Changes for page 3.3 Control
Last modified by Admin on 2026/04/30 15:56
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -8,7 +8,7 @@ 8 8 9 9 To change the common BMS settings, select the "Control → Common settings" section: 10 10 11 -[[image:17 77557373784-459.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="180" width="800"]]11 +[[image:1735054851946-552.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="105" width="800"]] 12 12 13 13 In this section: 14 14 ... ... @@ -489,7 +489,7 @@ 489 489 * **Errors 1, 2 to open the charging contactor** – bitfields to choose the errors which will open the charging contactor; 490 490 * **Use custom delays before stopping charging (on errors)** – a flag to enable manual settings of time delays T,,off,, for specific errors; 491 491 * **Custom delay: <error>** – delay for specific error, millisecond; 492 -* **Switch off the charging contactor on errors without delay** – a flag to protectively open the charging contactor without a delay. In the opposite case, when an error is detected, the charging contactor opens always with the delay “Delay before stopping charging” .492 +* **Switch off the charging contactor on errors without delay** – a flag to protectively open the charging contactor without a delay. In the opposite case, when an error is detected, the charging contactor opens always with the delay “Delay before stopping charging”; 493 493 494 494 === Discharge === 495 495 ... ... @@ -542,16 +542,16 @@ 542 542 543 543 === Charge/Discharge === 544 544 545 -The BMS Main 3 / BMS Main 2R device can control the contactor, used in power line both used for connecting battery to charger and load, by using the "Charging/Discharging"signal.545 +The BMS Main 3 / BMS Main 2R device can control the contactor, used in power line both used for connecting battery to charger and load, by using the Charging/Discharging signal. 546 546 547 - "Charging/Discharging"signalhas three algorithms of operation:547 +Charge/Discharge contactor has three algorithms of operation: 548 548 549 -On **Dependent (on Charging and Discharging signals)** algorithm the "Charging/Discharging"signaldepends on Charge and Discharge controllers and equal to:549 +On **Dependent (on Charging and Discharging signals)** algorithm the charge/discharge contactor depends on Charge and Discharge controllers and behaves: 550 550 551 -* "Charging"signalif "Charging" signal is set;552 -* "Discharging"signalin other cases.551 +* as Charging contactor if "Charging" signal is set; 552 +* as Discharging contactor in other cases. 553 553 554 -When **Independent (Always) **algorithm is selected, the "Charging/Discharging"signalis always set. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals:554 +When **Independent (Always) **algorithm is selected, the charging/discharging contactor is always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals: 555 555 556 556 * Service reset 557 557 * Power down request ... ... @@ -558,12 +558,12 @@ 558 558 * Inhibit charging 559 559 * Inhibit discharging 560 560 561 -the Charging/Dischargingsignal iscleared.561 +the charging/discharging contactor opens. 562 562 563 -On **Independent (on Charge request or Discharge request)** algorithm "Charging/Discharging"signalis based on its own controller and performs as follows:563 +On **Independent (on Charge request or Discharge request)** algorithm charge/discharge contactor is based on its own controller and performs as follows: 564 564 565 -* if there is "Charge request" or "Discharge request" signal and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the Charging/Dischargingsignalisset;566 -* If the "Charge request" and"Discharge request" disappears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the"Charging/Discharging"signal iscleared.565 +* if there is "Charge request" or "Discharge request" signal and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the charging/discharging contactor closes; 566 +* If the "Charge request" or "Discharge request" disappears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the charging/discharging contactor opens. 567 567 568 568 (% class="box infomessage" %) 569 569 ((( ... ... @@ -584,7 +584,7 @@ 584 584 * **Delay before starting charging or discharging**, millisecond; 585 585 * **Delay before stopping charging or discharging**, millisecond; 586 586 * **Control the precharging contactor** – a flag that enables control of precharging contactor while closing the charge/discharge contactor; 587 -* **Emulate the "Charging" and "Discharging" signals** – a flag to enable generation of "Charging" and "Discharging" signals in Independet modewhen closingCharge/Discharge contactor. **DO NOT** use with enabled Charge and Discharge controllers;587 +* **Emulate the "Charging" and "Discharging" signals** – a flag to enable generation of "Charging" and "Discharging" signals when closing charge/discharge contactor; 588 588 * **Errors 1, 2 to prevent CHARGING through charging/discharging contactor, Errors 1, 2 to prevent DISCHARGING through charging/discharging contactor** – bitfields to choose the errors which will open the charging/discharging contactor. This bitfields are combined by bitwise OR and intended to separate settings for charging and discharging processes; 589 589 * **Errors 1, 2 which affect the contactor only if battery CHARGING is detected** – a bitfield to choose the errors which will trigger only if charging current is present. This bitfield is combined with "Errors 1, 2 to prevent CHARGING through charging/discharging contactor" by bitwise AND; 590 590 * **Errors 1, 2 which affect the contactor only if battery DISCHARGING is detected** – a bitfield to choose the errors which will trigger only if discharging current is present. This bitfield is combined with "Errors 1, 2 to prevent DISCHARGING through charging/discharging contactor" by bitwise AND; ... ... @@ -707,7 +707,7 @@ 707 707 * the battery voltage is below the minimum level; 708 708 * the “Charger connected” signal is cleared for 60 seconds. 709 709 710 -The BMS Main 3 / BMS Main 2Rdevice also shuts down the battery if it **stays for a long time **in the “Charging OFF”, “Discharging OFF”, “Relaxed (after charging)” or “Relaxed (after discharging)” state.710 +The BMS Main 3 device also shuts down the battery if it **stays for a long time **in the “Charging OFF”, “Discharging OFF”, “Relaxed (after charging)” or “Relaxed (after discharging)” state. 711 711 712 712 To change the parameters of the power down control, select the "Control → Power down" section: 713 713
- 1777557373784-459.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -40.4 KB - Content
- 1777557391157-274.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -40.4 KB - Content