Changes for page 3.3 Control
Last modified by Admin on 2026/04/30 15:56
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -626,9 +626,9 @@ 626 626 627 627 The following **balancing rules** are supported: 628 628 629 -* when the battery is charging (current I > 0) and time after until the battery is relaxed; 630 -* when the battery is charging (current I > 0) or when the battery is in a state of relaxation; 631 -* always (regardless of battery state).629 +* **Balance on charge** – perform balancing when the battery is charging (current I > 0) and time after until the battery is relaxed; 630 +* **Balance on charge or relaxed** – perform balancing when the battery is charging (current I > 0) or when the battery is in a state of relaxation ; 631 +* **Balance always** regardless of battery state. 632 632 633 633 A balancing resistor is connected to the cell if the following conditions are simultaneously met: 634 634 ... ... @@ -645,9 +645,9 @@ 645 645 If the “High logic temperature” occurs, then the balancing of the cells connected to the overheated BMS Logic device will not be performed. 646 646 ))) 647 647 648 -The BMS Main 3 / BMS Main 2R can enable the cell balancing by the external “Balancing request” signal. Balancing process will be started to cells which the voltage is higher than the balancing start voltage and the difference between the cell voltage and the minimum voltage among all the cells is greater than the balancing stop threshold. 648 +The BMS Main 3 / BMS Main 2R can enable the cell balancing by the external **“Balancing request”** signal. Balancing process will be started to cells which the voltage is higher than the balancing start voltage and the difference between the cell voltage and the minimum voltage among all the cells is greater than the balancing stop threshold. 649 649 650 -BMS Main 3 / BMS Main 2R can force a cellbalancing, if its voltage is higher than estimated value.650 +BMS Main 3 / BMS Main 2R can **force balancing **of the cell, if its voltage is higher than estimated value. 651 651 652 652 To change the cell balancing parameters, select the "Control → Cell balancing" section: 653 653 ... ... @@ -707,7 +707,7 @@ 707 707 * the battery voltage is below the minimum level; 708 708 * the “Charger connected” signal is cleared for 60 seconds. 709 709 710 -The BMS Main 3 device also shuts down the battery if it stays in the “Charging OFF”, “Discharging OFF”, “Relaxed (after charging)” or “Relaxed (after discharging)” for the configuredtime.710 +The BMS Main 3 device also shuts down the battery if it stays in the “Charging OFF”, “Discharging OFF”, “Relaxed (after charging)” or “Relaxed (after discharging)” for the the time. 711 711 712 712 To change the parameters of the power down control, select the "Control → Power down" section: 713 713