Changes for page 3.3 Control
Last modified by Admin on 2026/04/30 15:56
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -626,9 +626,9 @@ 626 626 627 627 The following **balancing rules** are supported: 628 628 629 -* **Balance on charge** – perform balancingwhen the battery is charging (current I > 0) and time after until the battery is relaxed;630 -* **Balance on charge or relaxed** – perform balancingwhen the battery is charging (current I > 0) or when the battery is in a state of relaxation;631 -* **always**(regardless of battery state).629 +* when the battery is charging (current I > 0) and time after until the battery is relaxed; 630 +* when the battery is charging (current I > 0) or when the battery is in a state of relaxation; 631 +* always (regardless of battery state). 632 632 633 633 A balancing resistor is connected to the cell if the following conditions are simultaneously met: 634 634 ... ... @@ -741,12 +741,11 @@ 741 741 Conditions for signal generation: 742 742 743 743 * the minimum temperature among all cells of the battery is less than the “Minimum cell temperature” value during the “Delay before starting the heater” time; 744 -* there are no errors from "Errors 1, 2..." bitfields.744 +* there are no errors from** Errors 1, 2** 745 745 746 746 Conditions for clearing the signal: 747 747 748 -* the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before stopping the heater” time; 749 -* there is an error from "Errors 1, 2..." bitfields. 748 +* the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before stopping the heater” time. 750 750 751 751 (% class="box infomessage" %) 752 752 ((( ... ... @@ -761,24 +761,22 @@ 761 761 762 762 In this section: 763 763 764 -* **Enable**– a flag to enable the cooler control;765 -* **Maximum cell temperature**, °C;766 -* **Tolerant cell temperature**, °C;767 -* **Delay before starting the cooler**, millisecond;768 -* **Delay before stopping the cooler**, millisecond;769 -* **Errors 1, 2toopenthe cooler**– bitfieldstochoosethe errorswhich willopenthecooler.763 +* Enable – a flag to enable the cooler control; 764 +* Maximum cell temperature, °C; 765 +* Tolerant cell temperature, °C; 766 +* Delay before starting the cooler, millisecond; 767 +* Delay before stopping the cooler, millisecond; 768 +* Switch off the cooler contactor on errors (Undervoltage, Overcurrent, Low temperature, Short circuit or Critical error). 770 770 771 771 As a result of operating the cooling algorithm, the "Cooler" signal is generated. 772 772 773 773 Conditions for signal generation: 774 774 775 -* the maximum temperature among all cells of the battery is greater than the “Maximum cell temperature” value during the “Delay before starting the cooler” time; 776 -* there are no errors from "Errors 1, 2..." bitfields. 774 +* the maximum temperature among all cells of the battery is greater than the “Maximum cell temperature” value during the “Delay before starting the cooler” time. 777 777 778 778 Conditions for clearing the signal: 779 779 780 -* the maximum temperature among all cells of the battery is less than the “Tolerant cell temperature” value during the “Delay before stopping the cooler” time; 781 -* there is an error from "Errors 1, 2..." bitfields. 778 +* the maximum temperature among all cells of the battery is less than the “Tolerant cell temperature” value during the “Delay before stopping the cooler” time. 782 782 783 783 (% class="box infomessage" %) 784 784 ((( ... ... @@ -787,11 +787,6 @@ 787 787 788 788 === High voltage === 789 789 790 -(% class="box warningmessage" %) 791 -((( 792 -This section is not available on BMS Main 2R. 793 -))) 794 - 795 795 The BMS Main 3 device has an ability to measure high voltages before and after contactors. 796 796 797 797 To change the parameters of high voltage fault, select the "Control → High voltage" section: ... ... @@ -800,9 +800,9 @@ 800 800 801 801 In this section: 802 802 803 -* **Enable**– a flag to enable High voltage control;804 -* **Delay before clearing the High voltage fault**, second;805 -* **Lock the High voltage fault**.795 +* Enable – a flag to enable High voltage control; 796 +* Delay before clearing the High voltage fault, second; 797 +* Lock the High voltage fault. 806 806 807 807 The BMS Main 3 implements a self-diagnostics of high-voltage measurement lines. If measurement line breaks or high-voltage polarity is wrong, “High voltage fault” is generated. 808 808 ... ... @@ -815,7 +815,7 @@ 815 815 816 816 The battery discharge characteristic – the dependence Uocv = Uocv(DOD) – is used to determine the tabular dependence Uocv = Uocv(SOC, t°C), which is necessary for calculating the battery charge level. 817 817 818 -The BMS Main 3 / BMS Main 2Rdevice can automatically determine the battery discharge characteristic.810 +The BMS Main 3 device can automatically determine the battery discharge characteristic. 819 819 820 820 Before starting the process of determining the discharge characteristic, it is necessary to prepare a BMS: 821 821 ... ... @@ -828,14 +828,18 @@ 828 828 829 829 In this section: 830 830 831 -* **Enable**– a flag to enable cell analysis;832 -* **Discharge step**, Ah;833 -* **Delta voltage**– a maximum allowable voltage drop for the cell, V;834 -* **Logic index, Cell index**– a position of the analyzed cell;835 -* **Analyse the most discharged cell**– a flag to analyse of the least charged cell (in this case, the values “Logic index” and “Cell index” are ignored).823 +* Enable – a flag to enable cell analysis; 824 +* Discharge step, Ah; 825 +* Delta voltage – a maximum allowable voltage drop for the cell, V; 826 +* Logic index, Cell index – a position of the analyzed cell; 827 +* Analyse the most discharged cell – a flag to analyse of the least charged cell (in this case, the values “Logic index” and “Cell index” are ignored). 836 836 837 -Discharge step should be set equal to С/21, where C is the cell capacity.829 +Discharge step should be set equal to 838 838 831 +Discharge step= С/21, 832 + 833 +where C is the cell capacity. 834 + 839 839 The discharge characteristic will be constructed for the given cell (its position is determined by the fields “Logic index” and “Cell index”). 840 840 841 841 The algorithm for determining the discharge characteristic of the battery will be started if the “Enable” flag is set. From this moment, the control of the discharge contactor is performed by this algorithm.