Changes for page 3.3 Control
Last modified by Admin on 2026/04/30 15:56
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -29,7 +29,7 @@ 29 29 ** **Summation of cell voltages** – the overall voltage is calculated as on sum of all cells in the battery; 30 30 ** **Using voltage before contactors** – the overall voltage is estimated as voltage before contactors measured by BMS. 31 31 32 -The **"Parallel-Serial"** connection works as follows: a bunch of serial connected Logics are grouped into chains. A bunch of parallel connected chains are grouped to blocks. A bunch of serial connected blocks are grouped into string. By configuring the corresponding settings it is possible to create a complex string configuration. Current through each chain will be calculated as overallstringcurrent divided by number of chains in a block.32 +The **"Parallel-Serial"** connection works as follows: a bunch of serial connected Logics are grouped into chains. A bunch of parallel connected chains are grouped to blocks. A bunch of serial connected blocks are grouped into string. By configuring the corresponding settings it is possible to create a complex string configuration. Current through each chain will be estimated as a fraction of overall current accordingly to the number of chains in a block. 33 33 34 34 The values **“Capacity”** and **“Resistance”** are used to calculate the SOC of cells and the battery. 35 35