Changes for page 3.3 Control
Last modified by Admin on 2026/04/30 15:56
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -8,7 +8,7 @@ 8 8 9 9 To change the common BMS settings, select the "Control → Common settings" section: 10 10 11 -[[image:17 35054851946-552.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="105" width="800"]]11 +[[image:1777557373784-459.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="180" width="800"]] 12 12 13 13 In this section: 14 14 ... ... @@ -563,7 +563,7 @@ 563 563 On **Independent (on Charge request or Discharge request)** algorithm "Charging/Discharging" signal is based on its own controller and performs as follows: 564 564 565 565 * if there is "Charge request" or "Discharge request" signal and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the Charging/Discharging signal is set; 566 -* If the "Charge request" or"Discharge request" disappears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the "Charging/Discharging" signal is cleared.566 +* If the "Charge request" and "Discharge request" disappears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the "Charging/Discharging" signal is cleared. 567 567 568 568 (% class="box infomessage" %) 569 569 ((( ... ... @@ -584,7 +584,7 @@ 584 584 * **Delay before starting charging or discharging**, millisecond; 585 585 * **Delay before stopping charging or discharging**, millisecond; 586 586 * **Control the precharging contactor** – a flag that enables control of precharging contactor while closing the charge/discharge contactor; 587 -* **Emulate the "Charging" and "Discharging" signals** – a flag to enable generation of "Charging" and "Discharging" signals when closing charge/discharge contactor. DO NOT use with enabled Chargerand Disc;587 +* **Emulate the "Charging" and "Discharging" signals** – a flag to enable generation of "Charging" and "Discharging" signals in Independet mode when closing Charge/Discharge contactor. **DO NOT** use with enabled Charge and Discharge controllers; 588 588 * **Errors 1, 2 to prevent CHARGING through charging/discharging contactor, Errors 1, 2 to prevent DISCHARGING through charging/discharging contactor** – bitfields to choose the errors which will open the charging/discharging contactor. This bitfields are combined by bitwise OR and intended to separate settings for charging and discharging processes; 589 589 * **Errors 1, 2 which affect the contactor only if battery CHARGING is detected** – a bitfield to choose the errors which will trigger only if charging current is present. This bitfield is combined with "Errors 1, 2 to prevent CHARGING through charging/discharging contactor" by bitwise AND; 590 590 * **Errors 1, 2 which affect the contactor only if battery DISCHARGING is detected** – a bitfield to choose the errors which will trigger only if discharging current is present. This bitfield is combined with "Errors 1, 2 to prevent DISCHARGING through charging/discharging contactor" by bitwise AND;
- 1777557373784-459.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +40.4 KB - Content
- 1777557391157-274.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +40.4 KB - Content