Changes for page 3.3 Control

Last modified by Admin on 2026/04/30 15:56

From version 78.4
edited by Admin
on 2026/03/31 14:28
Change comment: There is no comment for this version
To version 78.3
edited by Admin
on 2026/03/31 14:27
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -787,10 +787,6 @@
787 787  
788 788  === High voltage ===
789 789  
790 -(% class="box infomessage" %)
791 -(((
792 -This section is not available on BMS Main 2R.
793 -)))
794 794  
795 795  The BMS Main 3 device has an ability to measure high voltages before and after contactors.
796 796  
... ... @@ -800,9 +800,9 @@
800 800  
801 801  In this section:
802 802  
803 -* **Enable **– a flag to enable High voltage control;
804 -* **Delay before clearing the High voltage fault**, second;
805 -* **Lock the High voltage fault**.
799 +* Enable – a flag to enable High voltage control;
800 +* Delay before clearing the High voltage fault, second;
801 +* Lock the High voltage fault.
806 806  
807 807  The BMS Main 3 implements a self-diagnostics of high-voltage measurement lines. If measurement line breaks or high-voltage polarity is wrong, “High voltage fault” is generated.
808 808  
... ... @@ -815,7 +815,7 @@
815 815  
816 816  The battery discharge characteristic – the dependence Uocv = Uocv(DOD) – is used to determine the tabular dependence Uocv = Uocv(SOC, t°C), which is necessary for calculating the battery charge level.
817 817  
818 -The BMS Main 3 / BMS Main 2R device can automatically determine the battery discharge characteristic.
814 +The BMS Main 3 device can automatically determine the battery discharge characteristic.
819 819  
820 820  Before starting the process of determining the discharge characteristic, it is necessary to prepare a BMS:
821 821  
... ... @@ -828,14 +828,16 @@
828 828  
829 829  In this section:
830 830  
831 -* **Enable **– a flag to enable cell analysis;
832 -* **Discharge step**, Ah;
833 -* **Delta voltage** – a maximum allowable voltage drop for the cell, V;
834 -* **Logic index, Cell index** – a position of the analyzed cell;
835 -* **Analyse the most discharged cell** – a flag to analyse of the least charged cell (in this case, the values “Logic index” and “Cell index” are ignored).
827 +* Enable – a flag to enable cell analysis;
828 +* Discharge step, Ah;
829 +* Delta voltage – a maximum allowable voltage drop for the cell, V;
830 +* Logic index, Cell index – a position of the analyzed cell;
831 +* Analyse the most discharged cell – a flag to analyse of the least charged cell (in this case, the values “Logic index” and “Cell index” are ignored).
836 836  
837 -Discharge step should be set equal to С/21,
833 +Discharge step should be set equal to
838 838  