... ... @@ -787,10 +787,6 @@
787 787  
788 788  === High voltage ===
789 789  
790 -(% class="box warningmessage" %)
791 -(((
792 -This section is not available on BMS Main 2R.
793 -)))
794 794  
795 795  The BMS Main 3 device has an ability to measure high voltages before and after contactors.
796 796  
... ... @@ -800,9 +800,9 @@
800 800  
801 801  In this section:
802 802  
803 -* **Enable **– a flag to enable High voltage control;
804 -* **Delay before clearing the High voltage fault**, second;
805 -* **Lock the High voltage fault**.
799 +* Enable – a flag to enable High voltage control;
800 +* Delay before clearing the High voltage fault, second;
801 +* Lock the High voltage fault.
806 806  
807 807  The BMS Main 3 implements a self-diagnostics of high-voltage measurement lines. If measurement line breaks or high-voltage polarity is wrong, “High voltage fault” is generated.
808 808  
... ... @@ -815,7 +815,7 @@
815 815  
816 816  The battery discharge characteristic – the dependence Uocv = Uocv(DOD) – is used to determine the tabular dependence Uocv = Uocv(SOC, t°C), which is necessary for calculating the battery charge level.
817 817  
818 -The BMS Main 3 / BMS Main 2R device can automatically determine the battery discharge characteristic.
814 +The BMS Main 3 device can automatically determine the battery discharge characteristic.
819 819  
820 820  Before starting the process of determining the discharge characteristic, it is necessary to prepare a BMS:
821 821  
... ... @@ -828,14 +828,18 @@
828 828  
829 829  In this section:
830 830  
831 -* **Enable **– a flag to enable cell analysis;
832 -* **Discharge step**, Ah;
833 -* **Delta voltage** – a maximum allowable voltage drop for the cell, V;
834 -* **Logic index, Cell index** – a position of the analyzed cell;
835 -* **Analyse the most discharged cell** – a flag to analyse of the least charged cell (in this case, the values “Logic index” and “Cell index” are ignored).
827 +* Enable – a flag to enable cell analysis;
828 +* Discharge step, Ah;
829 +* Delta voltage – a maximum allowable voltage drop for the cell, V;
830 +* Logic index, Cell index – a position of the analyzed cell;
831 +* Analyse the most discharged cell – a flag to analyse of the least charged cell (in this case, the values “Logic index” and “Cell index” are ignored).
836 836  
837 -Discharge step should be set equal to С/21, where C is the cell capacity.
833 +Discharge step should be set equal to
838 838  
835 +Discharge step= С/21,
836 +
837 +where C is the cell capacity.
838 +
839 839  The discharge characteristic will be constructed for the given cell (its position is determined by the fields “Logic index” and “Cell index”).
840 840  
841 841  The algorithm for determining the discharge characteristic of the battery will be started if the “Enable” flag is set. From this moment, the control of the discharge contactor is performed by this algorithm.