... ... @@ -70,8 +70,8 @@
70 70  
71 71  * Minimal SOC – the battery SOC is assumed to be the minimum SOC among the cells;
72 72  * Average SOC – the battery SOC is taken equal to the arithmetic average of the cell SOC;
73 -* Min-Max SOC – the battery SOC is calculated  based on the minimum and maximum SOC of the cells. Final SOC will be assumed as 100% if any cell
74 -* Max-Min SOC – the battery SOC is taken based on the minimum and maximum SOC of the cells.
73 +* Min-Max SOC – the battery SOC is calculated based on the minimum and maximum SOC of the cells. Final SOC will be assumed as 0% and 100% if any cell have 100% SOC
74 +* Max-Min SOC – the battery SOC is calculated based on the minimum and maximum SOC of the cells.
75 75  
76 76  Other parameters:
77 77