Changes for page 3.3 Control
Last modified by Admin on 2026/04/30 15:56
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -444,31 +444,31 @@ 444 444 445 445 === Charge === 446 446 447 -The rearetwosignalsthatserve charging the battery:"Charging" and "Allowcharging".Withthehelp of the"Allow charging" signal, the BMS commands the charger to start or stop charging.447 +The BMS Main 3 / BMS Main 2R device connect battery to the charger using the "Charging" signal. 448 448 449 449 BMS Main 3 / BMS Main 2R supports three charge control algorithms: 450 450 451 -If the "**Always on**" algorithm is selected, the "Сharging signals"and the "Allow charging"signals are alwaysclosed. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals:451 +If the "**Always on**" algorithm is selected, the "Сharging" signal is always set. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals: 452 452 453 453 * Service reset; 454 454 * Power down request; 455 455 * Inhibit charging, 456 456 457 - both signalsarecleared.457 +"Charging" signal is cleared. 458 458 459 459 When the algorithm "**On charger connected**" is selected, the control is performed as follows: 460 460 461 -* If there is a signal “Charger connected” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the "Charging" and the "Allow charging"signal are set;461 +* If there is a signal “Charger connected” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the "Charging" signal are set; 462 462 * If the signal “Charger connected” disappears or errors occur (see the "Errors 1, 2 ..." bitfields), the "Allow charging" signal is cleared and after the delay time T,,off,, the "Charging" signal is cleared. 463 463 464 464 When the "**On charge request**" algorithm selected, the control is performed as follows: 465 465 466 466 * If there is a signal “Charge request” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the "Charging" and the "Allow charging" signal are set; 467 -* If the signal “Charge request” disappears or errors occur (see the "Errors 1, 2 ..." bitfields), the allow chargingcontactoropens and after the delay time T,,off,, thechargingcontactoropens;467 +* If the signal “Charge request” disappears or errors occur (see the "Errors 1, 2 ..." bitfields), the "Allow charging" signal is cleared and after the delay time T,,off,, the "Charging" signal is cleared; 468 468 469 469 (% class="box infomessage" %) 470 470 ((( 471 -**Note: **when errors occur in the system, the **Charg e**contactoropenseither immediately or with the delay T,,off,, (depends on the settings described below).471 +**Note: **when errors occur in the system, the **"Charing" **signal is cleared either immediately or with the delay T,,off,, (depends on the settings described below). 472 472 ))) 473 473 474 474 To change the parameters of the battery charge control algorithm, select the "Control → Charge" section: ... ... @@ -493,26 +493,26 @@ 493 493 494 494 === Discharge === 495 495 496 -The BMS Main 3 / BMS Main 2R device con trols the discharging contactor to connect battery to the load.496 +The BMS Main 3 / BMS Main 2R device connect battery to the load using the "Discharging" signal. 497 497 498 498 BMS Main 3 / BMS Main 2R supports three algorithms to control battery discharging: 499 499 500 -When the algorithm "**Always on**" is selected, the dischargingcontactoris alwaysclosed. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals:500 +When the algorithm "**Always on**" is selected, the "Discharging" signal is always set. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals: 501 501 502 502 * Service reset 503 503 * Power down request 504 504 * Inhibit discharging 505 505 506 -the dischargingcontactoropens.506 +the "Discharging" signal is cleared. 507 507 508 508 If the algorithm "**On charger disconnected**" is selected, the control is performed as follows: 509 509 510 -* if there isnosignal“Charger connected”,thechargingcontactor isopenand there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, thedischargingcontactor closes;511 -* If the signal “Charger connected” appears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the dischargingcontactoropens.510 +* if there are no “Charger connected” and "Charging" signals and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the "Discharging" signal is set; 511 +* If the signal “Charger connected” appears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the "Discharging" signal is cleared. 512 512 513 513 When the "**On discharge request**" algorithm selected, the control is performed as follows: 514 514 515 -* if there is signal “Discharge request” ,the charging contactor is open and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, thedischargingcontactor closes;515 +* if there is signal “Discharge request” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the "Discharging" signal is set; 516 516 * If the signal “Discharge request” disappears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the discharging contactor opens. 517 517 518 518 (% class="box infomessage" %)