Changes for page 3.3 Control
Last modified by Admin on 2026/04/30 15:56
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -542,16 +542,16 @@ 542 542 543 543 === Charge/Discharge === 544 544 545 -The BMS Main 3 / BMS Main 2R device can control the contactor used in power line both used fora sdfcharging and545 +The BMS Main 3 / BMS Main 2R device can control the contactor, used in power line both used for connecting battery to charger and load, by using the "Charging/Discharging" signal. 546 546 547 -Charg e/Dischargecontactorhas three algorithms of operation:547 +"Charging/Discharging" signal has three algorithms of operation: 548 548 549 -On **Dependent (on Charging and Discharging signals)** algorithm the charge/dischargecontactordepends on Charge and Discharge controllers andbehaves:549 +On **Dependent (on Charging and Discharging signals)** algorithm the "Charging/Discharging" signal depends on Charge and Discharge controllers and equal to: 550 550 551 -* asChargingcontactorif "Charging" signal is set;552 -* asDischargingcontactorin other cases.551 +* "Charging" signal if "Charging" signal is set; 552 +* "Discharging" signal in other cases. 553 553 554 -When **Independent (Always) **algorithm is selected, the charging/discharging contactor is always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals:554 +When **Independent (Always) **algorithm is selected, the Charging/discharging contactor is always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals: 555 555 556 556 * Service reset 557 557 * Power down request