Changes for page 3.3 Control
Last modified by Admin on 2026/04/30 15:56
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -448,7 +448,7 @@ 448 448 449 449 BMS Main 3 / BMS Main 2R supports three charge control algorithms: 450 450 451 -If the "**Always on**" algorithm is selected, the "Сharging signals" and the "Allow charging" signals are always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals:451 +If the "**Always on**" algorithm is selected, the "Сharging signals" and the "Allow charging" signals are always set. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals: 452 452 453 453 * Service reset; 454 454 * Power down request; ... ... @@ -464,11 +464,11 @@ 464 464 When the "**On charge request**" algorithm selected, the control is performed as follows: 465 465 466 466 * If there is a signal “Charge request” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the "Charging" and the "Allow charging" signal are set; 467 -* If the signal “Charge request” disappears or errors occur (see the "Errors 1, 2 ..." bitfields), the allow chargingcontactoropens and after the delay time T,,off,, thechargingcontactoropens;467 +* If the signal “Charge request” disappears or errors occur (see the "Errors 1, 2 ..." bitfields), the "Allow charging" signal is cleared and after the delay time T,,off,, the "Charging" signal is cleared; 468 468 469 469 (% class="box infomessage" %) 470 470 ((( 471 -**Note: **when errors occur in the system, the **Charg e**contactoropenseither immediately or with the delay T,,off,, (depends on the settings described below).471 +**Note: **when errors occur in the system, the **"Charing" **signal is cleared either immediately or with the delay T,,off,, (depends on the settings described below). 472 472 ))) 473 473 474 474 To change the parameters of the battery charge control algorithm, select the "Control → Charge" section: ... ... @@ -493,21 +493,21 @@ 493 493 494 494 === Discharge === 495 495 496 -The BMS Main 3 / BMS Main 2R device con trols the discharging contactor to connect battery to the load.496 +The BMS Main 3 / BMS Main 2R device connect battery to the load using the "Discharging" signal. 497 497 498 498 BMS Main 3 / BMS Main 2R supports three algorithms to control battery discharging: 499 499 500 -When the algorithm "**Always on**" is selected, the dischargingcontactoris alwaysclosed. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals:500 +When the algorithm "**Always on**" is selected, the "Discharging" signal is always set. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals: 501 501 502 502 * Service reset 503 503 * Power down request 504 504 * Inhibit discharging 505 505 506 -the dischargingcontactoropens.506 +the "Discharging" signal is cleared. 507 507 508 508 If the algorithm "**On charger disconnected**" is selected, the control is performed as follows: 509 509 510 -* if there is no signal“Charger connected”,thechargingcontactor isopenand there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, thedischarging contactor closes;510 +* if there is no “Charger connected” and "Charging" signals and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the "Discharging" contactor closes; 511 511 * If the signal “Charger connected” appears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the discharging contactor opens. 512 512 513 513 When the "**On discharge request**" algorithm selected, the control is performed as follows: