 +486,7 @@ 486 486 ** CAN2 (int); 487 487 * Node ID – a BMS Crown identifier in the CANopen network; 488 488 * Delta voltage (tolerance) – a maximum deviation between the battery voltage and the voltage output by the Crown forklift system, V; 489 -* Inhibit discharging on the EWS signal – a flag to inhibit reclosing the discharging contactor after sending EWS signal to the forklift.487 +* Prevent discharging on the EWS signal – a flag to inhibit reclosing the discharging contactor after sending EWS signal to the forklift. 490 490 491 491 When working with the Crown forklift, the algorithm for controlling the discharging contactor is changed. The state machine used to switch the discharging contactor is described below. 492 492 ... ... @@ -536,18 +536,18 @@ 536 536 537 537 In this state, the discharging contactor is **open** and the "Crown error" is generated. If the "Inhibit discharging on the EWS signal" is not set, then after T = 10 seconds, the "Crown error" is cleared and the transition to the "Discharging Off" state is performed. 538 538 539 -The value of T is set in the "Delay before starting discharging" field (see secti on2.3.12).537 +The value of T is set in the "Delay before starting discharging" field (see [[Discharge>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HDischarge"]]). 540 540 541 -**After changing the settings, restart the BMS Main 3 device.** 539 +(% class="box infomessage" %) 540 +((( 541 +After changing the settings, restart the BMS Main 3 device. 542 +))) 542 542 544 +=== ZiK truck === 543 543 544 -1. 545 -11. 546 -111. ZiK truck 547 - 548 548 To change communication parameters with a ZiK truck, select the "External equipment → Trucks and Vehicles → ZiK truck" section: 549 549 550 -[[image:1733330985625-186.png]] 548 +[[image:1733330985625-186.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="800"]] 551 551 552 552 In this section: 553 553 ... ... @@ -561,16 +561,16 @@ 561 561 562 562 The BMS with the identifier “Node ID” continuously transmits control commands to the truck with a period of 100 milliseconds. 563 563 564 -**After changing the settings, restart the BMS Main 3 device.** 562 +(% class="box infomessage" %) 563 +((( 564 +After changing the settings, restart the BMS Main 3 device. 565 +))) 565 565 567 +=== Evocargo Evo1.1 truck === 566 566 567 -1. 568 -11. 569 -111. Evocargo Evo1.1 truck 570 - 571 571 To change communication parameters with an Evocargo Evo1.1 truck, select the "External equipment → Trucks and Vehicles → Evocargo Evo1.1 truck" section: 572 572 573 -[[image:1733330985627-145.png]] 571 +[[image:1733330985627-145.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="87" width="800"]] 574 574 575 575 In this section: 576 576 ... ... @@ -577,14 +577,11 @@ 577 577 * Enable – a flag to enable communication with the truck; 578 578 * Receive timeout – a timeout for receiving packets from the truck, millisecond. 579 579 578 +=== BKM vehicle === 580 580 581 -1. 582 -11. 583 -111. BKM vehicle 584 - 585 585 To change communication parameters with a BKM vehicle, select the "External equipment → Trucks and Vehicles → BKM vehicle" section: 586 586 587 -[[image:1733330985627-310.png]] 582 +[[image:1733330985627-310.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="90" width="800"]] 588 588 589 589 In this section: 590 590 ... ... @@ -595,16 +595,13 @@ 595 595 * Receive timeout – a timeout for receiving packets from the vehicle. 596 596 * Number of Logics in a pack. 597 597 593 +=== Basic J1939 vehicle === 598 598 599 -1. 600 -11. 601 -111. Basic J1939 vehicle 602 - 603 603 The basic vehicle protocol J1939 is developed by Movicom Electric, and its description is available upon request. Using this protocol, information about the parameters of the battery can be obtained. The protocol also implements the management of battery operation modes. 604 604 605 605 Communication parameters via the Basic J1939 protocol are configured in the “External equipment → Trucks and Vehicles → Basic J1939 vehicle” section: 606 606 607 -[[image:1733330996003-704.png]] 599 +[[image:1733330996003-704.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="98" width="800"]] 608 608 609 609 In this section: 610 610 ... ... @@ -616,14 +616,11 @@ 616 616 * Receive vehicle messages – a flag to activate receiving vehicle messages; 617 617 * First vehicle message ID – an identifier of the first message of the vehicle in the J1939 network. 618 618 611 +=== Bender iso165C === 619 619 620 -1. 621 -11. 622 -111. Bender iso165C 623 - 624 624 To change communication parameters with a Bender iso165C, select the "External equipment → IMD → Bender iso165C" section: 625 625 626 -[[image:1733330996004-140.png]] 615 +[[image:1733330996004-140.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="108" width="800"]] 627 627 628 628 In this section: 629 629 ... ... @@ -636,14 +636,11 @@ 636 636 * Threshold to detect insulation error – threshold resistance value to generate the insulation error, Ohm; 637 637 * Threshold to detect insulation warning – threshold resistance value to generate the insulation warning, Ohm. 638 638 628 +=== BMS IMD === 639 639 640 -1. 641 -11. 642 -111. BMS IMD 643 - 644 644 To change communication parameters with a BMS IMD, select the "External equipment → IMD → BMD IMD " section: 645 645 646 -[[image:1733330996005-297.png]] 632 +[[image:1733330996005-297.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="109" width="800"]] 647 647 648 648 In this section: 649 649 ... ... @@ -656,18 +656,17 @@ 656 656 * Threshold to detect insulation alarm, Ohm; 657 657 * Threshold to detect insulation warning, Ohm. 658 658 645 +=== Main X === 659 659 660 -1. 661 -11. 662 -111. Main X 663 - 664 664 The BMS Main 3 device can connect to BMS Main X strings controller. 665 665 666 666 Communication parameters with the Main X are configured in the "External equipment → BMS → Main X" section: 667 667 668 -[[image:1733 330996006-677.png]]651 +[[image:1735228238119-343.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="82" width="800"]] 669 669 670 670 In this section: 671 671 672 672 * Enable – a flag to enable communication with the BMS Main X; 673 -* Receive timeout – a timeout for receiving packets from the BMS Main X (if no data is being received from the BMS Main X during this time, the “Inhibit charging“ and “Inhibit discharging” signals may be generated), millisecond. 656 +* Receive timeout – a timeout for receiving packets from the BMS Main X (if no data is being received from the BMS Main X during this time, the “Inhibit charging“ and “Inhibit discharging” signals may be generated), millisecond; 657 +* Set the 'Inhibit charging' signal if BMS Main X is offline; 658 +* Set the 'Inhibit discharging' signal if BMS Main X is offline;
- 1735227832802-527.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +68.1 KB - Content
- 1735228139582-964.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.3 KB - Content
- 1735228176135-223.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.0 KB - Content
- 1735228238119-343.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.6 KB - Content
- 1750335865762-266.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +73.6 KB - Content
- 1750336011634-554.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.1 KB - Content
- 1750336137144-503.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +73.6 KB - Content