Changes for page 3.3 Control
Last modified by Admin on 2026/04/30 15:56
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -489,7 +489,7 @@ 489 489 * **Errors 1, 2 to open the charging contactor** – bitfields to choose the errors which will open the charging contactor; 490 490 * **Use custom delays before stopping charging (on errors)** – a flag to enable manual settings of time delays T,,off,, for specific errors; 491 491 * **Custom delay: <error>** – delay for specific error, millisecond; 492 -* **Switch off the charging contactor on errors without delay** – a flag to protectively open the charging contactor without a delay. In the opposite case, when an error is detected, the charging contactor opens always with the delay “Delay before stopping charging” .492 +* **Switch off the charging contactor on errors without delay** – a flag to protectively open the charging contactor without a delay. In the opposite case, when an error is detected, the charging contactor opens always with the delay “Delay before stopping charging”; 493 493 494 494 === Discharge === 495 495