Changes for page 3.3 Control
Last modified by Admin on 2026/04/30 15:56
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -94,7 +94,7 @@ 94 94 95 95 === SOH estimation === 96 96 97 -The BMS Main 3 / BMS Main 2Rdevice calculates the state of health of the battery (SOH) using two algorithms:97 +The BMS Main 3 device calculates the state of health of the battery (SOH) using two algorithms: 98 98 99 99 In **"By effective capacity" **mode SOH is calculated as a ratio of effective capacity to nominal capacity. Effective capacity is estimated to DOD value when battery SOC reaches 0%, so SOH is recalculated each full battery discharge. 100 100 ... ... @@ -402,9 +402,9 @@ 402 402 403 403 The BMS Main 3 / BMS Main 2R device can control the precharge contactor. The precharge contactor is used to charge the intermediate capacity with low current and usually placed with the limiting resistor in parallel to charging or discharging contactor. 404 404 405 -BMS Main 3 can checkthe preachargeprocessby monitoring **the current and voltage difference** before and after contactors.405 +BMS Main 3 can detect errors while pre-charging the load capacity by monitoring **the current and voltage difference** before and after contactors. 406 406 407 -BMS Main 2R can checkthe preachargeprocess**only by monitoring the current**.407 +BMS Main 2R can detect errors while pre-charging the load capacity **only by monitoring the current**. 408 408 409 409 In **simple **mode precharge contactor closes a "Precharge time" before the closing of Charge or Discharge contactors and opens after the same amount of time after closing them. 410 410 ... ... @@ -431,7 +431,7 @@ 431 431 * **Delay before clearing the "Precharge error"**, second; 432 432 * **Lock the "Precharge error"** – a flag to block the error until the device is restarted. 433 433 434 -“Precharge error” generat es if any of the following is true:434 +“Precharge error” generation conditions if any of the following is true: 435 435 436 436 * the precharge current does not decrease during the "Precharge time" after "Number of precharging attempts"; 437 437 * voltages before and after contactors are not equal during the "Precharge time" after "Number of precharging attempts";