... ... @@ -39,7 +39,7 @@
39 39  
40 40  === SOC estimation ===
41 41  
42 -The BMS Main 3 / BMS Main 2R device calculates the state of charge (SOC) of each cell, and then the overall battery SOC, by using following algorithms:
42 +The BMS Main 3 / BMS Main 2R device calculates the state of charge (SOC) of each cell by using following algorithms:
43 43  
44 44  The **“Voltage”** SOC calculation algorithm calculates cells SOC based on the tabular dependence Uocv = Uocv(SOC, t °C).
45 45  
... ... @@ -94,7 +94,7 @@
94 94  
95 95  === SOH estimation ===
96 96  
97 -The BMS Main 3 device calculates the state of health of the battery (SOH) using two algorithms:
97 +The BMS Main 3 / BMS Main 2R device calculates the state of health of the battery (SOH) using two algorithms:
98 98  
99 99  In **"By effective capacity" **mode SOH is calculated as a ratio of effective capacity to nominal capacity. Effective capacity is estimated to DOD value when battery SOC reaches 0%, so SOH is recalculated each full battery discharge.
100 100