Changes for page 3.3 Control

Last modified by Admin on 2026/04/30 15:56

From version 94.1
edited by Admin
on 2026/04/30 15:56
Change comment: There is no comment for this version
To version 90.1
edited by Admin
on 2026/04/30 13:56
Change comment: Uploaded new attachment "1777557373784-459.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -8,7 +8,7 @@
8 8  
9 9  To change the common BMS settings, select the "Control → Common settings" section:
10 10  
11 -[[image:1777557373784-459.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="180" width="800"]]
11 +[[image:1735054851946-552.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="105" width="800"]]
12 12  
13 13  In this section:
14 14  
... ... @@ -489,7 +489,7 @@
489 489  * **Errors 1, 2 to open the charging contactor** – bitfields to choose the errors which will open the charging contactor;
490 490  * **Use custom delays before stopping charging (on errors)** – a flag to enable manual settings of time delays T,,off,, for specific errors;
491 491  * **Custom delay: <error>** – delay for specific error, millisecond;
492 -* **Switch off the charging contactor on errors without delay** – a flag to protectively open the charging contactor without a delay. In the opposite case, when an error is detected, the charging contactor opens always with the delay “Delay before stopping charging”.
492 +* **Switch off the charging contactor on errors without delay** – a flag to protectively open the charging contactor without a delay. In the opposite case, when an error is detected, the charging contactor opens always with the delay “Delay before stopping charging”;
493 493  
494 494  === Discharge ===
495 495  
... ... @@ -707,7 +707,7 @@
707 707  * the battery voltage is below the minimum level;
708 708  * the “Charger connected” signal is cleared for 60 seconds.
709 709  
710 -The BMS Main 3 / BMS Main 2R device also shuts down the battery if it **stays for a long time **in the “Charging OFF”, “Discharging OFF”, “Relaxed (after charging)” or “Relaxed (after discharging)” state.
710 +The BMS Main 3 device also shuts down the battery if it **stays for a long time **in the “Charging OFF”, “Discharging OFF”, “Relaxed (after charging)” or “Relaxed (after discharging)” state.
711 711  
712 712  To change the parameters of the power down control, select the "Control → Power down" section:
713 713  
1777557391157-274.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -40.4 KB
Content