Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 15 added, 0 removed)
- 1735063563460-549.png
- 1735064038329-836.png
- 1735064362593-844.png
- 1735064399985-526.png
- 1735064434321-430.png
- 1735064454708-345.png
- 1735064488658-863.png
- 1735064583408-498.png
- 1735064935499-941.png
- 1735064980481-209.png
- 1735065073836-743.png
- 1735065666891-686.png
- 1735065702806-422.png
- 1735066190419-838.png
- 1735122153011-166.png
Details
- Page properties
-
- Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Settings=2 += Configuration = 3 3 4 4 (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 5 == Control == ... ... @@ -21,7 +21,7 @@ 21 21 ** Summation of cell voltages – the overall voltage is calculated as on sum of all cells in the battery; 22 22 ** Using voltage before contactors – the overall voltage is estimated as voltage before contactors measured by BMS. 23 23 24 -The values “Capacity” ,“Resistance”,“Cycles”are used to calculate the SOC of cells and the battery.24 +The values “Capacity” and “Resistance” are used to calculate the SOC of cells and the battery. 25 25 26 26 The values of “Relax time” are used to determine the state of the battery. If the battery is in a state of relaxation, the system recalculates the voltage on the cells to the state of charge of the battery. 27 27 ... ... @@ -44,8 +44,9 @@ 44 44 45 45 To change the estimation algorithm for calculating the battery SOC, select the "Control → SOC estimation → Algorithm" section: 46 46 47 -[[image:1733322611549-423.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="148" width="800"]] 48 48 48 +[[image:1735056107942-306.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="141" width="800"]] 49 + 49 49 The following estimation algorithms supported: 50 50 51 51 * Voltage – by open circuit voltage; ... ... @@ -69,7 +69,8 @@ 69 69 70 70 * Minimal SOC – the battery SOC is assumed to be the minimum SOC among the cells; 71 71 * Average SOC – the battery SOC is taken equal to the arithmetic average of the cell SOC; 72 -* Min-Max SOC – the battery SOC is taken based on the minimum and maximum SOC of the cells (recommended method). 73 +* Min-Max SOC – the battery SOC is calculated based on the minimum and maximum SOC of the cells. Final SOC will be a) 100% if any cell has 100% SOC, b) 0% if any cell has 0% SOC; 74 +* Max-Min SOC – the battery SOC is calculated based on the minimum and maximum SOC of the cells. Final SOC will be a) 100% if all cells have 100% SOC, b) 0% if all cells have 0% SOC. 73 73 74 74 Other parameters: 75 75 ... ... @@ -104,18 +104,26 @@ 104 104 105 105 Calculation of the resistance of cells is carried out in two ways. The first method is used when the battery passes from a relaxation state to a charge or discharge state, wherein the cell resistance value 106 106 107 -R = (U-U,,ocv,,) / I,,stable,,, 109 +{{formula fontSize="SMALL" imageType="PNG"}} 110 +R = \frac{U-U_{ocv}}{I_{stable}} 111 +{{/formula}} 108 108 109 -where U isthe cell voltage measured in the charge or discharge state, V; U,,ocv,,is thecell voltage measured in the state of relaxation (before switching to the state of charge or discharge); I,,stable,,–stabilized current through the cell in the state of charge or discharge.113 +where U — the cell voltage measured in the charge or discharge state, V; U,,ocv,, — cell voltage measured in the state of relaxation (before switching to the state of charge or discharge); I,,stable,, — stabilized current through the cell in the state of charge or discharge. 110 110 111 111 The second method is used for a stepwise change in the current through the cell, while the value of the cell resistance: 112 112 113 -R = (U,,2,,-U,,1,,) / (I,,stable2,,-I,,stable1,,) provided that | I,,stable2,,-I,,stable1,, | > 0.2 × Q,,max,, 117 +{{formula fontSize="SMALL"}} 118 +R = \frac{U_2-U_1}{I_{stable2}-I_{stable1}} 119 +{{/formula}} 114 114 115 - (Q,,max,,isthe maximum cell capacity),121 +provided that 116 116 117 -where U,,2,, is the voltage on the cell at the moment when the stabilized current I,,stable2,, is flowing through it; U,,1,, – the voltage on the cell at the moment when the stabilized current I,,stable1,, flowing through it. 123 +{{formula fontSize="SMALL"}} 124 +| I_{stable2}-I_{stable1} | > 0.2 × Qmax 125 +{{/formula}} 118 118 127 +where Q,,max,, — the maximum cell capacity,U,,2,, — voltage on the cell at the moment when the stabilized current I,,stable2,, is flowing through it; U,,1,, — the voltage on the cell at the moment when the stabilized current I,,stable1,, flowing through it. 128 + 119 119 The stabilized current I,,stable,, = I, if during the stabilization time the instantaneous current I is in the range from 0.95 × I to 1.05 × I. 120 120 121 121 To change parameters of the algorithm for calculating the cell resistance, select the "Control → Resistance estimation" section: ... ... @@ -130,7 +130,7 @@ 130 130 * Minimum SOC – minimum cell SOC value for resistance calculation; 131 131 * Maximum SOC – maximum cell SOC value for resistance calculation. 132 132 133 -The calculated resistance is accepted by the system as valid (and therefore updated) if its value is in the range from Resistance/2 to “Maximum resistance factor” × Resistance, where "Resistance" is the nominal resistance of the cell (see [[Common settings>>doc:||anchor="HCommonsettings"]]). If the calculated resistance value is greater than the value (Maximum resistance factor × Resistance), the updated resistance value will be equal to the value (Maximum resistance factor × Resistance). 143 +The calculated resistance is accepted by the system as valid (and therefore updated) if its value is in the range from Resistance / 2 to “Maximum resistance factor” × Resistance, where "Resistance" is the nominal resistance of the cell (see [[Common settings>>doc:||anchor="HCommonsettings"]]). If the calculated resistance value is greater than the value (Maximum resistance factor × Resistance), the updated resistance value will be equal to the value (Maximum resistance factor × Resistance). 134 134 135 135 === Low SOC (signal) === 136 136 ... ... @@ -155,7 +155,10 @@ 155 155 156 156 * the battery SOC is greater than the “Tolerant SOC” during the “Delay before clearing the signal” time. 157 157 168 +(% class="box infomessage" %) 169 +((( 158 158 The "Low SOC signal" is indicative and can be output to a discrete output or a power switch. 171 +))) 159 159 160 160 === High charging current (signal) === 161 161 ... ... @@ -180,7 +180,10 @@ 180 180 181 181 * the measured current is less than the “Tolerant charging current” value during the “Delay before clearing the signal” time. 182 182 196 +(% class="box infomessage" %) 197 +((( 183 183 The "High charging current" signal is indicative and can be output to a discrete output or a power switch. 199 +))) 184 184 185 185 === Charge map === 186 186 ... ... @@ -190,7 +190,7 @@ 190 190 191 191 To configure parameters for determining the charge current limit, select the "Control → Charge map" section: 192 192 193 -[[image:173 3322637793-171.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="177" width="800"]]209 +[[image:1735064362593-844.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="800"]] 194 194 195 195 In this section: 196 196 ... ... @@ -197,18 +197,18 @@ 197 197 * Enable – a flag to start calculation of the charge current limit; 198 198 * Maximum charge current – a maximum allowable value of the charge current (under normal conditions), A; 199 199 * Rate of change – a rate of change the current limit to a new value (0 is for immediate change), A/s; 200 -* Option 1: Limit charge current by the battery SOC and temperature – a flag to enable correction of maximum allowable charging current 216 +* Option 1: Limit charge current by the battery SOC and temperature – a flag to enable correction of maximum allowable charging current** Kcs** depending on SOC and battery temperature; 201 201 * Option 1: SOC x Temperature x Factor – the dependence of the correction factor on SOC and battery temperature; 202 -* Option 2: Limit charge current by the contactor temperature – a flag to enable correction of maximum allowable charging current Kcc depending on contactor temperature; 218 +* Option 2: Limit charge current by the contactor temperature – a flag to enable correction of maximum allowable charging current **Kcc** depending on contactor temperature; 203 203 * Option 2: Contactor temperature x Factor – the dependence of the correction factor on SOC and contactor temperature; 204 -* Option 3: Limit charge current by the maximum cell voltage - a flag to enable correction of maximum allowable charging current Kcv depending on maximum cell voltage ;220 +* Option 3: Limit charge current by the maximum cell voltage - a flag to enable correction of maximum allowable charging current **Kcv** depending on __the maximum cell U,,ocv,, voltage__ (corrected due to current and cell resistance) 205 205 * Option 3: Cell voltage x Factor – the dependence of the correction factor on maximum cell voltage; 206 -* Option 4: Limit charge current by the cell temperature - a flag to enable correction of maximum allowable charging current Kct depending on maximum cell temperature; 222 +* Option 4: Limit charge current by the cell temperature - a flag to enable correction of maximum allowable charging current **Kct** depending on maximum cell temperature; 207 207 * Option 4: Cell temperature x Factor – the dependence of the correction factor on maximum cell temperature. 208 208 209 209 Value of the charge current limit at given SOC, temperature, contactors temperature, maximum cell voltage and maximum cell temperature is calculated as follows: 210 210 211 -Charg ingcurrent limit = Maximum chargingcurrent × Kcs × Kcc × Kcv × Kct227 +**Charge current limit = Maximum charge current × Kcs × Kcc × Kcv × Kct** 212 212 213 213 === Discharge map === 214 214 ... ... @@ -218,7 +218,7 @@ 218 218 219 219 To configure parameters for determining the discharge current limit, select the "Control → Discharge map" section: 220 220 221 -[[image:173 3322637795-310.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="178" width="800"]]237 +[[image:1735064399985-526.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="152" width="800"]] 222 222 223 223 In this section: 224 224 ... ... @@ -225,18 +225,18 @@ 225 225 * Enable – a flag to start calculation of the discharge current limit; 226 226 * Maximum discharge current – a maximum allowable value of the discharge current (under normal conditions), A; 227 227 * Rate of change – a rate of change the current limit to a new value (0 is for immediate change), A/s; 228 -* Option 1: Limit discharging current by the battery SOC and temperature – a flag to enable correction of maximum allowable discharging current Kds depending on SOC and temperature; 244 +* Option 1: Limit discharging current by the battery SOC and temperature – a flag to enable correction of maximum allowable discharging current **Kds **depending on SOC and temperature; 229 229 * Option 1: SOC x Temperature x Factor – the dependence of the correction factor on SOC and battery temperature; 230 -* Option 2: Limit discharge current by the contactor temperature – a flag to enable correction of maximum allowable discharging current Kdc depending on contactor temperature; 246 +* Option 2: Limit discharge current by the contactor temperature – a flag to enable correction of maximum allowable discharging current **Kdc** depending on contactor temperature; 231 231 * Option 2: Contactor temperature x Factor – the dependence of the correction factor on SOC and contactor temperature; 232 -* Option 3: Limit discharge current by the cell voltage - a flag to enable correction of maximum allowable discharging current Kdv depending on minimum cell voltage ;248 +* Option 3: Limit discharge current by the cell voltage - a flag to enable correction of maximum allowable discharging current **Kdv** depending on __the minimum cell U,,ocv,, voltage__ (corrected due to current and cell resistance) 233 233 * Option 3: Cell voltage x Factor – the dependence of the correction factor on minimum cell voltage; 234 -* Option 4: Limit discharge current by the cell temperature - a flag to enable correction of maximum allowable discharging current Kdt depending on maximum cell temperature; 250 +* Option 4: Limit discharge current by the cell temperature - a flag to enable correction of maximum allowable discharging current **Kdt** depending on maximum cell temperature; 235 235 * Option 4: Cell voltage x Factor – the dependence of the correction factor on minimum cell temperature. 236 236 237 237 Value of the discharge current limit at given SOC, temperature, contactors temperature, minimum cell voltage and maximum cell temperature is calculated as follows: 238 238 239 -Discharg ingcurrent limit = Maximum dischargingcurrent × Kds × Kdc × Kdv × Kdt255 +**Discharge current limit = Maximum discharge current × Kds × Kdc × Kdv × Kdt** 240 240 241 241 === Charge map (PEAK & CONTINUOUS) === 242 242 ... ... @@ -244,7 +244,7 @@ 244 244 245 245 To configure parameters for determining the charge current limit, select the "Control → Charge map (PEAK & CONTINUOUS)" section: 246 246 247 -[[image:173332 2637796-187.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="145" width="800"]]263 +[[image:1735064434321-430.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="124" width="800"]] 248 248 249 249 In this section: 250 250 ... ... @@ -265,7 +265,6 @@ 265 265 266 266 I,,continuous,, = Maximum CONTINUOUS charge current × K,,cc,, 267 267 268 - 269 269 === Discharge map (PEAK & CONTINUOUS) === 270 270 271 271 The BMS Main 3 has an alternative algorithm for the maximum allowed discharging current based on peak and continuous battery operating modes. ... ... @@ -272,7 +272,7 @@ 272 272 273 273 To configure parameters for determining the discharge current limit, select the "Control → Discharge map (PEAK & CONTINUOUS)" section: 274 274 275 -[[image:173 3322735595-661.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="145" width="800"]]290 +[[image:1735064454708-345.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="124" width="800"]] 276 276 277 277 In this section: 278 278 ... ... @@ -293,6 +293,118 @@ 293 293 294 294 I,,continuous,, = Maximum CONTINUOUS discharge current × K,,dc,, 295 295 311 +=== Main contactor === 312 + 313 +The BMS Main 3 device controls the main contactor. The main contactor is usually placed in the common (minus) battery line for opening the charge and discharge circuits in case of sealing of the charging or discharging contactors. 314 + 315 +The Main contactor algorithm supports the following modes: 316 + 317 +* Always on; 318 +* Automatic. 319 + 320 +In “Always on” mode main contactor closes if all the following is true: 321 + 322 +* Other contactors are open; 323 +* There are no errors from the "Errors 1, 2 ..." bitfileds. 324 + 325 +In “Always on” mode main contactor opens if all the following is true: 326 + 327 +* Other contactors are open; 328 +* There is an error from the the "Errors 1, 2 ..." bitfileds. 329 + 330 +In “Automatic” mode, the main contactor closes by internal algorithms at the same time with other contactors. 331 + 332 +In “On demand” mode, the main contactor closes by external the “Close Main contactor” request. 333 + 334 +(% class="box infomessage" %) 335 +((( 336 +**Note: **when errors occur in the system, the **Main **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 337 +))) 338 + 339 +To change the parameters of the main contactor, select the "Control → Main contactor" section: 340 + 341 +[[image:1735064488658-863.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="800"]] 342 + 343 +In this section: 344 + 345 +* Enable – a flag to enable the main contactor control; 346 +* Algorithm – main contactor control algorithm: 347 +** Always on – contactor is always closed; 348 +** Automatic – contactor closes by internal charge and discharge algorithms; 349 +** On demand – contactor is closed by an external request; 350 +* Time to keep the contactor closed before closing the others – a time for other contactors to be open after the main contactor is closed; 351 +* Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, s; 352 +* Keep the contactor open until the device is restarted – a flag for keeping the main contactor open until the system is reset; 353 +* Errors 1, 2 to open the main contactor – bitfields to choose the errors which will open the main contactor. 354 + 355 +=== Charging status === 356 + 357 +To change the parameters of charging process status, select the "Control → Charging status" section: 358 + 359 +[[image:1735064935499-941.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="110" width="800"]]In this section: 360 + 361 +* Current to set the "Charging current present" – a current level to generate the "Charging current present" signal, A; 362 +* Current to clear the "Charging current present" – a current level to clear the "Charging current present" signal, A; 363 +* Voltage to clear the “Ready to charge” – a threshold voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” (hence, the “Allow charging”) signal is cleared; 364 +* Voltage to reset the “Ready to charge” – a tolerant voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” (hence, the “Allow charging”) signal is set; 365 +* Delay before recharging – a time after which the previously opened the allow charging contactor closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0; 366 +* Errors 1, 2 to clear the "Ready to charge" – bitfields to choose the errors which will clear the "Ready to charge" signal. 367 + 368 +(% class="box infomessage" %) 369 +((( 370 +**Note:** The "Allow charging" signal activates under two independent conditions: 371 +1) the voltage on the cells reaches the “Voltage to reset the “Ready to charge"” level and 372 +2) the "Delay before recharging" time has passed since the opening of the allow charging contactor. 373 +))) 374 + 375 +=== Discharging status === 376 + 377 +To change the parameters of discharging process status, select the "Control → Discharging status" section: 378 + 379 +[[image:1735064980481-209.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]In this section: 380 + 381 +* Current to set the "Discharging current present" – a current level to generate the "Discharging current present" signal, А; 382 +* Current to clear the "Discharging current present" – a current level to clear the "Discharging current present" signal, А; 383 +* Voltage to clear the “Ready to discharge” – a threshold voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 384 +* Voltage to reset the “Ready to discharge” – a tolerant voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set; 385 +* Errors 1, 2 to clear the "Ready to discharge" – bitfields to choose the errors which will clear the "Ready to discharge" signal. 386 + 387 +=== Precharge === 388 + 389 +The BMS Main 3 device can control the precharge contactor. The precharge contactor is used to charge the intermediate capacity with low current and usually placed with the limiting resistor in parallel to charging or discharging contactor. 390 + 391 +BMS Main 3 device detects errors while pre-charging the load capacity by monitoring the current and voltage difference before and after contactors. Also BMS can measure the power dissipated on precharge resistor and generate an error if it greater than configured limit. 392 + 393 +TBA 394 + 395 +To change the parameters of precharge contactor, select the "Control → Precharge" section: 396 + 397 +[[image:1735065073836-743.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="160" width="800"]] 398 + 399 +* Precharge current threshold to finish precharging – a minimum current value at which precharging process assumed to be finished, A; 400 +* Check voltages before and after contactors to finish precharging – a flag to check the voltages before and after contactors to ensure that precharge process has finished and it is allowed to close the discharging contactor; 401 +* Minimum voltage difference to finish precharging – minimal voltage difference before and after contactors at which precharge process is meant to be finished, V; 402 +* Number of precharging attempts – maximum number of precharging attempts before setting the "Precharge error"; 403 +* Precharge time – a duration of closing the precharge contactor before closing the discharging contactor, millisecond; 404 +* Relaxation between attempts – a duration between precharge attempts, millisecond; 405 +* Check the power dissipated in the preacharge resistor - a flag to enable the calculation of power dissipated in precharge resistor; 406 +* Precharge resistor resistance, Ohm; 407 +* Maximum allowable power dissipated in the resistor, W; 408 +* Delay before setting the "Precharge error" when checking power, millisecond; 409 +* Delay before clearing the "Precharge error", second; 410 +* Lock the "Precharge error" – a flag to block the error until the device is restarted. 411 + 412 +“Precharge error” generation conditions if any of the following is true: 413 + 414 +* the precharge current does not decrease during the "Precharge time" after "Number of precharging attempts"; 415 +* voltages before and after contactors are not equal during the "Precharge time" after "Number of precharging attempts"; 416 +* power dissipated on the precharge resistor is above the maximum value during the “Delay before setting the 'Precharge error' when checking power” time. 417 + 418 +(% class="box warningmessage" %) 419 +((( 420 +Behavior of contactors at “Precharge error” is configured in corresponding contactor settings! 421 +))) 422 + 296 296 === Charge === 297 297 298 298 There are two contactors that serve charging the battery: a charging contactor and an allow charging contactor. With the help of the allow charging contactor, the BMS commands the charger to start or stop charging. ... ... @@ -303,49 +303,36 @@ 303 303 * On charger connected – charging is allowed when there is a signal “Charger connected”; 304 304 * On charge request – charging is allowed when there is a signal “Charge request”. 305 305 306 -If the "**Always on**" algorithm is selected, the charging contactor and the allow charging contactor are always closed. If at least one of the errors appears: 433 +If the "**Always on**" algorithm is selected, the charging contactor and the allow charging contactor are always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals: 307 307 308 -* Overvoltage; 309 -* Overcurrent; 310 -* High temperature (CH); 311 -* Low temperature (CH); 312 -* HYG offline (optional); 313 -* Combilift offline (optional); 314 -* Spirit offline (optional); 315 -* Spirit charger error (optional); 316 -* Short circuit (optional); 317 -* High contactor temperature (optional); 318 -* CH contactor cycles error; 319 -* Precharge error (optional); 320 -* Critical error 435 +* Service reset; 436 +* Power down request; 437 +* Inhibit charging, 321 321 322 -or one of the signals: 323 - 324 -* Service reset 325 -* Power down request 326 -* Inhibit charging 327 - 328 328 both contactors are open (no current flows). 329 329 330 330 When the algorithm "**On charger connected**" is selected, the control is performed as follows: 331 331 332 -* If there is a signal “Charger connected” and there are no errors (see the listabove), then through the delay time T,,on,, the charging contactor and the allow charging contactor close;443 +* If there is a signal “Charger connected” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the charging contactor and the allow charging contactor close; 333 333 * If the signal “Charger connected” disappears, the allow charging contactor opens and after the delay time T,,off,, the charging contactor opens; 334 334 * If in the process of charging the voltage on the cell exceeds the “Ready to charge” level, the allow charging contactor opens (while the charging contactor remains closed); 335 -* If errors inthelistabove occur the charging contactor and allow charging contactor open.446 +* If errors from the "Errors 1, 2 ..." bitfields occur the charging contactor and allow charging contactor open. 336 336 337 337 When the "**On charge request**" algorithm selected, the control is performed as follows: 338 338 339 -* If there is a signal “Charge request” and there are no errors (see the listabove), then through the delay time T,,on,, the charging contactor and the allow charging contactor close;450 +* If there is a signal “Charge request” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the charging contactor and the allow charging contactor close; 340 340 * If the signal “Charge request” disappears, the allow charging contactor opens and after the delay time T,,off,, the charging contactor opens; 341 341 * If in the process of charging the voltage on the cell exceeds the “Ready to charge” level, the allow charging contactor opens (while the charging contactor remains closed); 342 -* If errors inthelistabove occur the charging contactor and allow charging contactor open.453 +* If errors from the "Errors 1, 2 ..." bitfields occur the charging contactor and allow charging contactor open. 343 343 344 -Note – When errors occur in the system, the charging contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 455 +(% class="box infomessage" %) 456 +((( 457 +**Note: **when errors occur in the system, the **Charge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 458 +))) 345 345 346 346 To change the parameters of the battery charge control algorithm, select the "Control → Charge" section: 347 347 348 -[[image:17333 22798914-813.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="327" width="800"]]462 +[[image:1735063563460-549.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="262" width="800"]] 349 349 350 350 In this section: 351 351 ... ... @@ -354,20 +354,15 @@ 354 354 ** Always on – charging is always allowed; 355 355 ** On charger connected – charging is allowed when there is a signal “Charger connected”; 356 356 ** On charge request – charging is allowed when there is a signal “Charge request”; 357 -* Current corresponding to charging – a current level to generate the "Charging current present" signal, A; 358 -* Current corresponding to no charging – a current level to clear the "Charging current present" signal, A; 471 +* Allow charging only when the "Ready to charge" signal is set – charging contactor will open if "Ready to charge" signal is cleared; 359 359 * Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond; 360 360 * Delay before stopping charging – a time delay T,,off,, before opening the charging contactor, millisecond; 474 +* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the charge contactor (see [[Precharge>>path:#HPrecharge]]); 475 +* Errors 1, 2 to open the charging contactor – bitfields to choose the errors which will open the charging contactor; 361 361 * Use custom delays before stopping charging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors; 362 -* Custom delay: <error> – specific error delay, millisecond;477 +* Custom delay: <error> – delay for specific error, millisecond; 363 363 * Switch off the charging contactor on errors without delay – a flag to protectively open the charging contactor without a delay. In the opposite case, when an error is detected, the charging contactor opens always with the delay “Delay before stopping charging”; 364 -* Control the precharging contactor – a flag that allows control of the precharging contactor; 365 -* Voltage to clear the “Ready to charge” – a threshold voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” (hence, the “Allow charging”) signal is cleared; 366 -* Voltage to reset the “Ready to charge” – a tolerant voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” (hence, the “Allow charging”) signal is set; 367 -* Delay before recharging – a time after which the previously opened the allow charging contactor closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0. 368 368 369 -Note – The allow charging contactor closes under two independent conditions: 1) the voltage on the cells reaches the “Voltage to reset the “Ready to charge"” level and 2) the "Delay before recharging" time has passed since the opening of the allow charging contactor. 370 - 371 371 === Discharge === 372 372 373 373 The device controls the discharging contactor to connect battery to the load. ... ... @@ -378,26 +378,8 @@ 378 378 * On charger disconnected – load is connected when there is no signal “Charger connected”; 379 379 * On discharge request – load is connected when there is signal “Discharge request”. 380 380 381 -When the algorithm "**Always on**" is selected, the discharging contactor is always closed. If at least one of the errors appears: 490 +When the algorithm "**Always on**" is selected, the discharging contactor is always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals: 382 382 383 -* Undervoltage; 384 -* Overvoltage (optional); 385 -* Overcurrent; 386 -* High temperature (DCH); 387 -* Low temperature (DCH) (optional); 388 -* HYG offline (optional); 389 -* Combilift offline (optional); 390 -* Spirit offline (optional); 391 -* Spirit charger error (optional); 392 -* Short circuit (optional); 393 -* High contactor temperature (optional); 394 -* Unallowable charging; 395 -* DCH contactor cycles error; 396 -* Precharge error (optional); 397 -* Critical error 398 - 399 -or one of the signals: 400 - 401 401 * Service reset 402 402 * Power down request 403 403 * Inhibit discharging ... ... @@ -406,21 +406,22 @@ 406 406 407 407 If the algorithm "**On charger disconnected**" is selected, the control is performed as follows: 408 408 409 -* if there is no signal “Charger connected”, the charging contactor is open and there are no errors (see the listabove), then through the delay time T,,on,, the discharging contactor closes;410 -* If the signal “Charger connected” appears or errors occur (see the listabove), then after the delay time T,,off,, the discharging contactor opens.500 +* if there is no signal “Charger connected”, the charging contactor is open and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the discharging contactor closes; 501 +* If the signal “Charger connected” appears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the discharging contactor opens. 411 411 412 412 When the "**On discharge request**" algorithm selected, the control is performed as follows: 413 413 414 -* if there is signal “Discharge request”, the charging contactor is open and there are no errors (see the listabove), then through the delay time T,,on,, the discharging contactor closes;415 -* If the signal “Discharge request” disappears or errors occur (see the listabove), then after the delay time T,,off,, the discharging contactor opens.505 +* if there is signal “Discharge request”, the charging contactor is open and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the discharging contactor closes; 506 +* If the signal “Discharge request” disappears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the discharging contactor opens. 416 416 417 -Note – In case of errors in the system operation, the opening of the discharging contactor is performed either immediately or with a delay T,,off,, (depends on the settings described below). 508 +(% class="box infomessage" %) 509 +((( 510 +**Note: **when errors occur in the system, the **Discharge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 511 +))) 418 418 419 -The device supports controlling the precharging contactor. The duration of switching on the precharging contactor before closing the discharging (load) contactor is adjusted. 420 - 421 421 To change the parameters of the battery discharge control algorithm, select the "Control → Discharge" section: 422 422 423 -[[image:173 3323750262-841.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="360" width="800"]]515 +[[image:1735064038329-836.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="273" width="800"]] 424 424 425 425 In this section: 426 426 ... ... @@ -429,30 +429,51 @@ 429 429 ** Always on – load is always connected; 430 430 ** On charger disconnected – load is connected when there is no signal “Charger connected”; 431 431 ** On discharge request – load is connected when there is signal “Discharge request”; 432 -* Current corresponding to discharging – a current level to generate the "Discharging current present" signal, А; 433 -* Current indicating no discharging – a current level to clear the "Discharging current present" signal, А; 524 +* Allow charging only when the "Ready to discharge" signal is set – discharging contactor will open if "Ready to discharge" signal is cleared; 434 434 * Delay before starting discharging – a time delay T,,on,, before closing the discharging contactor, millisecond; 435 435 * Delay before stopping discharging – a time delay T,,off,, before opening the discharging contactor, millisecond; 527 +* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the discharge contactor (see [[Precharge>>doc:||anchor="HPrecharge"]]); 528 +* Errors 1, 2 to open the discharging contactor – bitfields to choose the errors which will open the discharging contactor; 436 436 * Use custom delays before stopping discharging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors; 437 437 * Custom delay: <error> – specific error delay, millisecond; 438 438 * Switch off the discharging contactor on errors without delay – a flag to protectively open the discharging contactor without a delay. In the opposite case, when an error is detected, the discharging contactor opens always with the delay “Delay before stopping discharging”. 439 -* Precharge time – a duration of closing the precharge contactor before closing the discharging contactor, millisecond; 440 -* Check voltages before and after contactors to finish precharging – a flag to check the voltages before and after contactors to ensure that precharge process has finished and it is allowed to close the discharging contactor; 441 -* Minimum voltage difference to finish precharging – minimal voltage difference before and after contactors at which precharge process is meant to be finished, V; 442 -* Voltage to clear the “Ready to discharge” – a threshold voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 443 -* Voltage to reset the “Ready to discharge” – a tolerant voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set; 444 444 445 445 === Charge/Discharge === 446 446 447 -The BMS Main 3 device can control the charg ing/dischargingcontactor, which combines algorithms of charging and discharging contactor.It behaves as a charging contactor when “Charge request” or “Charger connected” is set, otherwise – as a discharging contactor.535 +The BMS Main 3 device can control the charge/discharge contactor, which combines algorithms of charging and discharging contactor. 448 448 537 +Charge/Discharge contactor has three algorithms of operation: 538 + 539 +* Dependent (on Charging and Discharging signals) - Charge/Discharge contactor depends on Charge and Discharge algorithms and their signals and behaves as Charging contactor if Charging signal is set, otherwise – as Discharging contactor; 540 +* Independent (Always) - Charge/Discharge contactor is always closed if there is no errors; 541 +* Independent (on Charge request or Discharge request) - Charge/Discharge contactor is based on its own controller that listen to Charge and Discharge requests and closes if one of these signals occurs. 542 + 543 +TBA 544 + 545 +(% class="box infomessage" %) 546 +((( 547 +**Note: **when errors occur in the system, the **Charge/Discharge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 548 +))) 549 + 449 449 The charging/discharging contactor control is configured in the “Control – Charge/Discharge” section: 450 450 451 -[[image:173 3322827919-875.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="85" width="800"]]552 +[[image:1735122153011-166.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="162" width="800"]] 452 452 453 453 In this section: 454 454 455 455 * Enable – a flag to enable the charge/discharge controller. 557 +* Algorithm: 558 +** Dependent (on Charging and Discharging signals) - Charge/Discharge contactor depends on Charge and Discharge algorithms and their signals and behaves as Charging contactor if Charging signal is set, otherwise – as Discharging contactor; 559 +** Independent (Always) - Charge/Discharge contactor is always closed if there is no errors; 560 +** Independent (on Charge request or Discharge request); 561 +* Delay before starting charging or discharging, millisecond; 562 +* Delay before stopping charging or discharging, millisecond; 563 +* Control the precharging contactor – a flag that enables control of precharging contactor while closing the charge/discharge contactor; 564 +* Emulate the "Charging" and "Discharging" signals – a flag to enable generation of "Charging" and "Discharging" signals when closing charge/discharge contactor; 565 +* Errors 1, 2 to prevent CHARGING through charging/discharging contactor, Errors 1, 2 to prevent DISCHARGING through charging/discharging contactor – bitfields to choose the errors which will open the charging/discharging contactor. This bitfields are combined by bitwise OR and intended to separate settings for charging and discharging processes; 566 +* Errors 1, 2 which affect the contactor only if battery CHARGING is detected – a bitfield to choose the errors which will trigger only if charging current is present. This bitfield is combined with "Errors 1, 2 to prevent CHARGING through charging/discharging contactor" by bitwise AND; 567 +* Errors 1, 2 which affect the contactor only if battery DISCHARGING is detected – a bitfield to choose the errors which will trigger only if discharging current is present. This bitfield is combined with "Errors 1, 2 to prevent DISCHARGING through charging/discharging contactor" by bitwise AND; 568 +* Switch off the charging/discharging contactor on errors without delay – a flag to protectively open the charging/discharging contactor without a delay. In the opposite case, when an error is detected, the charging/discharging contactor opens always with the delay “Delay before stopping discharging”. 456 456 457 457 === Discharge (AUX) === 458 458 ... ... @@ -464,11 +464,11 @@ 464 464 465 465 * the battery has low SOC; 466 466 * the battery voltage is out of range; 467 -* the battery system errors are detected.580 +* the errors are detected (configured in the "Errors 1, 2 ..." bitfields). 468 468 469 469 To change the parameters of the powering of external equipment, select the "Control → Discharge (AUX)" section: 470 470 471 -[[image:173 3322827920-878.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="130" width="800"]]584 +[[image:1735066190419-838.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="161" width="800"]] 472 472 473 473 In this section: 474 474 ... ... @@ -476,66 +476,14 @@ 476 476 * Switch off the discharging (AUX) contactor if the SOC is too low; 477 477 * Minimum SOC – a minimum SOC value, when reached, the auxiliary (AUX) discharging contactor opens, %; 478 478 * Tolerant SOC – a permissive SOC value, upon reaching which the auxiliary (AUX) discharging contactor re-closes, %; 592 +* Switch off the discharging (AUX) contactor if the cell voltage is out of the range; 593 +* Minimum cell voltage, V; 594 +* Maximum cell voltage, V; 479 479 * Switch off the discharging (AUX) contactor if the battery voltage is out of the range; 480 -* Minimum voltage – minimumbattery voltage, V;481 -* Maximum voltage – maximumbattery voltage, V;482 -* Switchoff the discharging(AUX)contactoronerrors –the auxiliary(AUX)discharging contactoropensif thefollowingerrorsoccur:Undervoltage,Overcurrent,Hightemperature(DCH), Short circuit, Critical error.596 +* Minimum battery voltage, V; 597 +* Maximum battery voltage, V; 598 +* Errors 1, 2 to open the auxiliary discharging contactor – bitfields to choose the errors which will open the auxiliary discharging contactor. 483 483 484 -=== Main contactor === 485 - 486 -The BMS Main 3 device controls the main contactor. The main contactor is usually placed in the common (minus) battery line for opening the charge and discharge circuits in case of sealing of the charging or discharging contactors. 487 - 488 -The Main contactor algorithm supports the following modes: 489 - 490 -* Always on; 491 -* Automatic; 492 -* On demand. 493 - 494 -In “Always on” mode main contactor closes if all the following is true: 495 - 496 -* Charging contactor is open; 497 -* Discharging contactor is open; 498 -* There are no errors from the list below: 499 -** Overcurrent; 500 -** Undervoltage; 501 -** Overvoltage; 502 -** High temperature (CH); 503 -** High temperature (DCH); 504 -** Unallowable charging; 505 -** Critical error. 506 - 507 -In “Always on” mode main contactor opens if all the following is true: 508 - 509 -* Charging contactor is open; 510 -* Discharging contactor is open; 511 -* There is an error from the list below: 512 -** Overcurrent; 513 -** Undervoltage; 514 -** Overvoltage; 515 -** High temperature (CH); 516 -** High temperature (DCH); 517 -** Unallowable charging; 518 -** Critical error. 519 - 520 -In “Automatic” mode, the main contactor closes by internal charging and discharging algorithms at the same time with Precharging, Charging and Discharging contactors. 521 - 522 -In “On demand” mode, the main contactor closes by external the “Close Main contactor” request. 523 - 524 -To change the parameters of the main contactor, select the "Control → Main contactor" section: 525 - 526 -[[image:1733322872744-536.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="105" width="800"]] 527 - 528 -In this section: 529 - 530 -* Enable – a flag to enable the main contactor control; 531 -* Algorithm – main contactor control algorithm: 532 -** Always on – contactor is always closed; 533 -** Automatic – contactor closes by internal charge and discharge algorithms; 534 -** On demand – contactor is closed by an external request; 535 -* Time to keep the contactor closed before closing the others – a time for other contactors to be open after the main contactor is closed; 536 -* Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, s; 537 -* Keep the contactor open until the device is restarted – a flag for keeping the main contactor open until the system is reset. 538 - 539 539 === Cell balancing === 540 540 541 541 Balancing makes the voltage of all cells equal to the minimum cell voltage. ... ... @@ -549,20 +549,25 @@ 549 549 A balancing resistor is connected to the cell if the following conditions are simultaneously met: 550 550 551 551 * the voltage on the cell is higher than the balancing start voltage; 552 -* the difference between the voltage on the cell and the minimum voltage among the battery cells is greater than the balancing start threshold .613 +* the difference between the voltage on the cell and the minimum voltage among the battery cells is greater than the balancing start threshold; 553 553 554 554 A balancing resistor is disconnected from the cell if any of the following conditions are met: 555 555 556 -* the voltage on the cell is less than the balancing st artvoltage;617 +* the voltage on the cell is less than the balancing stop voltage; 557 557 * the difference between the voltage on the cell and the minimum voltage among the battery cells is less than the balancing stop threshold. 558 558 620 +(% class="box infomessage" %) 621 +((( 559 559 If the “High logic temperature” occurs, then the balancing of the cells connected to the overheated BMS Logic device will not be performed. 623 +))) 560 560 561 561 The BMS Main 3 can enable the cell balancing by the external “Balancing request” signal. Balancing process will be started to cells which the voltage is higher than the balancing start voltage and the difference between the cell voltage and the minimum voltage among all the cells is greater than the balancing stop threshold. 562 562 627 +BMS Main 3 can force a cell balancing, if its voltage is higher than estimated value. 628 + 563 563 To change the cell balancing parameters, select the "Control → Cell balancing" section: 564 564 565 -[[image:173 3322883460-118.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="114" width="800"]]631 +[[image:1735065702806-422.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="130" width="800"]] 566 566 567 567 In this section: 568 568 ... ... @@ -571,12 +571,14 @@ 571 571 ** Balance on charge – balancing is performed while and after the charging (in the “Charge ON” and “Charge OFF” states); 572 572 ** Balance on charge or relaxed - balancing is performed while and after the charging and in the relaxed state (in “Charge ON”, “Charge OFF”, “Relaxed (after charging)” and “Relaxed (after discharging)” states); 573 573 ** Balance always – balancing is always performed regardless the battery state; 574 - 575 - [[image:1733322883462-975.png||data-xwiki-image-style-alignment="center"data-xwiki-image-style-border="true"height="74" width="600"]]576 - 640 +* Balancing condition: 641 +** Automatic – balancing will be performed automatically if needed conditions are met; 642 +** On balancing request – balancing will start only if a remote request is received. In this case cells will start to balance regardless the "Voltage deviation to start balancing" value; 577 577 * Minimum cell voltage to start balancing, V; 578 578 * Voltage deviation to start balancing; 579 579 * Voltage deviation to stop balancing; 646 +* Voltage for forced balancing – if cell voltage is above this value, it will start discharging through balancing resistor; 647 +* Maximum allowable temperature of BMS Logic devices, ºC; 580 580 * Command to discharge all cells – a flag to force the balancing of all cells. 581 581 582 582 === Series balancing === ... ... @@ -654,7 +654,10 @@ 654 654 655 655 * the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before stopping the heater” time. 656 656 657 -If there is the "Heater" signal, the heater contactor closes and/or a signal is output to the corresponding digital output. 725 +(% class="box infomessage" %) 726 +((( 727 +If there is the "Heater" signal, the heater contactor closes and/or a signal is set to the corresponding digital output. 728 +))) 658 658 659 659 === Cooler === 660 660 ... ... @@ -681,7 +681,10 @@ 681 681 682 682 * the maximum temperature among all cells of the battery is less than the “Tolerant cell temperature” value during the “Delay before stopping the cooler” time. 683 683 684 -If there is the "Cooler" signal, the cooler contactor closes and/or a signal is output to the corresponding digital output. 755 +(% class="box infomessage" %) 756 +((( 757 +If there is the "Cooler" signal, the cooler contactor closes and/or a signal is set to the corresponding digital output. 758 +))) 685 685 686 686 === High voltage === 687 687 ... ... @@ -699,7 +699,10 @@ 699 699 700 700 The BMS Main 3 implements a self-diagnostics of high-voltage measurement lines. If measurement line breaks or high-voltage polarity is wrong, “High voltage fault” is generated. 701 701 702 -**If there is the “High voltage fault”, the “Critical error” is generated and all contactors open.** 776 +(% class="box warningmessage" %) 777 +((( 778 +If there is the “High voltage fault”, **the “Critical error” is generated.** 779 +))) 703 703 704 704 === Cell analysis === 705 705
- 1735063563460-549.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +59.6 KB - Content
- 1735064038329-836.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +62.0 KB - Content
- 1735064362593-844.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +35.8 KB - Content
- 1735064399985-526.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.1 KB - Content
- 1735064434321-430.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +27.5 KB - Content
- 1735064454708-345.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +27.7 KB - Content
- 1735064488658-863.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.9 KB - Content
- 1735064583408-498.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.4 KB - Content
- 1735064935499-941.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +25.7 KB - Content
- 1735064980481-209.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.2 KB - Content
- 1735065073836-743.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +38.8 KB - Content
- 1735065666891-686.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.0 KB - Content
- 1735065702806-422.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +27.2 KB - Content
- 1735066190419-838.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +37.2 KB - Content
- 1735122153011-166.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +54.3 KB - Content