Changes for page 3.3 Control
Last modified by Admin on 2026/04/30 15:56
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -373,9 +373,9 @@ 373 373 374 374 (% class="box infomessage" %) 375 375 ((( 376 -**Note:** The **"Allow charging"**signal activates under two independent conditions:376 +**Note:** The "Allow charging" signal activates under two independent conditions: 377 377 1) the voltage on the cells reaches the “Voltage to reset the “Ready to charge"” level and 378 -2) the "Delay before recharging" time has passed since the clearing of the"Allow charging"signal.378 +2) the "Delay before recharging" time has passed since the opening of the allow charging contactor. 379 379 ))) 380 380 381 381 === Discharging status === ... ... @@ -454,17 +454,17 @@ 454 454 * Power down request; 455 455 * Inhibit charging, 456 456 457 - the"Charging" signal is cleared.457 +"Charging" signal is cleared. 458 458 459 459 When the algorithm "**On charger connected**" is selected, the control is performed as follows: 460 460 461 -* If there is a signal “Charger connected” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the "Charging" signal isset;462 -* If the signal “Charger connected” disappears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the "Charging" signal is cleared. 461 +* If there is a signal “Charger connected” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the "Charging" signal are set; 462 +* If the signal “Charger connected” disappears or errors occur (see the "Errors 1, 2 ..." bitfields), the "Allow charging" signal is cleared and after the delay time T,,off,, the "Charging" signal is cleared. 463 463 464 464 When the "**On charge request**" algorithm selected, the control is performed as follows: 465 465 466 -* If there is a signal “Charge request” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the "Charging" signal isset;467 -* If the signal “Charge request” disappears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the "Charging" signal is cleared; 466 +* If there is a signal “Charge request” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the "Charging" and the "Allow charging" signal are set; 467 +* If the signal “Charge request” disappears or errors occur (see the "Errors 1, 2 ..." bitfields), the "Allow charging" signal is cleared and after the delay time T,,off,, the "Charging" signal is cleared; 468 468 469 469 (% class="box infomessage" %) 470 470 ((( ... ... @@ -513,11 +513,11 @@ 513 513 When the "**On discharge request**" algorithm selected, the control is performed as follows: 514 514 515 515 * if there is signal “Discharge request” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the "Discharging" signal is set; 516 -* If the signal “Discharge request” disappears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the "Discharging"signal iscleared.516 +* If the signal “Discharge request” disappears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the discharging contactor opens. 517 517 518 518 (% class="box infomessage" %) 519 519 ((( 520 -**Note: **when errors occur in the system, the ** "Discharge"**signal isclearedeither immediately or with the delay T,,off,, (depends on the settings described below).520 +**Note: **when errors occur in the system, the **Discharge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 521 521 ))) 522 522 523 523 To change the parameters of the battery discharge control algorithm, select the "Control → Discharge" section: ... ... @@ -542,16 +542,16 @@ 542 542 543 543 === Charge/Discharge === 544 544 545 -The BMS Main 3 / BMS Main 2R device can control the contactor, usedinpower lineboth usedforconnecting batteryto chargerandload, by using the "Charging/Discharging"signal.545 +The BMS Main 3 / BMS Main 2R device can control the Charge/Discharge contactor, which combines algorithms of charging and discharging contactor. 546 546 547 - "Charging/Discharging"signalhas three algorithms of operation:547 +Charge/Discharge contactor has three algorithms of operation: 548 548 549 -On **Dependent (on Charging and Discharging signals)** algorithm the "Charging/Discharging"signaldepends on Charge and Discharge controllers and equal to:549 +On **Dependent (on Charging and Discharging signals)** algorithm the charge/discharge contactor depends on Charge and Discharge controllers and behaves: 550 550 551 -* "Charging"signalif "Charging" signal is set;552 -* "Discharging"signalin other cases.551 +* as Charging contactor if "Charging" signal is set; 552 +* as Discharging contactor in other cases. 553 553 554 -When **Independent (Always) **algorithm is selected, the Charging/discharging contactor is always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals:554 +When **Independent (Always) **algorithm is selected, the charging/discharging contactor is always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals: 555 555 556 556 * Service reset 557 557 * Power down request